SeaLevel COMM Plus 4.PCI User Manual Download Page 11

 

11 

© Sealevel Systems, Inc.  7103 Manual   |   SL9161  7/2021 

Hardware Installation 

The

 

ULTRA COMM+I.PCI can be installed in any of the PCI expansion slots and contains several jumper 

straps for each port that must be set for proper operation. 

1.

 

Turn off PC power. Disconnect the power cord. 

2.

 

Remove the PC case cover. 

3.

 

Locate an available PCI slot and remove the blank metal slot cover. 

4.

 

Gently insert the ULTRA COMM+I.PCI into the slot. Make sure that the adapter is seated properly. 

5.

 

Replace the screw. 

6.

 

Replace the cover. 

7.

 

Connect the power cord. 

Installation is complete. 

 

 

 

 

 

 

 

 

 

Summary of Contents for COMM Plus 4.PCI

Page 1: ...1 Sealevel Systems Inc 7103 Manual SL9161 7 2021 ULTRA COMM I PCI User Manual 7103...

Page 2: ...LATION 10 HARDWARE INSTALLATION 11 TECHNICAL DESCRIPTION 12 SPECIFICATIONS 13 APPENDIX A TROUBLESHOOTING 14 APPENDIX B HOW TO GET ASSISTANCE 15 APPENDIX C ELECTRICAL INTERFACE 16 APPENDIX D GROUND LOO...

Page 3: ...tial Select RS 485 and capture data from multiple peripherals in a RS 485 multidrop network Up to 31 RS 485 devices can be connected to each port to automate your data collection You can even mix the...

Page 4: ...Conventions Warning The highest level of importance used to stress a condition where damage could result to the product or the user could suffer serious injury Important The middle level of importanc...

Page 5: ...al SL9161 7 2021 Factory Default Settings The ULTRA COMM I PCI factory default settings are as follows Port Electrical Specification Port 1 RS 422 To install the ULTRA COMM I PCI using factory default...

Page 6: ...our adapter Figure 1 RS 232 Figure 2 RS 422 Figure 3 RS 485 4 Wire with Echo Figure 4 RS 485 2 wire with Echo Figure 5 RS 485 2 wire without Echo 1 2 3 4 5 6 7 ON OFF 8 9 10 1 2 3 T P P L L E RS 232 1...

Page 7: ...work environments RS 485 requires a tri state driver that will allow the electrical presence of the driver to be removed from the line The driver is in a tri state or high impedance condition when thi...

Page 8: ...to the On position see Figure 5 Figure 6 RS 485 Enable modes Clock Modes The ULTRA COMM I PCI employs a unique clocking option that allows the end user to select from divide by 4 and divide by 1 clock...

Page 9: ...1200 bps 300 bps 2400 bps 600 bps 4800 bps 1200 bps 9600 bps 2400 bps 19 2K bps 4800 bps 57 6 K bps 14 4K bps 115 2 K bps 28 8K bps 230 4K bps 57 6K bps 460 8K bps 115 2K bps If your communications pa...

Page 10: ...ver being loaded It will not cause any harm to your system 4 During setup the user may specify installation directories and other preferred configurations This program also adds entries to the system...

Page 11: ...or each port that must be set for proper operation 1 Turn off PC power Disconnect the power cord 2 Remove the PC case cover 3 Locate an available PCI slot and remove the blank metal slot cover 4 Gentl...

Page 12: ...mat interrupt control and industry leading 128 byte FIFOs Connector Pin Assignments RS 232 Signals DB 25 Male Signal Name Pin Mode GND Ground 7 RD Receive Data 3 Input CTS Clear To Send 5 Input TD Tra...

Page 13: ...ealevel Systems Printed Circuit boards are built to UL 94V0 rating and are 100 electrically tested These printed circuit boards are solder mask over bare copper or solder mask over tin nickel Power Co...

Page 14: ...an on board header block Refer to the section on Card Setup for help in choosing an I O address and IRQ 4 Make sure the Sealevel Systems adapter is securely installed in a motherboard slot 5 When run...

Page 15: ...an FAQ section on its web site Please refer to this to answer many common questions This section can be found at http www sealevel com faq asp 4 Sealevel Systems maintains a web page on the Internet...

Page 16: ...ates The RS 232 and the EIA TIA 574 specification define two types of interface circuits Data Terminal Equipment DTE and Data Circuit Terminating Equipment DCE The ULTRA COMM I PCI is a DTE device RS...

Page 17: ...llow for 32 drivers and 32 receivers to be connected to one line This interface is ideal for multi drop or network environments RS 485 tri state driver not dual state will allow the electrical presenc...

Page 18: ...can cause equipment malfunction or even destruction Cabling Recommendations When connecting the ULTRA COMM I PCI in a RS 485 network care should be taken that both ends of the network are not isolated...

Page 19: ...e character is defined by the transmission of a pre defined number of stop bits usually 1 1 5 or 2 An extra bit used for error detection is often appended before the stop bits Figure 9 Asynchronous Co...

Page 20: ...20 Sealevel Systems Inc 7103 Manual SL9161 7 2021 Appendix F Silk Screen 3 5 4 9...

Page 21: ...to correct the interference at the user s expense EMC Directive Statement Products bearing the CE Label fulfill the requirements of the EMC directive 89 336 EEC and of the low voltage directive 73 23...

Page 22: ...ty Warranty service may be obtained by delivering the Product to Sealevel and providing proof of purchase Customer agrees to ensure the Product or assume the risk of loss or damage in transit to prepa...

Reviews: