level. Active mode current and power are measured with a 32-msec delay
between each operation and the drive in default logical geometry.
Seeking power and currents are measured during one-third-stroke buff-
ered seeks. Read/Write power and current are measured with the heads
on track, based on a 16-sector write followed by a 32-msec delay, then
a 16-sector read followed by a 32-msec delay. Spinup power is measured
from time of power-on to time of drive-ready for normal operation.
Mode
Typical watts RMS
(at nominal voltage)
Typical amps RMS
(at nominal voltage)
Spinup
3.50
0.700
Active
Seeking
Read/Write
2.10
2.10
0.420
0.420
Idle
1.30
0.260
Standby
0.40
0.080
Sleep
0.30
0.060
1.7.1.1 Typical
current
profile
Figure 1 shows a typical current profile for the ST9816AG.
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
0
1
2
3
4
5
5
6
7
8
9
10
11
12
13
Spinup
Upload code
Drive ready
Idle
Standby
mode
mode
Sleep
mode
Active
mode
Current (Amps)
Time (seconds)
Figure 1. Typical startup and operation current profile for the ST9816AG