Elite 47 Product Manual, Rev. A
27
6.4.4.2
Vibration
a. Operating—normal
The drive, as installed for normal operation, complies with the complete specified performance while sub-
jected to continuous vibration not exceeding:
5-300 Hz @ 0.5 g (X, Y, or Z axis)
b. Operating—abnormal
Equipment, as installed for normal operation, does not incur physical damage while subjected to periodic
vibration not exceeding:
5-300 Hz @ 0.75 g (X, Y, or Z axis)
15 minutes of duration at major resonant frequency
Vibration occurring at these levels may degrade operational performance during the abnormal vibration
period. Specified operational performance will continue when normal operating vibration levels are
resumed. This assumes system recovery routines are available.
c. Non-operating
The limits of non-operating vibration apply to all conditions of handling and transportation. This includes
both isolated drives and integrated drives.
The drive does not incur physical damage or degraded performance as a result of continuous vibration not
exceeding:
5-22 Hz @ 0.040 inches (1.02 mm) displacement
22-400 Hz @ 1.00 g
Vibration may be applied in the X, Y, or Z axis.
6.4.5
Air cleanliness
The drive is designed to operate in a typical office environment with minimal environmental control.
6.4.6
Acoustics
Sound power during idle shall be 4.6 bels typical when measured to ISO 7779 specification. No prominent
tones are allowed.
6.4.7
Electromagnetic susceptibility
See Section 2.1.
6.5
Mechanical specifications
The following nominal dimensions are exclusive of the decorative front panel accessory. However, dimensions
of the front panel are shown in the figure below. Refer to Figure 6 for detailed mounting configuration dimen-
sions. See Section 8.4, “Drive mounting.”
Typical
Maximum
Height:
3.25 in (82.6 mm)
3.268 in (83.0 mm)
Width:
5.75 in (146.1 mm)
5.76 in (146.3 mm)
Depth:
8.0 in (203.0 mm)
8.01 in (203.5 mm)
Weight: