background image

ii

Momentus 5400.3 PSD SATA Product Manual, Rev. A

Summary of Contents for Momentus 5400.3 PSD SATA

Page 1: ...PRODUCT MANUAL Momentus 5400 3 PSD SATA 100454328 Rev A April 2007 ST91608220AS ST91208220AS ST91008220AS ST9808212AS ST9608210AS...

Page 2: ...United States and or other countries All other trademarks or registered trademarks are the property of their respective owners One gigabyte or GB equals one billion bytes when referring to hard drive...

Page 3: ...Momentus 5400 3 PSD SATA Product Manual Rev A i Revision status summary sheet Revision Date Notes Rev A 04 13 07 Initial release...

Page 4: ...ii Momentus 5400 3 PSD SATA Product Manual Rev A...

Page 5: ...ent 13 2 10 3 Humidity 13 2 10 4 Altitude 13 2 10 5 Shock 14 2 10 6 Vibration 14 2 11 Acoustics 15 2 12 Electromagnetic immunity 15 2 13 Reliability 16 2 14 Agency certification 16 2 14 1 Safety certi...

Page 6: ...iv Momentus 5400 3 PSD SATA Product Manual Rev A...

Page 7: ...roduct Manual Rev A v List of Figures Figure 1 Typical 5V only startup and operation current profile 11 Figure 2 Serial ATA connectors 20 Figure 3 Attaching SATA cabling 20 Figure 4 Mounting dimension...

Page 8: ......

Page 9: ...provides the drives with increased areal density State of the art SDRAM buffer and on the fly error correction algorithms Full track multiple sector transfer capability without local processor interve...

Page 10: ...is is not a typical Serial ATA environment The Serial ATA host adapter and drive share the function of emulating parallel ATA device behavior to provide backward compatibility with existing host syste...

Page 11: ...time the discs are spinning in the HDA Improve reliability Shock and vibration impacts during writes is negligible when writing to NVC memory This results in an overall Annualized Failure Rate AFR of...

Page 12: ...4 Momentus 5400 3 PSD SATA Product Manual Rev A...

Page 13: ...808 234 441 648 195 371 568 156 301 488 117 210 240 Bytes per sector 512 Physical read write heads 4 3 3 2 2 Discs 2 2 2 1 1 Non volitile cache Mbytes 256 SDRAM buffer Mbytes 8 Recording density bits...

Page 14: ...max at 0 5 msec 400 Vibration operating 1 0 G 0 to peak 5 500 Hz Vibration nonoperating 5 Gs 0 to peak 5 500 Hz Drive acoustics sound power bels Idle 2 4 typical 2 6 max 2 2 typical 2 4 max Performan...

Page 15: ...g on operating environment and formatting 2 2 1 LBA mode When addressing these drives in LBA mode all blocks sectors are consecutively numbered from 0 to n 1 where n is the number of guaranteed sector...

Page 16: ...56 MB Interface Serial ATA SATA Recording method Perpendicular Recording density BPI bits inch max 870k Track density TPI tracks inch max 150k Areal density Gbits inch2 max 132 Spindle speed RPM 0 2 5...

Page 17: ...overhead Note These drives are designed to consistently meet the seek times represented in this manual Physical seeks regardless of mode such as track to track and average are expected to meet the no...

Page 18: ...m seek operations every 100 msecs This mode is not typical Read write power and current Read write power is measured with the heads on track based on three 63 sector read or write operations every 100...

Page 19: ...0 3 SATA Blade Server family of drives 2 9 3 Conducted noise Input noise ripple is measured at the host system power supply across an equivalent 15 ohm resistive load on the 5 volt line Using 5 volt p...

Page 20: ...sc access is necessary Sleep mode The drive enters Sleep mode after receiving a Sleep command from the host In Sleep mode the drive buffer is in Self Refresh Low Power mode the heads are parked and th...

Page 21: ...C every 1000 feet 2 10 2 Temperature gradient 2 10 3 Humidity 2 10 3 1 Relative humidity 2 10 3 2 Wet bulb temperature 2 10 4 Altitude Operating 0 to 60 C 32 to 140 F Nonoperating 40 to 70 C 40 to 158...

Page 22: ...en subsequently put into operation is 900 Gs based on a nonrepetitive half sine shock pulse of 1 msec duration The nonoperating shock level that the drive can experience without incurring physical dam...

Page 23: ...n performance when subjected to the radio frequency RF environments defined in the following table Table 5 Drive level acoustics Models Idle Performance seek 2 discs ST91608220AS ST91208220AS ST910082...

Page 24: ...uarantee that all systems will comply with the directives The drive is designed for operation inside a properly designed enclosure with properly shielded I O cable if necessary and terminators on all...

Page 25: ...to ensure that the total assembly enclosure disc drive motherboard power supply etc does comply with the limits for a Class B computing device pursuant to Subpart J Part 15 of the FCC rules Operation...

Page 26: ...nclude standard operat ing procedures that ensure that restricted substances are not utilized in our manufacturing operations labora tory analytical validation testing and an internal auditing process...

Page 27: ...ore handling the drive put on a grounded wrist strap or ground yourself frequently by touching the metal chassis of a computer that is plugged into a grounded outlet Wear a grounded wrist strap throug...

Page 28: ...for factory use only Figure 2 Serial ATA connectors 3 3 Serial ATA cables and connectors The Serial ATA interface cable consists of four conductors in two differential pairs plus three ground connec...

Page 29: ...ended Measurements shown in Figure 4 are in inches Figure 4 Mounting dimensions top side and end view BOTH SIDES 2 2 12 MIN FULL THREAD 2X M3 X 0 5 6H MOUNTING HOLES BOTH SIDES 0 148 010 X 90 4X M3 X...

Page 30: ...22 Momentus 5400 3 PSD SATA Product Manual Rev A...

Page 31: ...5400 3 PSD SATA drives incorporate connectors which enable you to hot plug these drives in accordance with the Serial ATA High Speed Serialized AT Attachment specification revision 2 0 This specifi c...

Page 32: ...n a blind mate backplane configuration 4 All used voltage pins Vx must be terminated Power P1 V33 3 3V power P2 V33 3 3V power P3 V33 3 3V power pre charge 2nd mate P4 Ground 1st mate P5 Ground 2nd ma...

Page 33: ...B1h C1h Device Configuration Identify B1h C2h Device Configuration Set B1h C3h Download Microcode 92h Execute Device Diagnostics 90h Flush Cache E7h Flush Cache Extended EAh Identify Device ECh Initi...

Page 34: ...D4h S M A R T Read Attribute Thresholds B0h D1h S M A R T Read Data B0h D0h S M A R T Read Log Sector B0h D5h S M A R T Return Status B0h DAh S M A R T Save Attribute Values B0h D3h S M A R T Write At...

Page 35: ...Security Freeze Lock F5h Security Disable Password F6h Non volitile cache commands Set NV Cache Power Mode Non data B6h 00h Return from NV Cache Power Mode Non data B6h 01h Add LBAs to NV Cache Pinne...

Page 36: ...ved 0C5AH 1 Number of logical cylinders 16 383 2 ATA reserved 0000H 3 Number of logical heads 16 4 Retired 0000H 5 Retired 0000H 6 Number of logical sectors per logical track 63 003FH 7 9 Retired 0000...

Page 37: ...word 120 nsec 0078H 66 Recommended multiword DMA transfer cycle time per word 120 nsec 0078H 67 Minimum PIO cycle time without IORDY flow control 240 nsec 00F0H 68 Minimum PIO cycle time with IORDY f...

Page 38: ...H 255 Integrity word xxA5H Note See the bit descriptions below for words 63 88 93 and 94 of the Identify Drive data Description if bit is set to 1 Bit Word 63 0 Multiword DMA mode 0 is supported 1 Mul...

Page 39: ...res are as indi cated above Bit Word 93 13 1 80 conductor cable detected CBLID above VIH 0 40 conductor cable detected CBLID below VIL Table 8 Set Features command values 02H Enable write cache defaul...

Page 40: ...rive returns The diagnostic software ships with all new drives and is also available at http seatools seagate com This drive is shipped with S M A R T features disabled You must have a recent BIOS or...

Page 41: ...ers with product information program benefits and sales tools You may register for customized communications that are not available on the web These communications contain product launch EOL pricing p...

Page 42: ...available on a global basis for the return of defective products Contact your customer support representative for the location nearest you USA Canada Latin America support services For an extensive l...

Page 43: ...5 Configuring the drive 19 connectors 20 CSA C22 2 950 16 current 6 cycles 16 Cylinders 7 D data transfer rates 1 DC power 10 Default logical geometry 7 density 5 Device Configuration Freeze Lock 25 D...

Page 44: ...e 11 nominal power 9 Nonoperating shock 14 Nonoperating vibration 14 Nonrecoverable read errors 6 nonrecoverable read errors 16 Non volatile cache 2 Non volitile cache sizes 8 NVC 2 O Operating shock...

Page 45: ...A interface 23 serial ATA ports 2 servo electronics 10 Set Drive Parameters 25 Set Features 25 Set Max Address 26 Set Multiple Mode 26 Shock 14 Shock nonoperating 6 Shock operating 6 single track seek...

Page 46: ...38 Momentus 5400 3 PSD SATA Product Manual Rev A...

Page 47: ......

Page 48: ...Seagate Technology LLC 920 Disc Drive Scotts Valley California 95066 4544 USA Publication Number 100454328 Rev A Printed in USA...

Reviews: