Negative Logic
PIO cards
Inputs: If the threshold voltage has not been met the API
returns a 1.
If the input threshold voltage has been met the API
returns a 0.
Outputs: If a 0 is written to the port the output is 3-5v.
If a 1 is written to the port the output is 0v.
DIO cards
Inputs:
If the input threshold voltage has not been met the
API returns a 1.
If the input threshold voltage has been met the API
returns a 0.
Outputs:
If a 0 is written to the port the relay is energized.
If a 1 is written to the port the relay is de-
energized.
Additional information for Positive and Negative logic choices can be located in the SeaIO Software