background image

Seagate IronWolf Pro v6 Serial ATA Product Manual, Rev. C

  21

  

Korean RRA

If these drives have the Korean Communications Commission (KCC) logo, they comply with paragraph 1 of Article 11 of the

 

Electromagnetic Compatibility control Regulation and meet the Electromagnetic Compatibility (EMC) Framework requirements of 
the Radio Research Agency (RRA) Communications Commission, Republic of Korea.

These drives have been tested and comply with the Electromagnetic Interference/Electromagnetic Susceptibility (EMI/EMS) for Class 
B products. Drives are tested in a representative, end-user system by a Korean-recognized lab.

Canada ICES-003

If this model has the ICES-003 Marking it complies with the Canadian Standard Association Standard CAN/CSA-CISPR 22-10, 
Information Technology Equipment - Radio Disturbance Characteristics - Limits and Methods of Measurement.

Australian RCM Compliance Mark

Models displayed with the RCM compliance mark, comply with the mandatory standards as per the Australian Communications and

 

Media Authority (ACMA) Electromagnetic Compatibility (EMC) regulatory arrangement.

2.11.3 FCC verification

These drives are intended to be contained solely within a personal computer or similar enclosure (not attached as an external 
device). As such, each drive is considered to be a subassembly even when it is individually marketed to the customer. As a

 

subassembly, no Federal Communications Commission verification or certification of the device is required.

Seagate has tested this device in enclosures as described above to ensure that the total assembly (enclosure, disk drive, 
motherboard, power supply, etc.) does comply with the limits for a Class B computing device, pursuant to Subpart J, Part 15 of the

 

FCC rules. Operation with noncertified assemblies is likely to result in interference to radio and television reception.

Radio and television interference.

 This equipment generates and uses radio frequency energy and if not installed and used in

 

strict accordance with the manufacturer’s instructions, may cause interference to radio and television reception.

This equipment is designed to provide reasonable protection against such interference in a residential installation. However, there is 
no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or 
television, which can be determined by turning the equipment on and off, users are encouraged to try one or more of the following

 

corrective measures:
• Reorient the receiving antenna.
• Move the device to one side or the other of the radio or TV.
• Move the device farther away from the radio or TV.
• Plug the computer into a different outlet so that the receiver and computer are on different branch outlets.

If necessary, users should consult the dealer or an experienced radio/television technician for additional suggestions. Users may find

 

helpful the following booklet prepared by the Federal Communications Commission: 

How to Identify and Resolve Radio-Television

 

Interference Problems

. This booklet is available from the Superintendent of Documents, U.S. Government Printing Office, Washington, 

DC 20402. Refer to publication number 004-000-00345-4.

2.12

Environmental protection

Seagate designs its products to meet environmental protection requirements worldwide, including regulations restricting certain

 

chemical substances.

2.12.1 European Union Restriction of Hazardous Substances (RoHS) Directive

The European Union Restriction of Hazardous Substances (RoHS) Directive, restricts the presence of chemical substances, including

 

Lead, Cadmium, Mercury, Hexavalent Chromium, PBB and PBDE, in electronic products, effective July 2006. This drive is 
manufactured with components and materials that comply with the RoHS Directive.

̛

ط

ی

߇

ΰ

ח

%

̗

̛̛

ɼࢽࡈ

؏ܞ੼ݦ̛࢕ࢢ

̛̛Е

ɼࢽࡈ

%

̗

ࢷ࢕ળࢶଢ̛̛Ի۰

࣯Ի

ɼࢽ߾۰

یࡈଜЕ

ʨࡶ

ּࢶࡳԻ

ଜֲ

ֻҘ

एࠇ߾۰

یࡈଟ

ܹ

࢑ݡТЬ

Summary of Contents for IRONWOLF PRO ST2000NE0025

Page 1: ...100803998 Rev C November 2016 Standard models ST8000NE0021 ST6000NE0021 ST4000NE0025 ST2000NE0025 v6 SATA Product Manual...

Page 2: ...tting and other functions and thus will not be available for data storage Actual quantities will vary based on various factors including file size file format features and application software Actual...

Page 3: ...0 1 Annualized Failure Rate AFR and Mean Time Between Failures MTBF 18 2 10 2 Seagate Rescue Data Recovery Service Program Terms for Rescue models 18 2 11 Agency certification 20 2 11 1 Safety certifi...

Page 4: ...or information regarding Warranty Support visit http www seagate com support warranty and replacements For information regarding data recovery services visit http www seagate com services software dat...

Page 5: ...Serial ATA host adapter and Serial ATA disk drive in the current system and expect all of the existing applications to work as normal The Serial ATA interface connects each disk drive in a point to po...

Page 6: ...n avg 369 330 Areal density Gb in2 avg 732 651 Spindle speed RPM 7200 Internal data transfer rate Mb s max 2396 2585 Maximum Sustained data transfer rate OD 214 MB s 195 MB s I O data transfer rate MB...

Page 7: ...perating Random psd 2 500 Hz 2Hz 001g2 Hz 4Hz 03g2 Hz 100Hz 03g2 Hz 500Hz 001g2 Hz Drive acoustics sound power bels Idle 2 8 typical 3 0 max 2 2 typical 2 4 max Performance seek 3 2 typical 3 4 max 2...

Page 8: ...0 17 Ready to spindle stop sec max 23 12 Models 8TB 6TB 4TB 2TB Interface Serial ATA SATA Recording method Perpendicular Recording density KBPI Kb in max 2018 1936 Track density KTPI ktracks in avg 36...

Page 9: ...to the S M A R T specification which may increase acoustic and power to operational levels Table 2 DC power requirements 8TB 6 0Gb mode Voltage 5V 12V Watts Regulation 5 Total Avg Idle Current 0 33 0...

Page 10: ...ent 0 418 0 452 7 52 Advanced Idle Current Idle_A 0 422 0 474 7 80 Idle_B 0 327 0 392 6 33 Idle_C 0 335 0 235 4 49 Standby 0 317 0 007 1 66 Peak operating current random read Typical DC 0 439 0 820 12...

Page 11: ...rrent 0 205 0 369 5 45 Advanced Idle Current Idle_A 0 200 0 393 5 70 Idle_B 0 133 0 330 4 63 Idle_C 0 141 0 202 3 13 Standby 0 125 0 001 0 63 Peak operating current random read Typical DC 0 234 0 724...

Page 12: ...e Current 0 288 0 267 4 64 Advanced Idle Current Idle_A 0 287 0 265 4 61 Idle_B 0 172 0 236 3 70 Idle_C 0 181 0 145 2 64 Standby 0 162 0 000 0 82 Peak operating current random read Typical DC 0 311 0...

Page 13: ...line or an equivalent 15 ohm resistive load on the 5V line Using 12V power the drive is expected to operate with a maximum of 120mV peak to peak square wave injected noise at up to 10MHz Using 5V powe...

Page 14: ...omized and enabled using the Extended Power Conditions EPC feature set using the standardized Set Features command interface Immediate host commanded power transitions may be initiated using an EPC Se...

Page 15: ...ssuing the EPC Go to Power Condition subcommand at a rate exceeding the default timers may limit this products reliability and data integrity PowerChoice Supported Extended Power Condition Feature Sub...

Page 16: ...t b Non operating 40 to 158 F 40 to 70 C package ambient with a maximum gradient of 36 F 20 C per hour This specification assumes that the drive is packaged in the shipping container designed by Seaga...

Page 17: ...shock level that the drive can experience without incurring physical damage or degradation in performance when subsequently put into operation is 300 Gs based on a nonrepetitive half sine shock pulse...

Page 18: ...adation in performance when subjected to the radio frequency RF environments defined in the following table Note For seek mode tests the drive is placed in seek mode only The number of seeks per secon...

Page 19: ...bility and to assess whether your data may be recoverable by remote recovery services or whether you will need to send your device to SRS for in lab servicing Rescue General Terms These Rescue General...

Page 20: ...ACT BREACH OF CONTRACT AND TORT AND REGARDLESS OF WHETHER WE HAVE BEEN ADVISED OF THE POSSIBILITY OF LOSS OR DAMAGES UNLESS YOU PROVE THAT SRS CAUSED DAMAGES TO YOU INTENTIONALLY TO THE MAXIMUM EXTENT...

Page 21: ...change your rights under applicable law if such laws do not permit these Program Terms to do so Also the Program and these Program Terms are in addition and unrelated to any rights you may have under...

Page 22: ...ult in interference to radio and television reception Radio and television interference This equipment generates and uses radio frequency energy and if not installed and used in strict accordance with...

Page 23: ...silver copper nickel and gold films used in hard disk drives are especially sensitive to the presence of sulfide chloride and nitrate contaminants Sulfur is found to be the most damaging Materials use...

Page 24: ...n transporting or shipping a drive use only a Seagate approved container Keep the original box Seagate approved containers are easily identified by the Seagate Approved Package label Shipping a drive...

Page 25: ...and blind mateable For installations which require cables users can connect the drive as illustrated in Figure 3 Figure 3 Attaching SATA cabling Each cable is keyed to ensure correct orientation Iron...

Page 26: ...andard documented in SFF 8301 and SFF 8323 found at www sffcommittee org Note The image is for mechanical dimension reference only and may not represent the actual drive 3 750 010 2X 1 625 020 1 432 5...

Page 27: ...10 3 750 010 1 432 019 2 128 010 814 020 2 C L OF DRIVE C L OF CONN 4X 6 32 UNC 2B 3 MIN THREAD DEPTH 1 MAX FASTENER PENETRATION MOUNTING HOLES BOTH SIDES MAX TORQUE 6 IN LBS Y 5 787 MAX 146 99 MM 2X...

Page 28: ...eagate IronWolf Pro v6 Serial ATA Product Manual Rev C 27 Figure 6 Mounting configuration dimensions 2TB Note The image is for mechanical dimension reference only and may not represent the actual driv...

Page 29: ...the ground pins P4 and P12 the pre charge power pins and the other ground pins the signal pins and the rest of the power pins 3 There are three power pins for each voltage One pin from each voltage i...

Page 30: ...eck Power Mode E5H Download Microcode 92H Execute Device Diagnostics 90H Flush Cache E7H Flush Cache Extended EAH Identify Device ECH Idle E3H Idle Immediate E1H NoP 00H Read Buffer E4H Read Buffer DM...

Page 31: ...T Save Attribute Values B0H D3H S M A R T Write Log Sector B0H D6H Standby E2H Standby Immediate E0H Trusted Send 5EH SED drives only Trusted Send DMA 5FH SED drives only Trusted Receive 5CH SED driv...

Page 32: ...revision 8 ASCII character string padded with blanks to end of string x xx 27 46 Drive model number 40 ASCII characters padded with blanks to end of string 47 Bits 7 0 Maximum sectors per interrupt o...

Page 33: ...upport and current mode see note following this table 407FH 89 Security erase time xxxxH 90 Enhanced security erase time xxxxH 92 Master password revision code FFFEH 93 Hardware reset value xxxxH 95 9...

Page 34: ...rial number is supported 3 Media Card Pass Through Command feature set is supported 4 Streaming feature set is supported 5 GPL feature set is supported 6 WRITE DMA FUA EXT and WRITE MULTIPLE FUA EXT c...

Page 35: ...Set transfer mode based on value in Sector Count register Sector Count register values 00H Set PIO mode to default PIO mode 2 01H Set PIO mode to default and disable IORDY PIO mode 2 08H PIO mode 0 0...

Page 36: ...nnecessary drive returns The diagnostic software ships with all new drives and is also available at http www seagate com support downloads seatools This drive is shipped with S M A R T features disabl...

Page 37: ...ted States 408 658 1000 ASIA PACIFIC Seagate Singapore International Headquarters Pte Ltd 7000 Ang Mo Kio Avenue 5 Singapore 569877 65 6485 3888 EUROPE MIDDLE EAST AND AFRICA Seagate Technology SAS 16...

Reviews: