1.8.6.2 Nonoperating
vibration
The following table lists the maximum nonoperating vibration that the
drive may experience without incurring physical damage or degradation
in performance when put into operation.
5–22 Hz
0.162-inch displacement (double amplitude)
22–450 Hz
4 Gs acceleration (peak)
450–22 Hz
4 Gs acceleration (peak)
22–5 Hz
0.162-inch displacement (double amplitude)
1.9
Drive acoustics
Drive acoustics are measured as sound pressure 1 meter from the drive.
Mode
Typical
Maximum
Idle mode (dBA)
26
30
Seek (dBA)
29
33
1.10 Reliability
Nonrecoverable read errors
1 per 10
13
bits read
Mean time between failures
300,000 power-on hours
(nominal power, at sea level,
25°C ambient temperature)
Contact start-stop cycles
50,000 cycles
(at nominal voltage and temperature,
with 60 cycles per hour and a 50%
duty cycle)
Preventive maintenance
None required
Service life
5 years