background image

The H-3000  is a portable spot welder with an electronic timer which enables precision spot welding on low carbon sheet steel ( using the standard 

arms supplied ) up to a thickness of 1+1mm. The unit also features welding pressure adjustment. The H-3000 is similar to the H-3000

2 but has additional 

features and capabilities enabling welding on low carbon sheet steel ( using the standard arms supplied ) up to a thickness of 2+2mm. The H-3000 is 

microprocessor controlled enabling the following functions to be selected from the control panel. A) Welding time. B) Welding thickness. C) Selection 

of normal or pulse welding modes. Both units are supplied with standard 120mm arms and electrodes.

 

MAIN FEATURES

 

1. Electrode pressure adjustment screw

 

2. Right / left handgrip.

 

3. Position for eyebolt. ( Eyebolt not supplied.)

 

4. Moving welding arm.

 

5. Fixed welding arm.

 

6. Power supply cable.

 

7. Rating plate.

 

8. Microswitch.

 

9. Welding time adjustment. (H-3000)

 

10. Control panel. (H-3000S)

 

11. Welding lever

  2.  INTRODUCTION 

MODEL NO.

 

H-3000

H-3000S

Voltage...........................................230v 1ph ......................230v 1ph

Power at 50% ....................................1.3kVA ..........................2.5kVA

Max. welding power...........................6.6kVA ...........................14kVA

No Load Voltage ...................................... 2V ..............................2.5V

Max. short circuit current .....................3.8kA ............................6.3kA

Weight ...............................................10.5kg .......................... 10.5kg

Airborne noise level ...................... <70dB(A) ......................<70dB(A)

MODEL NO.

 

 

Dimensions .........................440 x 100 x 185 ...........440 x 100 x 185

Plug and Socket .................................... 16A ..........................16/32A

Delayed Mains Fuses ............................ 16A ...............................25A

Max spot weld thickness ..................1+1mm .........................2+2mm

Min.rest period between welds ... 20seconds ....................20seconds

Maximum clamping force ...................120kg ........................... 120kg

Projection of arms ............................120mm .........................120mm

  3.  TECHNICAL SPECIFICATION

  4.  ELECTRICAL CONNECTIONS

  

WARNING!

 

Ensure that you read and understand the safety instructions in Section 1.

4.1. 

Connection to mains power supply.

 

Before making any electrical connections check that the voltage of the available power supply is suitable for the spot  

 

 

 

welder model that you have purchased. ( See specification above.)

4.2 

The  H-3000&S

   

 require a 30amp. supply and are suitable for either single phase or three phase connection.

4.3 

The H-3000  requires a 16amp plug and the SR123 requires a 32 amp plug. If connecting to a 30amp supply wire the plug as shown on  

 

page 1. If the unit is to be connected to a 3 phase supply this must be done by a 

qualified electrician

.

4.4 

The mains power supply should be equiped with appropriate fuses or an automatic cut-out switch arrangement.

4.5 

If more than one welding machine is to be installed consult a 

qualified electrician

 regarding a suitable 3 phase supply.

4.6 

Before proceeding to set up and use the welder, ensure that the electrical connections have been made correctly.

fig. 1

A FULL RANGE OF ARMS AND ELECTRODES IS AVAILABLE FOR THE H-3000. REFER TO LAST PAGE OF 

INSTRUCTION OR CONTACT YOUR LOCAL SEALEY DEALER FOR FURTHER INFORMATION.

Original Language Version

Summary of Contents for H-3000

Page 1: ...r supply leads plugs and all electrical connections for wear and damage You must ensure the risk of electric shock is minimised by the installation of appropriate safety devices An RCCB Residual Current Circuit Breaker should be incorporated in the main distribution board We also recommend that an RCD Residual Current Device is used with all electrical products It is particularly important to use ...

Page 2: ...0 x 185 Plug and Socket 16A 16 32A Delayed Mains Fuses 16A 25A Max spot weld thickness 1 1mm 2 2mm Min rest period between welds 20seconds 20seconds Maximum clamping force 120kg 120kg Projection of arms 120mm 120mm 3 TECHNICAL SPECIFICATION 4 ELECTRICAL CONNECTIONS WARNING Ensure that you read and understand the safety instructions in Section 1 4 1 Connection to mains power supply Before making an...

Page 3: ...e locking bolt 5 3 Adjusting the pressure exerted by the electrodes Refer to figs 3 4 The pressure exerted by the electrodes onto the workpiece can be adjusted by altering the spring pressure adjuster underneath and within the handle using the 6mm Hex key provided fig 3 1 To increase the pressure turn the adjuster clockwise To decrease the pressure turn the adjuster anticlockwise On the top face o...

Page 4: ... cut out has operated Allow the welder to cool for at least 5 minutes before attempting to weld again 6 3 Spot welding with H 3000 Electronic Timer Adjust the welding time by using the control mounted on the rear of the unit See fig 6 9 6 4 SPOT WELDING PROCEDURE WARNING Ensure that you read and understand the safety instructions in Section 1 Use welder in a suitable working area Keep area clean a...

Reviews: