Acoustics

Drive acoustics are measured as overall A-weighted acoustic sound power levels (no pure tones). All measurements are consistent 
with ISO document 7779. Sound power measurements are taken under essentially free-field conditions over a reflecting plane. For all 
tests, the drive is oriented with the cover facing upward.

)

* During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and power to operational levels

.

2.8

Test for Prominent Discrete Tones (PDTs)

Seagate follows the ECMA-74 standards for measurement and identification of PDTs. An exception to this process is the use of the

 

absolute threshold of hearing. Seagate uses this threshold curve (originated in ISO 389-7) to discern tone audibility and to compensate

 

for the inaudible components of sound prior to computation of tone ratios according to Annex D of the ECMA-74 standards.

2.9

Electromagnetic immunity

When properly installed in a representative host system, the drive operates without errors or degradation in performance when

 

subjected to the radio frequency (RF) environments defined in the following table:

Note

For seek mode tests, the drive is placed in seek mode only.

 

The number of seeks per second is defined by the following equation:

(Number of seeks per second = 0.4 / (average l average access time

Table 3

Fluid Dynamic Bearing (FDB) motor acoustics

Idle*

Performance seek

All models

2.8 bels (typ)

 

3.0 bels (max)

3.2 bels (typ)

 

3.4 bels (max)

Table 4

Radio frequency environments

Test

Description

Performance level

Reference standard

Electrostatic discharge

Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV

B

EN 61000-4-2: 95

Radiated RF immunity

80 to 1000 MHz, 3 V/m, 

 

80% AM with 1 kHz sine

 

900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz

A

EN 61000-4-3: 96

 

ENV 50204: 95

Electrical fast transient

± 1 kV on AC mains, ± 0.5 kV on external I/O

B

EN 61000-4-4: 95

Surge immunity

± 1 kV differential, ± 2 kV common, AC mains

B

EN 61000-4-5: 95

Conducted RF immunity

150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz sine

A

EN 61000-4-6: 97

Voltage dips, interrupts

0% open, 5 seconds

 

0% short, 5 seconds

 

40%, 0.10 seconds

 

70%, 0.01 seconds

C

 

C

 

C

 

B

EN 61000-4-11: 94

Summary of Contents for IronWolf Pro ST10000NE000

Page 1: ...200403800 Rev B March 2021 Standard 512E model ST10000NE000 SATA Product Manual...

Page 2: ...ytes and one terabyte or TB equals one trillion bytes Your computer s operating system may use a different standard of measurement and report a lower capacity In addition some of the listed capacity i...

Page 3: ...onducted noise 10 2 5 3 Voltage tolerance 10 2 5 4 Extended Power Conditions PowerChoice 11 2 6 Environmental limits 13 2 6 1 Temperature 13 2 6 2 Humidity 13 2 6 3 Shock and Vibration 14 2 7 Acoustic...

Page 4: ...onfiguring the drive 20 3 3 Serial ATA cables and connectors 20 3 4 Drive mounting 21 3 4 1 Mechanical specifications 21 4 0 Serial ATA SATA interface 22 4 1 Hot Plug compatibility 22 4 2 Serial ATA d...

Page 5: ...eagate com support downloads For information regarding online support and services visit www seagate com contacts For information regarding Warranty Support visit www seagate com support warranty and...

Page 6: ...install a Serial ATA host adapter and Serial ATA disk drive in the current system and expect all of the existing applications to work as normal The Serial ATA interface connects each disk drive in a...

Page 7: ...2499 Track density KTPI ktracks in 0 skew 487 Areal density Gb in2 0 skew mid disk 1215 Spindle speed RPM 7200 Internal data transfer rate Mb s max 2169 Sustained data transfer rate OD MiB s max 229 2...

Page 8: ...f drive idle some offline activity may occur according to the SMART specification which may increase acoustic and power to operational levels Performance seek 3 2 typical 3 4 max Nonrecoverable read e...

Page 9: ...tdown a Flush Cache Standby or Standby Immediate command must be completed before removal of interface power An unexpected power loss event spin up at cold or hot temperature extremes may cause the dr...

Page 10: ...sted under nominal conditions using 5 0V and 12 0V input voltage at 25 C ambient temperature Table 2 DC Power Requirements 5 disk models Power Dissipation Avg 25 C Watts Avg 5V typical Amps Avg 12V ty...

Page 11: ...e or an equivalent 15 ohm resistive load on the 5V line Using 12V power the drive is expected to operate with a maximum of 120mV peak to peak square wave injected noise at up to 10MHz Using 5V power t...

Page 12: ...ded Power Conditions EPC feature set using the standardized Set Features command interface Immediate host commanded power transitions may be initiated using an EPC Set Features Go to Power Condition s...

Page 13: ...r specified defaults or issuing the EPC Go to Power Condition subcommand at a rate exceeding the default timers may limit this products reliability and data integrity PowerChoice Supported Extended Po...

Page 14: ...ng 40 to 158 F 40 to 70 C package ambient with a maximum gradient of 36 F 20 C per hour This specification assumes that the drive is packaged in the shipping container designed by Seagate for use with...

Page 15: ...erable errors after being subjected to shock pulses not exceeding 300g at a maximum duration of 2ms 2 6 3 2 Vibration a Linear Random Operating Vibration The drive will operate without non recoverable...

Page 16: ...When properly installed in a representative host system the drive operates without errors or degradation in performance when subjected to the radio frequency RF environments defined in the following...

Page 17: ...duplicate every potential application environment Users should use caution exposing any electronic components to uncontrolled chemical pollutants and corrosive chemicals as electronic drive component...

Page 18: ...1 800 468 3472 Users can also determine remaining warranty using the Seagate web site www seagate com The drive serial number is required to determine remaining warranty information Shipping When tran...

Page 19: ...eproduced on a backup medium c receive the recovered data and d agree to these Program Terms You will defend and indemnify us including our directors officers employees agents delegates and contractor...

Page 20: ...The parties will attempt to resolve any dispute arising out of or related to these Program Terms or any data recovery services requested or attempted hereunder through good faith negotiation To the e...

Page 21: ...r end of the SATA signal cable can be attached to the drive or host For direct backplane connection the drive connectors are inserted directly into the host receptacle The drive and the host receptacl...

Page 22: ...ng configuration dimensions See Section 3 4 Drive mounting Figure 4 Mounting configuration dimensions 5 disk models Weight 10TB models 1 587 lb 720g Note These dimensions conform to the Small Form Fac...

Page 23: ...the ground pins P4 and P12 the pre charge power pins and the other ground pins the signal pins and the rest of the power pins 3 There are three power pins for each voltage One pin from each voltage is...

Page 24: ...k Power Mode E5H Download Microcode 92H Execute Device Diagnostics 90H Flush Cache E7H Flush Cache Extended EAH Identify Device ECH Idle E3H Idle Immediate E1H NoP 00H Read Buffer E4H Read Buffer DMA...

Page 25: ...T Save Attribute Values B0H D3H S M A R T Write Log Sector B0H D6H Standby E2H Standby Immediate E0H Trusted Send 5EH SED drives only Trusted Send DMA 5FH SED drives only Trusted Receive 5CH SED drive...

Page 26: ...aracters padded with blanks to end of string Reported in ASCII 47 Bits 7 0 Maximum sectors per interrupt on Read multiple and Write multiple 16 8010H 48 Trusted computing feature set options 4000H 49...

Page 27: ...x0000 2710H 100 103 Total number of user addressable LBA sectors available see Section 2 2 for related infor mation These words are required for drives that support the 48 bit addressing feature Maxim...

Page 28: ...is supported 5 GPL feature set is supported 6 WRITE DMA FUA EXT and WRITE MULTIPLE FUA EXT commands are supported 7 WRITE DMA QUEUED FUA EXT command is supported 8 64 bit World Wide Name is supported...

Page 29: ...et transfer mode based on value in Sector Count register Sector Count register values 00H Set PIO mode to default PIO mode 2 01H Set PIO mode to default and disable IORDY PIO mode 2 08H PIO mode 0 09H...

Page 30: ...unnecessary drive returns The diagnostic software ships with all new drives and is also available at www seagate com support downloads seatools This drive is shipped with S M A R T features disabled U...

Page 31: ...Seagate Technology LLC AMERICAS Seagate Technology LLC 47488 Kato Road Fremont California 94538 United States 510 661 1000 Publication Number 200403800 Rev B March 2021...

Reviews: