Medalist 13640, 10230, 6422 and 3210 Product Manual, Rev. B
11
Sleep mode. The drive enters Sleep mode after receiving a Sleep
command from the host. The heads are parked and the spindle is at rest.
The drive leaves Sleep mode after it receives a Hard Reset or Soft Reset
from the host. After receiving a reset, the drive exits Sleep mode and
enters Active mode with all current translation parameters intact.
Idle and Standby timers. Each time the drive performs an Active
function (read, write or seek), the standby timer is reinitialized and begins
counting down from its specified delay times to zero. If the standby timer
reaches zero before any drive activity is required, the drive makes a
transition to Standby mode. In both Idle and Standby mode, the drive
accepts all commands and returns to Active mode when disc access is
necessary.
1.8 Environmental tolerances
1.8.1 Ambient temperature
Note. Above 1,000 feet (305 meters), the maximum temperature is
derated linearly to 112°F (44°C) at 10,000 feet (3,048 meters).
Operating ambient temperature is defined as the temperature of
the environment immediately surrounding the drive.
1.8.2 Temperature gradient
1.8.3 Humidity
1.8.3.1 Relative Humidity
1.8.3.2 Wet bulb temperature
Operating
5° to 55°C (41° to 131°F)
Nonoperating
–40° to 70°C (–40° to 158°F)
Operating
20°C/hr (36°F/hour) max, without condensation
Nonoperating
20°C/hr (36°F/hour) max, without condensation
Operating
8% to 90% noncondensing (10% per hour max)
Nonoperating
5% to 95% noncondensing (10% per hour max)
Operating
29.4°C (84°F) max
Nonoperating
29.4°C (84°F) max
Summary of Contents for Medalist 10230
Page 2: ......
Page 8: ...vi Medalist 13640 10230 6422 and 3210 Product Manual Rev B...
Page 24: ...16 Medalist 13640 10230 6422 and 3210 Product Manual Rev B...
Page 28: ...20 Medalist 13640 10230 6422 and 3210 Product Manual Rev B...
Page 39: ...Medalist 13640 10230 6422 and 3210 Product Manual Rev B 31...