![Seagate Medalist Pro 4520 Product Manual Download Page 35](http://html1.mh-extra.com/html/seagate/medalist-pro-4520/medalist-pro-4520_product-manual_1223117035.webp)
3.2
Command set
This section lists all of the ATA commands the drives use. Only the
commands with unique implementation for the drives are discussed in
this manual. For information about the ATA interface, refer to
X3T13.1153D Rev. 9, Information Technology—AT Attachment-4 Inter-
face specification.
The table below lists all commands implemented in the drives. It uses
the following abbreviations:
FR
Features register
SC
Sector Count register
SN
Sector Number register
CY
Cylinder register
DH
Drive/Head register
n
This register does not contain a valid parameter for this
command.
y
This register contains a valid parameter for this command. In
the Drive/Head register, both the drive and head parameters
are valid for this command.
D
The Drive/Head register contains a valid drive parameter for
this command. The head parameter is not valid for this
command.
Note. Read DMA, Read Long, Read Sector, Read Verify Sector, Write
DMA, Write Long and Write Sector support with retry and without
retry commands.
Command name
Command
code (in hex)
Parameters used
FR SC SN CY DH
Active and Set Idle Timer
FB
n
y
n
n
D
Active Immediate
F9
n
n
n
n
D
Check Idle Mode
FD
n
y
n
n
D
Check Power Mode
98, E5
n
y
n
n
D
Execute Drives Diagnostic
90
n
n
n
n
D
Identify drives
EC
n
n
n
n
D
Idle
97, E3
n
y
n
n
D
continued
Medalist Pro 9140, 6530 and 4520 Product Manual, Rev. B
27
Summary of Contents for Medalist Pro 4520
Page 2: ......
Page 8: ...vi Medalist Pro 9140 6530 and 4520 Product Manual Rev B...
Page 32: ...24 Medalist Pro 9140 6530 and 4520 Product Manual Rev B...
Page 46: ...38 Medalist Pro 9140 6530 and 4520 Product Manual Rev B...
Page 51: ......
Page 52: ......
Page 53: ......