background image

1.9"(4.8 cm)

FP FAUCET
PART NUMBER
Chrome 707203

.725" (1.9 cm)

7.4"

(18.8 cm)

6.0"

(15.3 cm)

2.1"

(5.3 cm)

4.1"

 (10.4 cm)

Cut out faucet base pattern and use for rough position.  Tape pattern
in place. Then, for final positioning, place faucet on pattern on top
of sink and check for correct orientation of faucet body, spout and
handle. This final positioning is needed before making your
installation hole.

It is important to note control handle position and “throw” to
insure adequate clearance.

Also note the “swing feature” of the faucet’s spout that allows many
different mounting options.

Make sure of all clearances above 

and below

 sink before drilling

mounting hole.

Mounting Hole Pattern for

FP Faucet

PATTERN OF BASE OF FP FAUCET SHOWING HOLE
LOCATION (ACTUAL SIZE)

Faucet Care Instructions

All General Ecology, Inc. purifiers feature lead free ports and faucets.
Faucets are manufactured with the finest components available.
However, they require proper care to keep them looking their best.

If properly cared for, these finishes can provide a lifetime of elegance.
Chrome finishes can be damaged by abrasive cleaners, in spite of their
hardness. To clean faucet surfaces properly, use a small amount of a
non-abrasive liquid detergent and a soft wet cloth. Gently rub the soiled
surface until the dirt is removed. Then rinse clean and wipe with a dry
soft cloth to remove water drops and to prevent spotting. Do not use
any abrasive or pumice type cleansers to clean the surfaces of these
faucets, or you may permanently scratch or otherwise damage the faucet
coating. Hard water may leave mineral deposits or “water spots”. If
not cleaned regularly, these deposits may resist cleaning with simple
liquid detergents. These can usually be removed using a small amount
of vinegar applied directly and rubbing with a soft cloth. Heavy deposits
may require repeated applications.

© 2004 General Ecology, Inc. • ®, ™ Trademarks of General Ecology, Inc. • All health claims not in accordance with local or state laws are hereby withdrawn. • 200712 revB 9/07

SEAGULL

®

IV X-1F Positioning and

Dimension Information

1.9" (4.8 cm)

Base Diameter

.75" (1.9 cm.) Hole Diameter

6

Other Great Products Available

from General Ecology, Inc.

(610) 363-7900 • fax (610) 363-0412 • www.generalecology.com

2.9"

(7.3 cm)

5"

(12.7 cm)

4.1"

(10.5 cm)

5.4"

(13.7 cm)

2.5"

(6.4 cm)

X-1F PRESSURE VESSEL

AS9100, ISO 9001 and FAA Quality Certified PMA Manufacturer

Summary of Contents for IV X-1F

Page 1: ...efore installation The Connector Hose will fit an Owner Supplied Connector T or our optional Saddle T Assembly or Male Run T shown on page 4 Connector branch of Owner Supplied T must have a a a a a Male Compression Thread h h h h h 24 Thread The cold water supply line should be clean and free of construction debris A p p p p p to 1 diameter hole is necessary for mounting the easily installed speci...

Page 2: ...e 5 Install Faucet The X 1F is furnished with General Ecology s exclusive Top Mount Ceramic Disc Faucet If a suitable hole isn t available prepare a hole to install your faucet Cut out Mounting Pattern supplied on page number 6 and use for rough positioning Tape pattern in place then for final positioning place Faucet on pattern on top of sink and check for correct position of faucet body spout an...

Page 3: ...ockwise Close bag and discard Rinse inside of Pressure Vessel 9 Mount unit on Bracket by placing the V Clamp over the raised section on top of the Bracket Open the X 1F Faucet to allow air to exhaust slowly Open Valve on cold water service line Check for leaks Allow water to run for several minutes to clear line and system of air and any loose materials Please note that for the first few days you ...

Page 4: ...ormation requested below No P O Boxes please U P S shipping charges and state taxes will be added where applicable Convenient Order Form Name _________________________________________ Address _______________________________________ City __________________________________________ State ________________________ Zip ___________ Phone ________ ______________________________ Please Print Circle One Cha...

Page 5: ...kitchen faucet and connect diverter valve Attractive Quick Disconnect fitting provides swivel movement of the connector hose routed at right angles for easy positioning and less clutter Our X 1D configuration includes two adapter bushings enabling the diverter to fit approximately 95 of the faucets made in the USA and many overseas Seagull IV X 1P Water Purifier Manual Pump Configuration Ideal for...

Page 6: ... damaged by abrasive cleaners in spite of their hardness To clean faucet surfaces properly use a small amount of a non abrasiveliquiddetergentandasoftwetcloth Gentlyrubthesoiled surface until the dirt is removed Then rinse clean and wipe with a dry soft cloth to remove water drops and to prevent spotting Do not use any abrasive or pumice type cleansers to clean the surfaces of these faucets oryoum...

Reviews: