background image

SeaI/O OEM User Manual   

 

 

 

 

 

 

 

 

 

 

www.sealevel.com 

PO Box 830 – Liberty, SC  29657 

864.843.4343 

 

https://www.impulse-embedded.co.uk/products/420u_oem--Digital-Input-Relay-Output-OEM-board.htm

https://www.impulse-embedded.co.uk/products/420u_oem--Digital-Input-Relay-Output-OEM-board.htm

Summary of Contents for SeaI/O-410E

Page 1: ...vel com PO Box 830 Liberty SC 29657 864 843 4343 https www impulse embedded co uk products 420u_oem Digital Input Relay Output OEM board htm https www impulse embedded co uk products 420u_oem Digital...

Page 2: ...MODULE POWER CONNECTION 18 SEAI O EXPANSION POWER CONNECTION 18 SEAMAX APPLICATION SUITE 20 SEAMAX OVERVIEW 20 COMMUNICATING VIA MODBUS 21 SEAMAX SOFTWARE INSTALLATION 22 MAXSSD CONFIGURATION DIAGNOS...

Page 3: ...ser Manual APPENDIX A HOW TO GET ASSISTANCE 57 APPENDIX B CAD DRAWING 58 APPENDIX C COMPLIANCE NOTICES 59 FEDERAL COMMUNICATIONS COMMISSION STATEMENT 59 WARRANTY 60 https www impulse embedded co uk pr...

Page 4: ...IDC SeaI O 470U 8 Inputs 8 Outputs 2 D A 16 A D SeaI O 520U 8 Optically Isolated Inputs 8 High Current Form C Outputs RS 485 SeaI O 410M 16 Optically Isolated Inputs 16 Reed Relay Outputs SeaI O 420M...

Page 5: ...ions and environments including Process Control Data Acquisition Broadcast Automation Security Facility Management Features Choice of Connectivity o Wireless 802 11b g coming soon o Ethernet o USB o R...

Page 6: ...able for direct connection to a computer s Ethernet port DO NOT connect the yellow crossover cable to the RJ45 RS 485 pass through connectors on the left side of the SeaI O module U Series USB Item CA...

Page 7: ...ocal installations should use the 5 CAT5 RS 485 pass through cable Item CA239 shipped with each N series module to connect Remote expansion modules should use RS 485 twisted pair wiring from the Base...

Page 8: ...lso included on the front of all SeaI O OEM modules to indicate the following information Communication Yellow Blinks when data is transmitted Fault Red Lights when there is a problem with the device...

Page 9: ...ach group shares a common for easy wiring via removable 3 5mm terminal blocks Ethernet version shown Inputs Type 16 non polarized optically isolated inputs Voltage Range 5 30VDC Isolation 300V Input R...

Page 10: ...vable terminal blocks USB version shown Inputs Type 16 non polarized optically isolated inputs Voltage Range 5 30VDC Isolation 300V Input Resistance 6 2K Ohms in series Response Time 4 microseconds Ou...

Page 11: ...nection to real world signals is made via 3 5mm convenient removable screw terminal connectors RS 232 version shown Inputs Type 32 non polarized optically isolated inputs Voltage Range 5 30VDC Isolati...

Page 12: ...ompatible with 14 22 AWG wiring allow reliable connection to real world I O RS 485 version shown Outputs Type 32 SPST Form A Reed relays Power 10VA max Contact Voltage 60VDC max Contact Current 500mA...

Page 13: ...normally open and normally closed contact connections via 3 5mm field removable terminal blocks Ethernet version shown Outputs Type 16 SPDT Form C relays Power DC 30W AC 60 VA Contact Voltage 60VDC ma...

Page 14: ...connectors Order part number 462x KT and receive two CA237 cables with each unit RS 485 version shown Power Requirements Max Output Power 5VDC 1A 5W Inputs Logic High Min 2VDC Logic Low Max 0 8VDC Out...

Page 15: ...SRs for a total of 16 channels Features a 50 pin header connector for easy interface via 50 conductor ribbon cables Quad Solid State Relay Modules AC Input Part Number IA5Q Provides 4 channels of disc...

Page 16: ...rol systems and other industrial automation systems A metal strain relief bracket is included to secure the cables after installation RS 485 version shown Power Requirements Max Output Power 5VDC 1A 5...

Page 17: ...O 463 s 50 pin header connectors to your I O 6 Snap track and DIN rail clips are included for DIN rail mounting IDC 50 to IDC 50 Pin 40 Ribbon Cable Item CA167 Interfaces each of the SeaI O 463 s 50...

Page 18: ...easy interface via 50 conductor ribbon cables Quad Solid State Relay Modules AC Input Item IA5Q Provides 4 channels of discrete I O interface to monitor AC inputs up to 140V 10mA DC Input Item IB5Q P...

Page 19: ...applications the SeaI O 470 includes removable screw terminals which simplify field wiring connections RS 232 version shown Optically Isolated Inputs Input Range 5 30VDC Open Collector Outputs Output...

Page 20: ...USB version shown Inputs Type 8 non polarized optically isolated inputs Voltage Range 5 30VDC Isolation 300V Input Resistance 6 2K Ohms in series Response Time 4 microseconds Outputs Type 8 SPDT High...

Page 21: ...eparate power is required at each expansion unit SeaI O Max Power Requirements E Series U Series M Series S Series N Series SeaI O 410 2 9W 1 7W 1 4W 1 6W 1 4W SeaI O 420 3 5W 2 3W 2 0W 2 2W 2 0W SeaI...

Page 22: ...nsion units attention should be given to ensure the input power to the Base module is adequate Example Power W Base Unit SeaI O 430U 0 7 Expansion 1 SeaI O 410N 1 4 Expansion 2 SeaI O 440N 2 5 4 6W Po...

Page 23: ...omatically installed with the SeaMAX Suite and can be found in Windows by clicking Start All Programs Sealevel SeaMAX Documentation Additional SeaMAX documentation is available online that completely...

Page 24: ...rted An overview of the Modbus specification for both RTU and TCP connections is covered in detail in the interactive documentation located on the Sealevel website at http www sealevel com software Se...

Page 25: ...tall the proper components Follow the information presented on the installation screens that follow 7 A screen may appear with the declaration The publisher cannot be determined due to the problems be...

Page 26: ...wn box allows the selection of a serial COM port from COM1 to COM256 Ethernet for Ethernet SeaI O modules or SeaDAC Lite USB USB connected SeaI O and SeaDAC modules are installed as virtual COM ports...

Page 27: ...bsequent pages To communicate with a SeaI O Ethernet module select ETHERNET from the COM Port dropdown box When Ethernet is selected MaxSSD searches for any SeaI O Ethernet modules on the network and...

Page 28: ...246 are available However each daisy chained SeaI O module must have a unique slave ID address no duplicates are allowed SeaDAC modules are only available on slave ID 247 and this number cannot be ch...

Page 29: ...t Modbus TCP interface The Set Settings and Change Slave ID buttons will also be enabled for this module After a successful Get operation additional tabs may be displayed in MaxSSD depending on the fo...

Page 30: ...he two modules set to 9600 bps will receive the broadcast set data rate and parity message NOTE Important note regarding SeaI O Ethernet E series modules The broadcast feature sets the Ethernet SeaI O...

Page 31: ...ould show two banks of inputs and one bank of outputs When banks of inputs are displayed the status LEDs update on each of the banks automatically This allows you to actively monitor external signals...

Page 32: ...an be set using the buttons below each output LED As each coil is set the SeaDAC Lite module is read The corresponding status LED in the Digital IO window indicates the state of the coil In the exampl...

Page 33: ...n the device will now function as inputs For ease of configuration an All Banks of IO option is available to configure all of the I O at one time Inputs have no preset mode therefore the preset option...

Page 34: ...the various configuration options 10x Hardware Gain Enabled checkbox Indicates whether or not the onboard hardware gain jumper is currently set This option is not user configurable it only reflects th...

Page 35: ...figuration section of this manual for instructions on opening the enclosure and accessing the correct jumpers To adjust a particular channel s output voltage drag the slider until the desired voltage...

Page 36: ...eaDAC 8227 module s A D channels the application program must convert the returned values to engineering units voltage Likewise the application program must output the correct value to the I O module...

Page 37: ...two or more SeaI O modules together Crossover cables should only be used to connect an Ethernet SeaI O module to a host without going through an Ethernet hub or switch 7 On SeaI O modules verify that...

Page 38: ...so possible that the SeaI O module may not be discovered if the PC and module are on separate subnets This may occur if the module s IP address is configured outside the range of the PC s subnet It ca...

Page 39: ...ween 1 and 15 F the SeaI O module will always respond to commands issued at that slave ID This is useful when there are fewer than 16 SeaI O modules in a chain and the slave ID is not required to chan...

Page 40: ...wn resistors ensure that the input ports are at a known state when not being driven by the RS 485 line In most cases all three of the dipswitches on each SeaI O module should be in the down position e...

Page 41: ...IP address or COM port to communicate with the base module Ensure a successful Get operation refer to the MaxSSD section on the following pages for more information Set the slave ID of the base modul...

Page 42: ...damage to Ethernet devices WILL result Ensure a successful Get operation refer to the MaxSSD section on the following pages for more information Set the slave ID of the expansion module using the rota...

Page 43: ...s LEDs will remain on If no DHCP server is available the Ethernet SeaI O module will default to a random IP address in the range 169 254 x x To discover the Ethernet SeaI O module s IP address start t...

Page 44: ...ss section on the previous pages This guarantees that any expansion modules connected next will not conflict with the base module Perform another Get operation to verify that you can communicate with...

Page 45: ...thernet patch cable blue and an Ethernet crossover cable yellow Enter the MAC address found on the label on the SeaI O board A MAC address is made up of six pairs of hex digits separated by dashes i e...

Page 46: ...O 470 Jumper Locations This detail image of the right side of the SeaI O 470 circuit board shows the locations of the user configurable jumpers and dipswitches Refer to the following pages for instruc...

Page 47: ...and setting the SeaI O 470 A D input channel for 0 10V range You can also set the A D input channel for 0 5V to sense voltages smaller than 0 5V When the jumper is enabled the 10X Hardware Gain checkb...

Page 48: ...ion modules that are less than ten feet from a base unit a standard RJ45 CAT5 patch cable may be used For SeaI O modules greater than ten feet apart use twisted pair cable connecting the data lines to...

Page 49: ...the inputs each group of four Reed relays also shares a single common and connects via a five position removable screw terminal Form C Relay outputs are arranged such that each group of two relays sh...

Page 50: ...Bits 1 48 Bits A1 B1 C1 A2 B2 C2 D0 75 38 18 10 30 2 D1 76 37 17 9 29 1 D2 77 36 16 8 28 22 D3 78 35 15 7 27 21 D4 59 34 14 6 26 40 D5 39 33 13 5 25 60 D6 20 32 12 4 24 61 D7 19 31 11 3 23 62 Bits 49...

Page 51: ...7 that terminates the DB 78 to two industry standard 50 pin header connectors Two cables and a SeaI O unit can be ordered together as a kit using Item 462x KT The pinout for the two 50 pin headers is...

Page 52: ...ware command as an input or an output The SeaI O 463 s four header connectors are labeled P2 P3 P4 and P5 The connector designators are silk screened onto the PCB for easy identification Each of the f...

Page 53: ...iguring the current loop dipswitches The SeaI O 470 can be configured for up to sixteen 12 bit single ended A D inputs Each input is referenced to a common ground The user selectable voltage ranges ar...

Page 54: ...Connections The SeaI O 470 provides two 12 bit D A output channels configured for 0 10V 0 5V mode requires different jumper settings on the board Refer to the Hardware Configuration section of this m...

Page 55: ...aI O 470 modules provide eight open collector digital outputs The outputs do not source any current and must be connected to an external power source max 30VDC The outputs act as a switch and the circ...

Page 56: ...removable screw terminal Input voltage range is 5 30VDC Like the inputs each group of two Form C relays also shares a single common The NC and NO contacts of each relay along with the commons are brou...

Page 57: ...llows SeaI O S series modules to be easily connected to a standard DB9 RS 232 serial port For other interfacing options the RJ45 serial pin out is shown below NOTE For SeaI O S series modules pin 4 of...

Page 58: ...t Power Supply connects via screw terminals no wire included International Options TR108 AU 100 250VAC to 24VDC 36W 1 5A Desktop Power Supply with 1 3mm Plug includes CA187 AS 3112 6 Australian Power...

Page 59: ...be used to connect SeaI O Ethernet modules to a hub or can be used as an RS 485 interconnect cable to cascade SeaI O modules via the RS 485 In Out ports CA179 USB 6 A to B Cable included with 4xxU Se...

Page 60: ...ccessed from our home page Manuals and software can also be downloaded from the product page for your device Sealevel Systems provides an FAQ section on our website Please refer to this to answer many...

Page 61: ...Appendix B CAD Drawing Sealevel Systems Inc 58 SeaI O OEM User Manual https www impulse embedded co uk products 420u_oem Digital Input Relay Output OEM board htm...

Page 62: ...ve 89 336 EEC and of the low voltage directive 73 23 EEC issued by the European Commission To obey these directives the following European standards must be met EN55022 Class A Limits and methods of m...

Page 63: ...ccepted Authorization is obtained by calling Sealevel Systems and requesting a Return Merchandise Authorization RMA number The Customer agrees to insure the Product or assume the risk of loss or damag...

Reviews: