background image

2. 

introDuction & sPecification

3.  PreParinG tool for use

Max Cutting Capacity:  . . . . . 1.5mm - steel

free speed: . . . . . . . . . . . . . . . . .3500spm

Air Consumption: . . . . . . . . . . . . . . . . 6cfm

Operating Pressure:   . . . . . . . . . . . . . 90psi

Air Inlet size:  . . . . . . . . . . . . . . . . 1/4”BsP

Weight: . . . . . . . . . . . . . . . . . . . . . . . .1.0kg

Maximum Noise level:. . . . . . . . . . . 114dB

sealey’s Generation or G3 series of air tools represents some of the best design innovations in air tools of 

recent date. The tools feature contoured, soft-grip handle and housing which help reduce the effects of vibration 

and chill – major contributors to circulatory and nerve problems such as white finger. The tools also include 

exhaust systems designed to reduce noise levels by baffling the noise or directing it away from the operator’s 

environment. Most of the tools include integral and adjustable air control valves for precise control of output. The 

air wrenches are, pound for pound, amongst the most powerful machines we have seen in the market and the 

materials and manufacturing techniques used in the production of all the G3 series will ensure long and reliable 

service.

3.1 

air supply

 

Recommended hook-up procedure is shown in fig 1.

3.1.1  Ensure tool air valve (or trigger) is in "off" position before connecting to the air supply.

3.1.2  You will require an air pressure of 90psi, and an air flow according to specification.

3.1.3 

 

WarninG! 

Ensure the air supply is clean and does not exceed 90 psi while operating the tool. Too  

 

high an air pressure and unclean air will shorten the product life due to excessive wear, and may be  

 

dangerous causing damage and/or personal injury. 

3.1.4  Drain the air tank daily. Water in the air line will damage the tool. 

3.1.5  Clean air inlet filter weekly. 

3.1.6  line pressure should be increased to compensate for unusually long air hoses (over 8 metres). The  

 

minimum hose diameter should be 1/4” I.D. and fittings must have the same inside dimensions. 

3.1.7  Keep hose away from heat, oil and sharp edges. Check hose for wear, and make certain that all  

 

connections are secure. 

3.2   couplings. 

 

Vibration may cause failure if a quick change coupling is connected directly to the tool. 

 

To overcome this, connect a leader hose to the tool. A quick change coupling may then be used to  

 

connect the leader hose to the air line recoil hose. see fig 1 & 2. 

risk of Hand arm Vibration injury

Air Nibbler (G3) Model No. GsA28

 when operated in accordance with these instructions and tested in 

accordance with EN 28662-2: 1994 results in the following vibration emission declared in accordance with 

Bs EN12096: 1996. 

Measured vibration emission value:  . . . . . . . . . . .

5.3

m/s²

Uncertainty: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.1

m/s²

these values are suitable for comparison with emission levels of other tools that have been subject to 

the same test.

this tool may cause hand-arm vibration syndrome if its use is inadequately managed.

recommended Measures to reduce risk of hand-arm vibration syndrome:

This tool should not be used by an individual regularly for more than 

218

 minutes in any 8 hour period.

This duration of use should be reduced if the individual is exposed to hand-arm vibration from other sources.

fig 1

fig 2

Original Language Version

GsA28   Issue: 2 - 30/10/09

Reviews: