10
ST310014ACE Product Manual, Rev. B
1.8.3 Humidity
1.8.3.1 Relative Humidity
1.8.3.2 Wet bulb temperature
1.8.4 Altitude
1.8.5 Shock
All shock specifications assume that the drive is mounted securely with
the input shock applied at the drive mounting screws. Shock may be
applied in the X, Y or Z axis.
1.8.5.1 Operating shock
These drives comply with the performance levels specified in this docu-
ment when subjected to a maximum operating shock of 63 Gs (based
on half-sine shock pulses of 2 msec). Shocks should not be repeated
more than two times per second.
1.8.5.2 Nonoperating shock
The nonoperating shock level that the drive can experience without
incurring physical damage or degradation in performance when subse-
quently put into operation is 350 Gs (based on nonrepetitive half-sine
shock pulses of 1 and 2 msec duration).
1.8.6 Vibration
All vibration specifications assume that the drive is mounted securely
with the input vibration applied at the drive mounting screws. Vibration
may be applied in the X, Y or Z axis.
Operating
5% to 90% noncondensing (30% per hour max)
Nonoperating
5% to 95% noncondensing (30% per hour max)
Operating
29.4°C (84°F) max
Nonoperating
40.0°C (104°F) max
Operating
–60.96 m to 3,048 m (–200 ft to 10,000+ ft)
Nonoperating
–121.92 m to 12,192 m (–400 ft to 40,000+ ft)
Summary of Contents for ST310014ACE
Page 1: ...ST310014ACE Ultra ATA Interface Drive Product Manual...
Page 2: ......
Page 3: ...ST310014ACE Ultra ATA Interface Drive Product Manual...
Page 8: ...viii ST310014ACE Product Manual Rev B...
Page 38: ...30 ST310014ACE Product Manual Rev B...