INSTRUCTIONS FOR:

ON-GUN AIR PRESSURE

REGULATOR / GAUGE DIGITAL

MODEL NO: 

ARD01

Refer to Instruction 

Manual

1. SAFETY

 

WARNING!

 

Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using 

 

this equipment.

 

WARNING!

 

Disconnect the equipment from the air supply before changing accessories,servicing or performing any    

 maintenance.

 

Keep the equipment clean and maintain it in good condition (use an authorised service agent).

 

Replace or repair damaged parts. 

Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the 

 warranty.

 

WARNING!

 Ensure that the correct air pressure is maintained and not exceeded. 

 

Keep air hoses away from heat, oil and sharp edges. Check hoses for wear before each use and ensure that all connections 

 

are secure.

 

DO NOT

 direct air from the air hose at yourself, others or animals.

 

DO NOT

 operate air tools when tired or under the influence of drugs, alcohol or intoxicating medication.

 

Drain the compressor air tank and the filter bowl daily. Water in the air line will damage your equipment.

 

When work is complete ensure that the air supply is turned off.

2. INTRODUCTION

On-gun pressure regulator/gauge with digital LCD display. On/off button with adjustable auto-off function for extended battery life. 

Small and compact with composite body. Pressure can be displayed in psi, bar or MPa. Just one of a comprehensive range of 

quality spray gun accessories.

3. SPECIFICATION

4. SETTINGS

 

Model No:

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

ARD01

 

Maximum Pressure: . . . . . . . . . . . . . . . . . . . . . . . . . . . 150psi/10bar/1MPa

 

Maximum Flow:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18cfm at 100psi

4.1

  Press the on/off button once to switch the gauge on or off.

4.2. 

Additionally, the on/off button may be used to alter the three function settings.

4.3.  Resetting the gauge to zero:

 

4.3.1. 

Ensure that the gauge is not under pressure.

4.3.2. 

With the gauge switched on, hold the on button for about 3 seconds, until the display shows ‘---’ then release the  

   button.

4.3.3. 

The display will cycle between 0,1 and 2. 

4.3.4. 

Select 0 and the display will show 00-.

4.3.5. 

Press the button again and the display will show 000.

4.3.6. 

Press the button again within 3 seconds and the gauge will reset to zero.

4.3.7. 

‘End’ will display for 2 seconds and the unit will switch off automatically.

4.4  Automatic Shut Off mode.

4.4.1. 

The default automatic shut off time is 60 seconds.

4.4.2. 

To change the automatic shut off time, select mode 1 as per instructions as at 4.3.2 and 4.3.3.

4.4.3.

 

The display will cycle between 30, 60 120 and 180 seconds.

4.4.4. 

Press the button to select the required automatic shut off time.

4.4.5. 

The selected time will flash 3 times and ‘end’ will display before the unit switches off.

© Jack Sealey Limited

    Original Language Version 

  ARD01  Issue: 1 - 02/06/16