background image

DPF ULTRA CLEANING STATION 

MODEL NO: 

DPF1

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these 

instructions, and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  SAFETY

1.1.    

ELECTRICAL  SAFETY

  

WARNING! 

It is the user’s responsibility to check the following:

 

Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and all  

 

electrical connections for wear and damage. Sealey recommend that an RCD (Residual Current Device) is used with all electrical  

 

products. You may obtain an RCD by contacting your local Sealey stockist. 

 

If the product is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable  

 

 

Appliance Test) tested.

 

ELECTRICAL SAFETY INFORMATION: 

 it is important that the following information is read and understood.

1.1.1.   

Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. 

1.1.2.   

Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.

1.1.3. 

  

IMPORTANT

: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the  

 

correct fuse - see fuse rating in these instructions.

 

8

   DO  NOT

 pull the appliance by the power cable.

 

8

  

DO NOT

 pull the plug from the socket by the cable. 

 

8

   DO  NOT

 use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired or 

             replaced immediately by a qualified electrician.

1.1.4. 

  

This product is fitted with a BS1363/A 13 Amp 3 pin plug. 

      

If the cable or plug is damaged during use, switch the electricity supply and remove from use. 

      

Ensure that repairs are carried out by a qualified electrician.

         

Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.

 

A) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

 

B) Connect the BROWN live wire to the live terminal ‘L’.

 

C) Connect the BLUE neutral wire to the neutral terminal ‘N

’.

      

Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight. 

        

Sealey recommend that repairs are carried out by a qualified electrician.

1.2.    

GENERAL  SAFETY

 

‰

  

WARNING!

 Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using this    

 unit. 

 

9

   Wear appropriate PPE.

 

9

   Familiarise yourself with the applications, limitations and potential hazards of the unit.

 

‰

   WARNING: 

Only use in well ventilated areas. Exhaust gases are poisonous.

 

9

   Operators must receive adequate training before using the unit.

 

9

   Always perform automotive work in a safe environment. 

 

8

  

DO NOT

 operate the unit while under the influence of drugs, alcohol or intoxicating medication, or if tired.

 

8

  

DO NOT

 cover the unit or place heavy loads on top of it.

 

8

  

DO NOT

 operate in wet or damp conditions.

 

9

   Check the condition and operation of all components before each use.

 

9

   Operate the unit on a smooth level surface in order to avoid tipping or spillage.

 

9

   Stand correctly keeping a good footing and balance, ensure that the floor is not slippery and wear non-slip shoes.

 

9

   Keep unauthorised persons away from the work area. Any persons working within the area must wear the same protective items.

 

9

   Keep the unit, hoses and cables in good working order and condition. Take immediate action to repair or replace damaged parts.

2.  INTRODUCTION

P

rovides an off-vehicle, same day workshop cleaning solution. The machine uses a mixture of high pressure air, chemicals and water. This 

cleaning station along with the Sealey recommended chemicals offers a fast and cost effective way to completely clean and protect any DPF. 

Great revenue boost for any workshop. Each treatment will require a DPF Ultra Cleaning Kit (Model No. DPF1KIT) which includes 1 x Ultra 

Clean and 1 x Ultra Protect Solution. The ultra cleaning chemical is a unique solution specially formulated to safely lift impurities from the DPF. 

The protect chemical features the latest nano catalyst technology to keep your DPF cleaner for longer. Also features an automatic service 

function allowing the user to continue with other work.

Replacement fuse 

rating: 13A

D

PF1       Issue 2 (5)    23/09/20

Original Language Version

© Jack Sealey Limited

Refer to 

instructions

 

Wear a face 

shield

 

Wear protective 

gloves

 

Wear safety 

footwear

 Warning 

Electricity

 Keep out of rain  High pressure

air hazard

Summary of Contents for DPF1

Page 1: ...arth terminal E B Connect the BROWN live wire to the live terminal L C Connect the BLUE neutral wire to the neutral terminal N Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight Sealey recommend that repairs are carried out by a qualified electrician 1 2 GENERAL SAFETY WARNING Ensure Health Safety local authority and general workshop practice regu...

Page 2: ...the face plate and fully engage the DPF into the exposed space NOTE Some PDFs are not designed as straight through e g they may be L or even Z shaped In certain circumstances it is advised to remove the aperture entrance cover fit the discharge adaptor fig 1 8 in place of the cover and attach the clear pipe fig 1 6 between the adaptor and the DPF 5 2 3 Strap DPF firmly to the machine bed using the...

Page 3: ...uency of operation The top dial controls the valve open time and measured in seconds while the lower dial sets valve close time and is measured in minutes When rinsing with water it is recommended to set open time to 0 1sec and close time to 0 1min and when air drying set open to 0 3sec and close to 0 3min Users may adjust these settings accordingly 5 4 3 Press Auto button fig 2 4 and the machine ...

Page 4: ...ds according to local regulations WEEE REGULATIONS Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment WEEE When the product is no longer required it must be disposed of in an environmentally protective way Contact your local solid waste authority for recycling information Note It is our policy to continually impro...