background image

20

Lyrion Series IDE Product Manual, Rev. F

Figure 8.

Lyrion Series FPC dimensions

3.3

Mounting considerations

• Use an elastic mounting material to protect drives so as to ensure that more shock can be absorbed.
• There are guides along the side for mounting. Refer to figure on areas (refer to Figure 9, shaded area)

where the mounting material can rest for mounting.

• As the drive is a sensitive device, it is not recommended to have any mounting force on the top and bottom 

surface of the drive other than the recommended mounting surfaces. Mounting force on non recommended 
surfaces shall not exceed 6.8N.”

• The drive can be operated in any orientation but horizontal or vertical orientation is preferred.
• Allow a minimum clearance of 0.012 inches (0.30 mm) around the entire perimeter of the drive for cooling, 

with the exception of the mounting edges for better airflow.

• In case the system design warrants bending of the FPC to the hard disc drive, care should be taken to 

maximize the radius.

• Mounting materials are available from many third-party vendors.
• The 40-way connector is design to meet minimum 6N Horizontal FPC retention after mating.
• The connector has a specification of 20 insertion cycles.

Figure 9.

Lyrion Series Area for Protective Mounting

Summary of Contents for Lyrion Series IDE Drive ST730212DE-30GB

Page 1: ...Product Manual Lyrion Series IDE 100441946 Rev F September 2007 ST760211DE ST740211DE ST730212DE...

Page 2: ...ompanies in the United States and or other countries All other trademarks or registered trademarks are the property of their respective owners One gigabyte or GB equals one billion bytes when referrin...

Page 3: ...ck 10 2 8 6 Vibration 10 2 8 7 Corrosive environment 12 2 9 Acoustics 12 2 10 Electromagnetic immunity 13 2 11 Reliability 13 2 12 Agency certification 14 2 12 1 Safety certification 14 2 12 2 Electro...

Page 4: ...ii Lyrion Series IDE Product Manual Rev F...

Page 5: ...re tri axial accelerometer will be placed on Lyrion Series drives 10 Figure 4 Drive axis definition for Lyrion Series drives 10 Figure 5 Lyrion Series breather hole location 17 Figure 6 Lyrion Series...

Page 6: ...iv Lyrion Series IDE Product Manual Rev F...

Page 7: ...returns Figure 1 Lyrion Series IDE interface disc drive 1 1 Disclaimer Seagate Technology LLC makes no warranties whatsoever including any warranty of merchantability non infringement fitness for any...

Page 8: ...2 Lyrion Series IDE Product Manual Rev F...

Page 9: ...rage 1 025 000 Track density TPI tracks inch average 165 000 Areal density Gbits inch2 average 169 Spindle speed RPM 3 600 Internal data transfer rate OD Mbits sec max 350 Sustained data transfer rate...

Page 10: ...ck operating Gs max at 2 msec 500 Shock nonoperating Gs max at 1 msec 1500 Vibration operating max displacement may apply below 10 hz 1 0 Gs 0 to peak 10 500 Hz 2 oct min sweep rate Vibration nonopera...

Page 11: ...65 000 Areal density Gbits inch2 average 169 Spindle speed RPM 0 2 3 600 Internal data transfer rate OD Mbits sec max 350 Sustained data transfer rate OD Mbytes sec max 24 5 I O data transfer rate Mby...

Page 12: ...and does not execute a read or write operation Servo electronics are active Seek power is measured based on three random seek operations every 100 msecs Read write mode Read write power is measured wi...

Page 13: ...in 10 msec window 2 7 1 1 Typical current profile Figure 2 Typical 3 3V startup and operation current profile Table 2 DC power Power Consumption at 3 3V Average W Startup max 1 15 Read 1 0 Write 0 9 P...

Page 14: ...ower idle mode Drive enters Low Power Idle mode from Performance Idle mode when the Advanced Power Management Level is set between 80h and FDh and the Idle timer reaches 2 seconds default setting Disc...

Page 15: ...1 Relative humidity 2 8 3 2 Wet bulb temperature 1 Operating Wet bulb temperature is calculated by the operating Temperature and the Relative Humidity levels 2 Nonoperating Wet bulb temperature is cal...

Page 16: ...e is subjected to 10 shocks for each direction During the shocks there must be a minimum delay of 3 seconds between shock pulses Soft errors and automatic retries are allowed during the test No data l...

Page 17: ...hout a hard error while being subjected to the following vibration levels 2 8 6 3 Nonoperating sweep sine vibration The following table lists the maximum nonoperating sweep sine vibration levels that...

Page 18: ...mponents should never be exposed to condensing water on the surface of the printed circuit board assembly PCBA or exposed to an ambient relative humidity greater than 95 percent Materials used in cabi...

Page 19: ...900 MHz 3 V m 50 pulse modulation 200 Hz A EN 61000 4 3 96 ENV 50204 95 Electrical fast transient 1 kV on AC mains 0 5 kV on external I O B EN 61000 4 4 95 Surge immunity 1 kV differential 2 kV commo...

Page 20: ...ned for operation inside a properly designed enclosure with properly shielded I O cable if necessary and terminators on all unused I O ports Computer manufacturers and system integrators should confir...

Page 21: ...ed with components and materials that comply with the RoHS Directive 2 12 4 China Restriction of Hazardous Substances RoHS Directive This product has an Environmental Protection Use Period EPUP of 20...

Page 22: ...tructions may cause interference to radio and television reception This equipment is designed to provide reasonable protection against such interference in a residential installa tion However there is...

Page 23: ...reather hole location Keep the drive in the electrostatic discharge ESD bag until you are ready for installation to limit the drive s exposure to ESD Before handling the drives put on a grounded wrist...

Page 24: ...e in the protective casing when not in use Turn the power off before installing or removing the drive Do not apply any force to the drive during handling or installation Do not touch the connector pin...

Page 25: ...with your device s user manual Do not obstruct the breather hole on the drive see Figure 5 Handle the drive only by its edges or frame or designated finger grip region during mounting see Figure 6 Fi...

Page 26: ...ng surfaces Mounting force on non recommended surfaces shall not exceed 6 8N The drive can be operated in any orientation but horizontal or vertical orientation is preferred Allow a minimum clearance...

Page 27: ...DD07 Data bus bit 7 6 DD08 Data bus bit 8 7 DD06 Data bus bit 6 8 DD09 Data bus bit 9 9 DD05 Data bus bit 5 10 DD10 Data bus bit 10 11 DD04 Data bus bit 4 12 DD11 Data bus bit 11 13 DD03 Data bus bit...

Page 28: ...a DMA data in burst 28 GROUND Ground 29 DMACK DMA Acknowledge 30 INTRQ Interrupt Request 31 DA01 Address bus bit 1 32 PDIAG 33 DA00 Address bus bit 0 34 DA02 Address bus bit 2 35 CS0 Chip Select 0 36...

Page 29: ...35h DMA data out Set Max Address Ext 37h Non data Write Multiple Ext 39h PIO data out Read Verify Sector s 40h Non data Read Verify Sector s Ext 42h Non data Execute Drive Diagnostics 90h Non data Dow...

Page 30: ...de E5h Non data Sleep E6h Non data Flush Cache E7h Non data Write Buffer E8h PIO data out Identify Device ECh PIO data in Set Features EFh Non data Security Set Password F1h PIO data out Security Unlo...

Page 31: ...2B00h 53 Bit 2 1 the fields reported in word 88 are valid Bit 1 1 the fields reported in words 70 64 are valid 0007h 59 Bit 8 1 Multiple sector setting is valid Bits 7 0 Current setting for number of...

Page 32: ...lf test supported Bit 0 1 SMART error logging supported 6063h 85 Command sets referred in word 82 enabled xxxxh 86 Command sets referred in word 83 enabled xxxxh 87 Command set feature default Bit 5 1...

Page 33: ...Count register values 08h Set PIO Transfer Mode 0 09h Set PIO Transfer Mode 1 0Ah Set PIO Transfer Mode 2 0Bh Set PIO Transfer Mode 3 0Ch Set PIO Transfer Mode 4 20h Set Multiword Transfer Mode 0 21h...

Page 34: ...28 Lyrion Series IDE Product Manual Rev F...

Page 35: ...with product information program benefits and sales tools You may register for customized communications that are not available on the web These communications contain product launch EOL pricing prom...

Page 36: ...Centers are available on a global basis for the return of defective products Contact your customer support representative for the location nearest you USA Canada Latin America support services For an...

Page 37: ...ctromagnetic Compatibility Directive 14 electromagnetic immunity 13 EMC compliance 14 enclosures 16 environmental specifications 9 EPRML 1 error correction algorithms 1 errors 13 EU RoHS directive 15...

Page 38: ...6 radio frequency RF 13 read errors 13 read write mode 6 recording and interface technology 5 recording density 5 recording heads 1 recording method 5 register 27 relative humidity 9 reliability 13 re...

Page 39: ......

Page 40: ...Seagate Technology LLC 920 Disc Drive Scotts Valley California 95066 4544 USA Publication Number 100441946 Rev F Printed in U S A...

Reviews: