2.9
Environmental specifications
2.9.1
Drive case temperature
Above 1,000 feet (305 meters), the maximum temperature is derated linearly to 112°F (44°C) at 10,000 feet
(3,048 meters).
Drive case temperature should be measured at the location indicated in Figure 4 on page 19.
* Ambient temperature is defined as the temperature of the environment immediately surrounding the drive.
2.9.2
Temperature gradient
2.9.3
Humidity
2.9.3.1
Relative humidity
2.9.3.2
Wet bulb temperature
2.9.4
Altitude
Operating (Drive case temperature)
0° to 75°C (32° to 167°F)
Nonoperating (Ambient
*
)
–40° to 70°C (–40° to 158°F)
Operating:
20°C per hour (68°F per hour max), without condensation
Nonoperating:
30°C per hour (86°F per hour max)
Operating:
5% to 90% noncondensing (30% per hour max)
Nonoperating:
5% to 95% noncondensing (30% per hour max)
Operating:
37.7°C (99.9°F max)
Nonoperating:
40.0°C (104°F max)
Operating:
–60.96 m to 3,048 m (–200 ft. to 10,000+ ft.)
Nonoperating:
–60.96 m to 12,192 m (–200 ft. to 40,000+ ft.)