17
© Sealevel Systems, Inc. 7103 Manual | SL9161 7/2021
Appendix C
–
Electrical Interface, Continued
RS-485
RS-485 is backwardly compatible with RS-422; however, it is optimized for party-line or multi-drop
applications. The output of the RS-422/485 driver is capable of being
Active
(enabled) or
Tri-State
(disabled). This capability allows multiple ports to be connected in a multi-drop bus and selectively polled.
RS-485 allows cable lengths up to 4000 feet and data rates up to 10 Megabits per second. The signal levels
for RS-485 are the same as those defined by RS-422. RS-485 has electrical characteristics that allow for 32
drivers and 32 receivers to be connected to one line. This interface is ideal for multi-drop or network
environments. RS-485 tri-state driver (not dual-state) will allow the electrical presence of the driver to be
removed from the line. Only one driver may be active at a time and the other driver(s) must be tri-stated.
RS-485 can be cabled in two ways, two wire and four wire mode. Two wire mode does not allow for full
duplex communication and requires that data be transferred in only one direction at a time. For half-duplex
operation, the two transmit pins should be connected to the two receive pins (Tx+ to Rx+ and Tx- to Rx-).
Four wire mode allows full duplex data transfers. RS-485 does not define a connector pin-out or a set of
modem control signals. RS-485 does not define a physical connector.