© Sealevel Systems, Inc. 3603 Manual | SL9111 7/2021
Command Line Options
To display the available command line options, Type “
SeaPC
/?” at the DOS command prompt. The
following should be displayed.
C:>
SeaPC
/?
Sealevel Systems, Inc.
SeaPC
PC Card I/O Enabler Version 1.00
Sealevel Systems Inc. (C) 1994. All rights reserved.
Syntax:
SeaPC
[/F:file] [/U] [/I] [/V] [/?]
/F:[file] Where file is the configuration file
/U
Unconditional installation
/I
Display info on resident copies of
SeaPC
without installing the enabler
/V
Show verbose installation information
/?
Display command line options, inhibit driver from loading
The /F: option is the only required command line parameter. If the setup file is not located in the
default directory, the drive and path must be specified. The following section details the syntax of
the setup file.
Setup File
An example setup file named
SeaPC
.INI is available upon your request. Please contact Sealevel’s Technical
Support for additional information. This file may be edited with the DOS EDIT utility. The following is the
syntax for a PC Card configuration:
[card]
BaseIO =
Base I/O address
IRQ =
Interrupt Request Signal
Type =
Device Type
Interface =
Electrical Interface Utilized
All items in
italics
need to be provided by the user. The following is a description of each entry in
the setup file: