background image

 

9

   use recommended parts only. unapproved parts may be dangerous, and will invalidate your warranty.

 

8

  

do not

 operate the fan where there are explosive or flammable gases, fumes or other hazardous substances.

 

8

  

do not

 stand the fan on the power cable. 

 

8

  

do not

 insert any objects through the fan guard.

 

8

  

do not

 cover the fan when in use.

 

8

  

do not

 immerse the fan in water or any other liquid.

 

8

  

do not

 allow children to operate the fan.

 

8

  

do not

 stand the fan where it may be knocked over or off a surface, or where the lead may cause a person to trip.

 

8

  

do not

 modify speed control or attempt to fit any additional external speed control device to the fan.

 

9

   When not in use place the fan in its original box, or cover, to protect from dust and store in a safe, dry, childproof location.

 

note: this appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental 

 

capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in  

                a safe way and understand the hazards involved. children shall not play with the appliance. cleaning and user maintenance shall not  

 

be made by children without supervision.

2.  introduction

 

High velocity industrial two-speed drum fan suitable for movement of huge volumes of air. Professional belt drive motor ensures a  

 

 

smooth and quiet performance. robust unit with heavy-duty gauge steel casing, guard and frame. Handle, wheels and fully tiltable    

 

cradle allows control of airflow to exactly where it is needed. carefully balanced and fully guarded blades provided. suitable for use    

 

in industrial, commercial, agricultural, automotive workshop and showroom applications. maximum Airflow: 350mtr³/min (12,300cfm).    

 

fitted with Bs approved plug.

3.  sPecification

model no: .......................................................................................hvd42b

fanØ: ...................................................................................... 1065mm (42”)

speeds: ........................................................................................................2

speed range: .............................................................................400-450rpm

maximum Airflow: ................................................... 350mtr³/min (12,300cfm)

Power: ........................................................................................... 580-630W

supply: ...................................................................................................230V

current: ...................................................................................................2.7A

4.  oPeration

 

‰

   WArninG! ensure you read, understand and apply the safety instructions in section 1 before using the fan.

4.1.   

the fan is easily transportable by means of the wheels provided. lift by the handle (fig.2) and manoeuvre the fan into position. ensure that  

 

there is nothing in front of the fan that may be disturbed when the fan is switched on.

 

the drum can be tilted by loosening the tilt locking handles on either side of the drum, tilt the drum to the required angle and re-tighten the tilt    

 

locking handles. 

4.2.    

check that the switch situated on the side of the drum is set to “0” (fig.3). uncoil the power lead from its stowage position (fig.2) 

 

and plug into the mains power supply. ensure that the power lead is not stretched or positioned in such a way as to cause a hazard.

 

switch the power on.

4.3.    

turn the fan on by pressing the switch to either “1” or “2” (fig.3) depending on the volume of air required. 

4.4.    

After use ensure the switch is returned  “0” and disconnect the fan from mains power.

4.5.    

store the lead onto the stowage hook situated on the drum, near the lifting handle.

5.  maintenance

 

‰

 

  Warning! 

ensure that the fan is disconnected from the mains power supply before attempting any of the following:

5.1.    

use a soft, damp cloth to clean the fan.

 do not

 immerse the fan in water and never allow water to drip onto the motor housing. 

do  

 

not

 use solvents, petroleum, paint thinner or other chemicals to clean the fan.

5.2.    

to clean the fan blade, undo the bolts around the circumference, remove the grille and clean the blade with a slightly damp cloth.    

 

replace the grille as required and refit the cross headed screws.

5.3.    

should the motor, switch or the power lead require service or maintenance contact your local sealey service agent.

5.4.    

When not in use place the fan in its original box or otherwise cover to protect from dust, and store in a safe, dry, childproof location.

HVd42B | issue 2 18/01/17

Original Language Version

© Jack sealey limited

fig.1 

fig.2 

fig.3 

Reviews: