background image

4.3. 

  

FUEL DISPENSING

4.3.1.   

Before connecting to a battery, make sure the pump  

 

switch (fig.2.5) is in the “off” (O) position. Connect the  

 

battery clips to the 12V battery, observing correct polarity  

 

(red clamp to + terminal, black clamp to – terminal).

4.3.2.   

Switch the pump switch to the ‘on’ (I) position.

4.3.3.   

Unwind sufficient hose and place the nozzle (fig.2.6) in  

 

the receiving tank and pull the trigger open. 

DO NOT

  

 

leave the nozzle unattended with the trigger latched open.

4.3.4.   

The trigger can be locked in one of three positions by  

 

engaging the latch to hold the trigger open. 

 

8

  

DO NOT

 leave the nozzle unattended with the trigger  

  latched open.

4.3.5.   

Slight pressure on the trigger will release the latch.

4.3.6.   

When the level in the receiving tank reaches the nozzle,  

 

delivery will stop automatically.

4.3.7.   

When delivery is complete, switch off the pump. Ensure  

 

the hose is wound into its housing on the tank and that  

 

the nozzle is secured in its storage place.

 

8

  

DO NOT

 operate the pump continuously for more than  

  30 minutes. The duty cycle of the unit is 30 minutes, after  

  which the motor must be left to cool down for a further  

  30 minutes.

 

8

  

DO NOT

 run the unit for more than 2-3 minutes with the delivery nozzle closed.

5.  MAINTENANCE

 

‰

  

WARNING!

 Always disconnect from the battery before performing any maintenance.

5.1. 

  

The pump contains no user-servicable parts. Repairs should only be undertaken by competent persons.

5.2. 

  

Check the integrity of all the hose connections periodically. If any leakage is evident, strip the joint and wind PTFE tape around the  

 

male thread.

5.3. 

  

Check the electrical connections and cables for wear and damage. Rectify any faults found.

5.4. 

  

Keep clean, especially the dispenser nozzle.

5.5. 

  

Clean with a damp, soapy cloth.

 

8

  

DO NOT

 use abrasive or solvent cleaners.

   fig.2

Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR

 01284 757500 

 01284 703534 

 [email protected] 

 www.sealey.co.uk

ENVIRONMENT PROTECTION

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to 
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely 
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids 
according to local regulations.

WEEE REGULATIONS

Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment 
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid 
waste authority for recycling information.

Note

: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior 