Lyve Rack R1 Installation Guide
36
Item number
Name
Description
5
NIC LED
Indicates network activity on the LAN1 when flashing.
6
NIC LED
Indicates network activity on the LAN2 when flashing.
7
Information LED
Alerts operator to several states, as noted in the table
below.
8
UID button
Unit identifier button illuminates the Information LED with
status noted below.
Table 10: Different status of information LED of the server
Status
Description
Continuously on and red
An overheat condition has occurred.
(This may be caused by cable congestion.)
Blinking red (1Hz)
Fan failure. Check for an inoperative fan.
Blinking red (0.25Hz)
Power failure. Check for a non-operational power supply.
Solid blue
UID has been activated locally to locate the server in a rack
environment.
Blinking blue
UID has been activated using IPMI to locate the server in a
rack environment
To switch ON servers A and B:
1.
Push the front panel power button to switch ON server A.
2.
Push the front panel power button to switch ON server B.
3.
Verify that both servers are switched ON correctly by referring to the following LED check
diagram.
Power LED is solid green.
HDD LED flashes green when accessing drives.
LAN2 LED flashes amber to show 1Gb/s network activity (flash green for 100 Mb/s).