background image

Lyrion Series IDE Product Manual, Rev. B

29

The 512-byte data returned by the Identify Device command is shown in the table below. The last 256-byte are 
vendor specific data and are for reference only.

Word No.

Value

Word No.

Value

Word No.

Value

Word No.

Value

Word No.

Value

Word No.

Value

0

0040

43

2020

86

3C29

129

7C80

172

0000

215

0000

1

3FFF

44

2020

87

6073

130

06FC

173

0000

216

0000

2

8C37

45

2020

88

101F

131

7C80

174

0000

217

0000

3

0010

46

2020

89

002C

132

06FC

175

0000

218

0000

4

0000

47

8010

90

0000

133

2E30

176

0000

219

0000

5

0000

48

0000

91

C0C0

134

3705

177

0000

220

0000

6

003F

49

2B00

92

0001

135

2CBE

178

0000

221

0000

7

06FC

50

4000

93

100D

136

0210

179

0000

222

0000

8

7C80

51

0200

94

8080

137

0000

180

0000

223

0000

9

0000

52

0000

95

0000

138

3C03

181

0000

224

0000

10

2020

53

0007

96

0000

139

3C1E

182

0000

225

0000

11

2020

54

3FFF

97

0000

140

FFFF

183

0000

226

0000

12

2020

55

0010

98

0000

141

400B

184

0000

227

0000

13

2020

56

003F

99

0000

142

0000

185

0000

228

0000

14

2020

57

FC10

100

7C80

143

0000

186

0000

229

0000

15

2020

58

00FB

101

06FC

144

069C

187

0000

230

0000

16

xxxx

59

0110

102

0000

145

02A0

188

0000

231

0000

17

xxxx

60

7C80

103

0000

146

0102

189

0000

232

0000

18

xxxx

61

06FC

104

0000

147

0000

190

0000

233

0000

19

xxxx

62

0000

105

0000

148

0078

191

0000

234

0000

20

0000

63

0407

106

0000

149

0618

192

0000

235

0000

21

0000

64

0003

107

0000

150

0000

193

0000

236

0000

22

0004

65

0078

108

0000

151

0000

194

0000

237

0000

23

xxxx

66

0078

109

0000

152

0000

195

0000

238

0000

24

xxxx

67

0078

110

0000

153

1212

196

0000

239

0000

25

2020

68

0078

111

0000

154

0028

197

0000

240

0000

26

2020

69

0000

112

0000

155

0000

198

0000

241

0000

27

xxxx

70

0000

113

0000

156

0000

199

0000

242

0000

28

xxxx

71

0000

114

0000

157

00C0

200

0000

243

0000

29

xxxx

72

0000

115

0000

158

00E1

201

0000

244

0000

30

xxxx

73

0000

116

0000

159

000A

202

0000

245

0000

31

xxxx

74

0000

117

0000

160

0000

203

0000

246

0000

32

2020

75

0000

118

0000

161

0000

204

0000

247

0000

33

2020

76

0000

119

0002

162

0000

205

0000

248

0000

34

2020

77

0000

120

0000

163

0000

206

0000

249

0000

35

2020

78

0000

121

0000

164

0000

207

0000

250

0000

36

2020

79

0000

122

0000

165

0000

208

0000

251

0000

37

2020

80

00F0

123

0000

166

0000

209

0000

252

0000

38

2020

81

0000

124

0000

167

0000

210

0000

253

0000

39

2020

82

746b

125

0000

168

0000

211

0000

254

0000

40

2020

83

7d29

126

0000

169

0000

212

0000

255

33A5

41

2020

84

6073

127

0000

170

0000

213

0000

42

2020

85

7469

128

0209

171

0000

214

0000

Drive 

Model 

Number

xxxx

xxxx

Serial 

Number

xxxx

Firmware 

Revision

Summary of Contents for ST730212DEG

Page 1: ...Product Manual Lyrion Series IDE 100462437 Rev B May 2007 ST760211DE ST730212DE ...

Page 2: ...ate Technology LLC or one of its affiliated companies in the United States and or other countries All other trademarks or registered trademarks are the property of their respective owners One gigabyte or GB equals one billion bytes when referring to hard drive capacity Accessible capacity may vary depending on operating environment and formatting Seagate reserves the right to change with out notic...

Page 3: ... 11 2 8 6 Vibration 11 2 8 7 Corrosive environment 13 2 9 Acoustics 14 2 10 Electromagnetic immunity 14 2 11 Reliability 14 2 12 Agency certification 15 2 12 1 Safety certification 15 2 12 2 Electromagnetic compatibility 15 2 12 3 European Union Restriction of Hazardous Substances RoHS Directive 15 2 12 4 China Restriction of Hazardous Substances RoHS Directive 16 2 12 5 FCC verification 16 3 0 Co...

Page 4: ...ii Lyrion Series IDE Product Manual Rev B ...

Page 5: ...Figure 3 Location where tri axial accelerometer will be placed on Lyrion Series drives 11 Figure 4 Drive axis definition for Lyrion Series drives 11 Figure 5 Lyrion Series breather hole location 19 Figure 6 Lyrion Series proper handling example 19 Figure 7 Lyrion Series mechanical dimensions top side and end view 21 Figure 8 Lyrion Series Area for Protective Mounting 22 ...

Page 6: ...iv Lyrion Series IDE Product Manual Rev B ...

Page 7: ...600 RPM spindle speed and a 2 Mbyte buffer combined for superior read write performance Quiet operation Fluid Dynamic Bearing FDB motor Perpendicular recording heads and EPRML technology which provide the drives with increased areal density State of the art cache and on the fly error correction algorithms 1500 G nonoperating shock and 500 G operating shock SeaTools diagnostic software performs a d...

Page 8: ...ntial damages including but not limited to loss of use data or profits procurement of substitute goods or services or business interruptions however caused and on any theory of liability whether in contract strict liability or tort including negligence or otherwise arising in any way from the use of this kit even if advised of the possibility of such damage 1 2 Drive care Do not use the Lyrion Ser...

Page 9: ...ack density TPI tracks inch average 165 000 Areal density Gbits inch2 average 169 Spindle speed RPM 3 600 Internal data transfer rate OD Mbits sec max 350 Sustained data transfer rate OD Mbytes sec 24 5 I O data transfer rate Mbytes sec max 66 7 UDMA 4 ATA data transfer modes supported PIO modes 0 4 Multiword DMA modes 0 2 Ultra DMA modes 0 4 Height 5 0 0 15 mm 0 1968 0 006 inches Width 54 0 0 3 m...

Page 10: ...mean sea level max 60 98 m to 12 192 m 200 ft to 40 000 ft Shock operating Gs max at 2 msec 500 Shock nonoperating Gs max at 1 msec 1500 Vibration operating max displacement may apply below 10 hz 1 0 Gs 0 to peak 10 500 Hz 2 oct min sweep rate Vibration nonoperating max displacement may apply below 22 hz 5 0 Gs 0 to peak 10 500 Hz 0 5 oct min sweep rate Idle sound power bels typical 1 6 Operationa...

Page 11: ...165 000 Areal density Gbits inch2 average 169 Spindle speed RPM 0 2 3 600 Internal data transfer rate OD Mbits sec max 350 Sustained data transfer rate OD Mbytes sec max 24 5 I O data transfer rate Mbytes sec max 66 7 UDMA 4 Cache buffer Mbytes 2 Height mm inches 5 0 0 15 0 1968 0 006 Width mm inches 54 0 0 3 2 1260 0 0118 Length mm inches 71 0 0 3 2 7953 0 0118 Typical weight grams pounds 48 0 ty...

Page 12: ... and does not execute a read or write operation Servo electronics are active Seek power is measured based on three random seek operations every 100 msecs Read write mode Read write power is measured with the heads on track while the head is reading writing from to disc It is performed with 100 percent duty cycle of read write operation Performance Idle mode During Performance Idle mode the heads a...

Page 13: ... in 10 msec window 2 7 1 1 Typical current profile Figure 2 Typical 3 3V startup and operation current profile Table 2 DC power Power Consumption at 3 3V Average W Startup max 1 15 Read 1 0 Write 0 9 Performance idle typical 0 5 Low power idle typical 0 3 Standby Sleep typical 0 08 ...

Page 14: ...3 3 volt line Using 3 3 volt power the drive is expected to operate with a maximum of 70 mV peak to peak square wave injected noise at up to 20 MHz Note Equivalent resistance is calculated by dividing the nominal voltage by the typical RMS read write current 2 7 3 Voltage tolerance and Maximum current Voltage tolerance including noise 3 3V 5 Maximum Current peak to peak 500mA ...

Page 15: ...Performance Idle mode when the Advanced Power Management Level is set between 80h and FDh and the Idle timer reaches 15 seconds Disc is spinning and heads are parked and drive accepts all commands and returns to Active mode any time disc access is necessary Standby Sleep mode The drive enters Standby mode when the host sends a Standby Immediate command In Standby mode the drive buffer is disabled ...

Page 16: ...3 1 Relative humidity 2 8 3 2 Wet bulb temperature 1 Operating Wet bulb temperature is calculated by the operating Temperature and the Relative Humidity levels 2 Nonoperating Wet bulb temperature is calculated by the nonoperating Temperature and the Relative Humidity levels 2 8 4 Altitude Operating 0 to 60 C 32 to 140 F 70 C max case temperature Nonoperating 40 to 70 C 40 to 158 F Operating 20 C p...

Page 17: ...ve is subjected to 10 shocks for each direction During the shocks there must be a minimum delay of 3 seconds between shock pulses Soft errors and automatic retries are allowed during the test No data loss or permanent damage occurs during a half sine shock pulse of 500 G 2 msec 2 8 5 2 Nonoperating shock The nonoperating shock level that the drive can experience without incurring any physical dama...

Page 18: ...thout a hard error while being subjected to the following vibration levels 2 8 6 3 Nonoperating sweep sine vibration The following table lists the maximum nonoperating sweep sine vibration levels that the drive may experience while meeting the performance standards specified It consists of a forward and backward sweep from 5 Hz to 500 Hz to 5 Hz The drive does not incur any physical damage when su...

Page 19: ...to uncontrolled chemical pollutants and corro sive chemicals as electronic drive component reliability can be affected by the installation environment The sil ver copper nickel and gold films used in Seagate products are especially sensitive to the presence of sulfide chloride and nitrate contaminants Sulfur is found to be the most damaging In addition electronic components should never be exposed...

Page 20: ...t system the drive operates without errors or degradation in performance when subjected to the radio frequency RF environments defined in the following table 2 11 Reliability Table 6 Drive level acoustics Acoustic mode Idle Operational 1 6 bels typ 2 2 bels typ Table 7 Electromagnetic immunity Test Description Performance level Reference standard Radiated RF immunity 80 to 1 000 MHz 3 V m 80 AM wi...

Page 21: ... these drives have the Korea Ministry of Information and Communication MIC logo they comply with para graph 1 of Article 11 of the Electromagnetic Compatibility control Regulation and meet the Electromagnetic Compatibility EMC Framework requirements of the Radio Research Laboratory RRL Ministry of Information and Communication Republic of Korea These drives have been tested and comply with the Ele...

Page 22: ...ove to ensure that the total assembly enclosure disc drive motherboard power supply etc does comply with the limits for a Class B computing device pursuant to Subpart J Part 15 of the FCC rules Operation with noncertified assemblies is likely to result in interference to radio and television reception Radio and television interference This equipment generates and uses radio frequency energy and if...

Page 23: ...itional sug gestions You may find helpful the following booklet prepared by the Federal Communications Commission How to Identify and Resolve Radio Television Interference Problems This booklet is available from the Super intendent of Documents U S Government Printing Office Washington DC 20402 Refer to publication num ber 004 000 00345 4 ...

Page 24: ...18 Lyrion Series IDE Product Manual Rev B ...

Page 25: ...breather hole location Keep the drive in the electrostatic discharge ESD bag until you are ready for installation to limit the drive s exposure to ESD Before handling the drives put on a grounded wrist strap or ground yourself frequently by touching the metal chassis of a computer that is plugged into a grounded outlet Wear a grounded wrist strap throughout the entire installation procedure Handle...

Page 26: ...ve in the protective casing when not in use Turn the power off before installing or removing the drive Do not apply any force to the drive during handling or installation Do not touch the connector pins or the printed circuit board Do not drop the drive Do not expose the drive to wet conditions Do not place the drive near a strong magnetic field Do not expose the drive to extreme temperatures The ...

Page 27: ... Follow instructions for the installation of data storage devices provided with your device s user manual Do not obstruct the breather hole on the drive see Figure 5 Handle the drive only by its edges or frame or designated finger grip region during mounting see Figure 6 Figure 7 Lyrion Series mechanical dimensions top side and end view X Temperature Measurement Position ...

Page 28: ...can be operated in any orientation but horizontal or vertical orientation is preferred Allow a minimum clearance of 0 012 inches 0 30 mm around the entire perimeter of the drive for cooling with the exception of the mounting edges for better airflow In case the system design warrants bending of the FPC to the hard disc drive care should be taken to maximize the radius Mounting materials are availa...

Page 29: ...nector Table 8 40 way ZIF IDE interface connector signals Pin number Signal Name Description 1 Reserved 2 Reserved 3 RESET Hard Reset 4 GROUND Ground 5 DD07 Data bus bit 7 6 DD08 Data bus bit 8 7 DD06 Data bus bit 6 8 DD09 Data bus bit 9 9 DD05 Data bus bit 5 10 DD10 Data bus bit 10 11 DD04 Data bus bit 4 12 DD11 Data bus bit 11 13 DD03 Data bus bit 3 14 DD12 Data bus bit 12 15 DD02 Data bus bit 2...

Page 30: ...UND Ground 27 IORDY DDMARDY DSTROBE I O Channel Ready during register access Flow control during Ultra DMA data out burst Data in strobe signal for Ultra DMA data in burst 28 GROUND Ground 29 DMACK DMA Acknowledge 30 INTRQ Interrupt Request 31 DA01 Address bus bit 1 32 PDIAG 33 DA00 Address bus bit 0 34 DA02 Address bus bit 2 35 CS0 Chip Select 0 36 CS1 Chip Select 1 37 DASP Used to drive external...

Page 31: ... 35h DMA data out Set Max Address Ext 37h Non data Write Multiple Ext 39h PIO data out Read Verify Sector s 40h Non data Read Verify Sector s Ext 42h Non data Execute Drive Diagnostics 90h Non data Download Microcode 92h PIO data out SMART B0h SMART Disable Operations Non data SMART Enable Disable Autosave Non data SMART Enable Operations Non data SMART Execute Off Line Immediate Non data SMART Re...

Page 32: ...ta Sleep E6h Non data Flush Cache E7h Non data Flush Cache Ext EAh Non data Write Buffer E8h PIO data out Identify Device ECh PIO data in Set Features EFh Non data Security Set Password F1h PIO data out Security Unlock F2h PIO data out Security Erase Prepare F3h Non data Security Erase Unit F4h PIO data out Security Freeze Lock F5h Non data Security Disable Password F6h PIO data out Read Native Ma...

Page 33: ...upported 2B00h 53 Bit 2 1 the fields reported in word 88 are valid Bit 1 1 the fields reported in words 70 64 are valid 0007h 59 Bit 8 1 Multiple sector setting is valid Bits 7 0 Current setting for number of sectors transferred during a Read Write Multiple command 0110h 60 61 Total number of user addressable LBA sectors available 37E3E40h 30GB 6FC7C80h 60GB 63 Bit 10 1 Multiword DMA mode 2 is sel...

Page 34: ...SMART self test supported Bit 0 1 SMART error logging supported 6063h 85 Command sets referred in word 82 enabled xxxxh 86 Command sets referred in word 83 enabled xxxxh 87 Command set feature default Bit 5 1 General Purpose Logging feature supported Bit 1 1 SMART self test supported Bit 0 1 SMART error logging supported 6063h 88 Bit 12 1 Ultra DMA mode 4 is selected 0 Ultra DMA mode 4 is not sele...

Page 35: ... 0102 189 0000 232 0000 18 xxxx 61 06FC 104 0000 147 0000 190 0000 233 0000 19 xxxx 62 0000 105 0000 148 0078 191 0000 234 0000 20 0000 63 0407 106 0000 149 0618 192 0000 235 0000 21 0000 64 0003 107 0000 150 0000 193 0000 236 0000 22 0004 65 0078 108 0000 151 0000 194 0000 237 0000 23 xxxx 66 0078 109 0000 152 0000 195 0000 238 0000 24 xxxx 67 0078 110 0000 153 1212 196 0000 239 0000 25 2020 68 0...

Page 36: ...abled Hardware Reset Current setting Software Reset Current setting Software Reset Current setting Feature Description 02h Enable Write Cache 03h Set DMA and PIO transfer modes based on the value in the Sector Count register Sector Count register values 08h Set PIO Transfer Mode 0 09h Set PIO Transfer Mode 1 0Ah Set PIO Transfer Mode 2 0Bh Set PIO Transfer Mode 3 0Ch Set PIO Transfer Mode 4 20h Se...

Page 37: ...rdware Reset and Software Reset Table 11 Register default values Power On Reset Hardware Reset Software Reset Error register 01h 01h 01h Sector Count register 01h 01h 01h Sector Number register 01h 01h 01h Cylinder Lo register 00h 00h 00h Cylinder Hi register 00h 00h 00h Device Head register 00h 00h 00h Status register 50h 50h 50h Alt Status register 50h 50h 50h ...

Page 38: ...32 Lyrion Series IDE Product Manual Rev B ...

Page 39: ...s with product information program benefits and sales tools You may register for customized communications that are not available on the web These communications contain product launch EOL pricing promotions and other channel related information To learn more about the benefits or to register go to spp seagate com any time from anywhere in the world Seagate Service Centers Presales Support Our Pre...

Page 40: ...ailable on a global basis for the return of defective products Contact your customer support representative for the location nearest you USA Canada Latin America support services For an extensive list of telephone numbers to technical support presales and warranty service in USA Canada Latin America including business hours go to the Contact Us page on www seagate com Global Customer Support Presa...

Page 41: ...on feedback survey We are interested in your comments and suggestions regarding this publication Please take a few minutes to participate in our survey at the following URL http survey seagate com survey techpubs nsf Thank you for your time and comments ...

Page 42: ...36 Lyrion Series IDE Product Manual Rev B ...

Page 43: ...ectromagnetic Compatibility Directive 15 electromagnetic immunity 14 EMC compliance 15 enclosures 16 environmental specifications 10 EPRML 1 error correction algorithms 1 errors 14 EU RoHS directive 15 European Union 15 F FCC verification 16 Features register 30 formatted capacity 4 frequency 14 G guaranteed sectors 4 H handling 19 heads 1 height 5 humidity 10 I I O data transfer rate 5 Identify D...

Page 44: ...equency RF 14 read errors 14 read write mode 6 recording and interface technology 5 recording density 5 recording heads 1 recording method 5 register 30 register default values 31 relative humidity 10 reliability 14 resistance 8 RF 14 RoHS 15 16 S safety certification 15 SeaTools 1 sectors 4 seek mode 6 Set Features command 30 shock 11 signals 23 sleep mode 6 sound 14 specifications 3 spindle spee...

Page 45: ......

Page 46: ...Seagate Technology LLC 920 Disc Drive Scotts Valley California 95066 4544 USA Publication Number 100462437 Rev B Printed in U S A ...