Problem

cause

solution

erratic action

Air in system

Viscosity of oil too high

ram sticking or binding

With jack sitting on its base and ram 

retracted, bleed air from unit, see 

section 4.2

change to lower viscosity oil

look for dirt or gummy deposits, leaks, 

misalignment, worn parts or defective 

packing.

ram does not advance

release valve is open

low/no oil in reservoir

Air locked in system

load is above capacity of system

close release valve

fill with oil and bleed system

Bleed the system

use correct equipment

ram extends only partially

low oil level in reservoir

Piston rod is binding.

fill with oil to oil line and bleed system.

look for dirt, gummy deposits, leaks, 

misalignment, worn parts or defective 

packing.

ram advances slowly

Pump not working correctly

leaking seals

take jack to authorised service centre 

for pump repair.

repair with seal kit

ram advances but does not hold 

pressure

Pump check valve not working

ram seals are leaking

take jack to authorised service centre 

for seal replacement

repair with seal kit

Jack leaks oil

Worn or damaged seals

repair with seal kit

ram will not retract or retracts slowly

release valve is closed

reservoir is too full

ram damaged internally

open release valve

drain oil to correct level

take jack to authorised service centre 

for repair

 

environmental Protection

recycle unwanted materials instead of disposing of them as waste. all tools, accessories and packaging should be 

sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment.

When the product becomes completely unserviceable and requires disposal, drain off any fluids (if applicable)

into approved containers and dispose of the product and the fluids according to local regulations.