Appendix B – Handling Instructions  

ESD Warnings 
Electrostatic Discharges (ESD) 

A sudden electrostatic discharge can destroy sensitive components. Proper packaging and grounding 
rules must therefore be observed. Always take the following precautions: 
 

1.

 

Transport boards and cards in electrostatically secure containers or bags.  

2.

 

Keep electrostatically sensitive components in their containers, until they arrive at an 
electrostatically protected workplace.  

3.

 

Only touch electrostatically sensitive components when you are properly grounded.  

4.

 

Store electrostatically sensitive components in protective packaging or on anti-static mats.  

Grounding Methods  

The following measures help to avoid electrostatic damages to the device:  
 

5.

 

Cover workstations with approved antistatic material. Always wear a wrist strap connected to a 
properly grounded workplace. 

6.

 

Use antistatic mats, heel straps, and/or air ionizers for more protection.  

7.

 

Always handle electrostatically sensitive components by their edge or by their casing.  

8.

 

Avoid contact with pins, leads, or circuitry.  

9.

 

Turn off power and input signals before inserting and removing connectors or connecting test 
equipment.  

10.

 

Keep work area free of non-conductive materials such as ordinary plastic assembly aids and 
Styrofoam.  

11.

 

Use field service tools such as cutters, screwdrivers, and vacuum cleaners that are conductive

.  

 

 

 

Summary of Contents for 8012e

Page 1: ...1 Sealevel Systems Inc 8012e Manual SL9225 12 2022 DIO 16 LPCIe User Manual 8012e...

Page 2: ...8 PHYSICAL INSTALLATION 9 PROGRAMMING THE DIO 16 LPCIE 10 TECHNICAL SPECIFICATIONS 17 APPENDIX A TROUBLESHOOTING 19 SEAIO DEVICE DRIVER CONFIGURATION 25 APPENDIX B HANDLING INSTRUCTIONS 28 APPENDIX C...

Page 3: ...tance used to stress a condition where damage could result to the product or the user could suffer serious injury Important The middle level of importance used to highlight information that might not...

Page 4: ...cable Extend a DB44 cable or locate a piece of hardware where it is needed with this six foot 72 cable The connectors are pinned one to one so the cable is compatible with any device or cable with DB4...

Page 5: ...efore it can be used with any DB37 board regardless of the board s port gender The TB02 KT ships with a RoHS compliant TB02 terminal block a 6 piece of slotted Snap Track and two DIN rail mounting cli...

Page 6: ...when energized The board meets the requirements a low profile PCI Express add in card as defined by the PCI SIG in the PCI Express Card Electromechanical Specification Revision 1 1 The DIO 16 LPCIe is...

Page 7: ...DIO 32 PCI 8004H 16 Reed Relay Outputs 16 Opto isolated Inputs 10 30V ISO 16 PCI 8006 16 Opto isolated Inputs ISO 16 PCI 8006H 16 Opto isolated Inputs 10 30V REL 32 PCI 8007 32 Reed Relay Outputs PLC...

Page 8: ...tall the proper components Follow the information presented on the screens that follow 5 A screen may appear with text similar to The publisher cannot be determined due to the problems below Authentic...

Page 9: ...y installed To prevent damage from improper handling please reference Appendix B ESD Handling Instructions 1 Turn off PC power Disconnect the power cord 2 Remove the PC case cover 3 Locate an availabl...

Page 10: ...al Basic using the ActiveX control included with SeaI O is advised Samples and Utilities A variety of sample programs and utilities both executable and source code are included with SeaI O Further doc...

Page 11: ...PC without the risk of damage due to ground loops or ground faults Each sensor input pair has a current limiting resistor that is used to limit the input current to the opto isolator The opto isolato...

Page 12: ...the DB 44 through the optocoupler out pin 41 and back to the power source If the current flow is between 2 and 20 mA this input will be read as logic 0 All the input associated with all open switches...

Page 13: ...4 32 5 K6 15 33 6 K7 16 34 7 K8 17 35 The above diagram is representative of how lights or other devices can be controlled by the relay outputs When relay 2 on the card is closed it will allow current...

Page 14: ...Signal Pin s Ground 22 23 24 5 Volts 39 12 Volts 1 DB 37 Male Pin Assignment Via optional DB 44 Male to DB 37 Male 6 cable Part Number CA206 Bit Port A Pins Port C Pins 0 2 20 10 28 1 3 21 11 29 2 4 2...

Page 15: ...ler out pin 21 and back to the power source If the current flow is between 2 and 20 milliamps this input will be read as logic 0 All the input associated with all open switches will be read as logic 1...

Page 16: ...to flow from the power source into pin 12 of the DB 37 through the optocoupler out pin 30 and back to the power source thereby turning the light labeled 2 on The above diagram shows the common path to...

Page 17: ...RMS Reed Relay Output Ports Contact Max Power 10W Switching Voltage Max DC Peak AC Resistive 60V Switching Current Max DC Peak AC Resistive 0 5A Life Expectancy Typical Signal Level 1V 10mA 100 milli...

Page 18: ...clude Output Power pins 5V 12V Environmental Specifications Specification Operating Storage Temperature Range 0 C 70 C 35 C 100 C Humidity Range 10 to 90 R H Non Condensing 10 to 90 R H Non Condensing...

Page 19: ...t verify that your Sealevel Software is properly installed This places the required installation files in the correct locations In Windows it will be located here Start All Programs SeaIO Uninstall Re...

Page 20: ...y assigned addressing and IRQs by the system BIOS based on availability Ensure that available IRQs are set to PCI PNP this represents Plug and Play 2 If hardware installation issues persist remove oth...

Page 21: ...ree utilities were designed to verify the functionality of your Sealevel digital I O adapters To access these utilities navigate to Start All Programs SeaIO VB Test This utility allows the setting and...

Page 22: ...SeaIOTST This utility is a Win32 console application designed for testing all calls to the driver This utility is very useful for verifying proper SeaIO driver configuration and hardware adapter sett...

Page 23: ...23 Sealevel Systems Inc 8012e Manual SL9225 12 2022 SeaI O Classic Hardware This is an example of a properly enumerated SeaI O digital I O adapter in Windows Device Manager...

Page 24: ...evice category and choose Properties This will show the Properties dialog box as seen below This verifies that the SeaI O digital I O adapter 8004 is correctly enumerated To properly configure your di...

Page 25: ...river call The default value on installation is 250 000 microseconds 250 milliseconds Setting the sampling rate below 10 000 microseconds is not recommend as this can heavily tax the host processor Wh...

Page 26: ...te SeaIO_ReadBit SeaIO_WriteBit SeaIO_WriteAllOutputs and SeaIO_ReadAllInputs These functions should be used exclusively by new applications Positive Logic PIO cards Inputs If the input threshold volt...

Page 27: ...ten to the port the output is 0v DIO cards Inputs If the input threshold voltage has not been met the API returns a 1 If the input threshold voltage has been met the API returns a 0 Outputs If a 0 is...

Page 28: ...ically sensitive components in protective packaging or on anti static mats Grounding Methods The following measures help to avoid electrostatic damages to the device 5 Cover workstations with approved...

Page 29: ...29 Sealevel Systems Inc 8012e Manual SL9225 12 2022 Appendix C Example Circuits Input Circuit Output Circuit...

Page 30: ...30 Sealevel Systems Inc 8012e Manual SL9225 12 2022 Appendix D 8012e PCB Drawing...

Page 31: ...r to this to answer many common questions This section can be found at http www sealevel com faq htm 4 Sealevel Systems maintains a Home page on the Internet Our home page address is www sealevel com...

Page 32: ...aring the CE Label fulfill the requirements of the EMC directive 89 336 EEC and of the low voltage directive 73 23 EEC issued by the European Commission To obey these directives the following European...

Page 33: ...e radio interference in which case the user may be required to take adequate measures to prevent or correct the interference Always use cabling provided with this product if possible If no cable is pr...

Page 34: ...nty Warranty service may be obtained by delivering the Product to Sealevel and providing proof of purchase Customer agrees to ensure the Product or assume the risk of loss or damage in transit to prep...

Reviews: