Charging systeM norMal when test with aCCessory loads
the system is showing normal output from the alternator, no problem detected.
Charging systeM high when test with aCCessory loads
the voltage output from the alternator to the battery exceeds the normal limits of a functioning regulator.
check to ensure there are no loose connections and that the earth connection is properly connected.
if there are no connection issues, replace the regulator. since most alternators have the regulator
built in, this will require you to replace the alternator.
5.7.
what is the test Code & how to Use it
5.7.1.
Put the cd or cd/dVd/blue rAY combination drive.
5.7.2.
follow the installation instructions and install the icon named “decode_bt2010_Vxx.x” and the sheet below will pop up.
5.7.3.
input the “test code” into the chart manually or by barcode reader.
5.7.4.
the test result will show in the chart after decoding.
5.7.5.
the test data can be stored in the Pc.
6. settings
6.1.
langUage seleCt
6.1.1.
connect the tester to a battery.
6.1.2.
the tester defaults to the bAtterY test display. Press the directional keys to get to the lAnGuAGe select display.
6.1.3.
Press enter and the display will show the language options. Press the directional keys to select the language you want the tester to
display.
6.1.4.
Press enter and the display returns to bAtterY test.
6.2.
set the date and tiMe
6.2.1.
connect the tester up to a battery.
6.2.2.
the tester defaults to the bAtterY test display. Press the directional keys to get to the current dAte/time display.
6.2.3.
Press enter and the display will show AdJust YeAr. Press the directional keys to change the setting.
6.2.4.
Press enter and the display will show AdJust montH. Press the directional keys to change the setting.
6.2.5.
Press enter and the display will show AdJust dAY. Press the directional keys to change the setting.
6.2.6.
Press enter and the display will show AdJust Hour. Press the directional keys to change the setting.
6.2.7.
Press enter and the display will show AdJust minute. Press the directional keys to change the setting.
6.2.8.
Press enter and the display returns to bAtterY test.
6.3.
adJUst the display brightness
6.3.1.
connect the tester to a battery.
6.3.2.
navigate to the briGHtness display.
6.3.3.
Press the directional keys to adjust the brightness of the display.
Alt. loAd Volts
XX.XXV HiGH
Alt. loAd Volts
XX.XXV normAl
Original Language Version
© Jack sealey limited
bt2015 | issue:1 17/10/17