background image

 NOTE: 

Before any operation, test the seals by pressing the manual button once BEFORE the water valve is opened. Adjust seals if  

 necessary.

5.3.    

MANUAL  OPERATION

5.3.1. 

  

Turn on mains power (fig.3) and air supply. Depress Emergency Safety switch on far side of the unit.

5.3.2. 

  

Pressurise water container and open water inlet valve on air connection fitting (fig.4).

5.3.3. 

  

Check air pressure regulator is set to 2 bar (initial setting) (fig.3).

5.3.4. 

  

With the Manual button lit (fig.2.1), press and hold it in for a short time. This will open the air valve and push air and liquid through the  

 

DPF. Allow air pressure to restore to the set value before repeating operation.

5.4.    

AUTOMATIC  OPERATION

5.4.1.   

Follow steps 5.3.1, 5.3.2, 5.3.3.

5.4.2. 

  

Set timer control (fig.2.3, fig.5) to operate timing and frequency of operation. The top dial controls the valve open time and measured  

 

in seconds while the lower dial sets valve close time and is measured in minutes. When rinsing with water it is recommended to set  

 

open time to 0.1sec and close time to 0.1min and when air drying set open to 0.3sec and close to 0.3min. Users may adjust these  

 

settings accordingly. 

5.4.3. 

  

Press Auto button (fig.2.4) and the machine will function to times set (5.4.2).

 

NOTE: 

During operation it will be necessary to re-pressurize the water container as pressure is released.

 

NOTE: 

Depending on performance, it may be necessary to increase air pressure (suggest maximum of 4 bar fig.3) and to increase  

 

opening and closing times

 

of air inlet solenoid (5.4.2).

6.  MAINTENANCE

6.1. 

  

Regularly check and inspect all hoses and electrical connections. Replace if necessary.

6.2. 

  

Clean down / rinse machine after use with clean fresh water. 

Original Language Version

© Jack Sealey Limited

   fig.4

   fig.5

   fig.2

   fig.3

D

PF1       Issue 2 (5)      23/09/20

Summary of Contents for DPF1

Page 1: ...arth terminal E B Connect the BROWN live wire to the live terminal L C Connect the BLUE neutral wire to the neutral terminal N Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight Sealey recommend that repairs are carried out by a qualified electrician 1 2 GENERAL SAFETY WARNING Ensure Health Safety local authority and general workshop practice regu...

Page 2: ...the face plate and fully engage the DPF into the exposed space NOTE Some PDFs are not designed as straight through e g they may be L or even Z shaped In certain circumstances it is advised to remove the aperture entrance cover fit the discharge adaptor fig 1 8 in place of the cover and attach the clear pipe fig 1 6 between the adaptor and the DPF 5 2 3 Strap DPF firmly to the machine bed using the...

Page 3: ...uency of operation The top dial controls the valve open time and measured in seconds while the lower dial sets valve close time and is measured in minutes When rinsing with water it is recommended to set open time to 0 1sec and close time to 0 1min and when air drying set open to 0 3sec and close to 0 3min Users may adjust these settings accordingly 5 4 3 Press Auto button fig 2 4 and the machine ...

Page 4: ...ds according to local regulations WEEE REGULATIONS Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment WEEE When the product is no longer required it must be disposed of in an environmentally protective way Contact your local solid waste authority for recycling information Note It is our policy to continually impro...