Momentus 5400.5 SATA Product Manual, Rev. B
9
2.9.1.1
Typical current profile
Figure 1. T5V only startup and operation current profile
2.9.2
Deferred spinup
Momentus 5400.5 SATA drives do not support the deferred spinup option. If you require this option, refer to the
Momentus 5400.3 SATA Blade Server family of drives.
2.9.3
Conducted noise
Input noise ripple is measured at the host system power supply across an equivalent 15-ohm resistive load on
the +5 volt line.
Using 5-volt power, the drive is expected to operate with a maximum of 100 mV peak-to-peak square-wave
injected noise at up to 10 MHz.
Note.
Equivalent resistance is calculated by dividing the nominal voltage by the typical RMS read/write
current.
2.9.4
Voltage tolerance
Voltage tolerance (including noise):
5V
±
5%
Summary of Contents for ST9120310AS
Page 3: ...Momentus 5400 5 SATA Product Manual Rev B i...
Page 4: ...ii Momentus 5400 5 SATA Product Manual Rev B...
Page 6: ...iv Momentus 5400 5 SATA Product Manual Rev B...
Page 8: ......
Page 28: ...20 Momentus 5400 5 SATA Product Manual Rev B...
Page 40: ...32 Momentus 5400 5 SATA Product Manual Rev B...
Page 46: ...38 Momentus 5400 5 SATA Product Manual Rev B...
Page 47: ......