Environmental limits
Temperature and humidity values experienced by the drive must be such that condensation does not occur on
any drive part. Altitude and atmospheric pressure specifications are referenced to a standard day at 58.7°F
(14.8°C). Maximum wet bulb temperature is 82°F (28°C).
6.4.1
Temperature
a. Operating
With cooling designed to maintain the case temperatures of Table 4, the drive meets all specifications over
a 41°F to 131°F (5°C to 55°C) drive ambient temperature range with a maximum temperature gradient of
36°F (20°C) per hour. The enclosure for the drive should be designed such that the temperatures at the
locations specified in Table 4 are not exceeded. Air flow may be needed to achieve these temperature val-
ues (see Section 8.3 and 8.3.1). Operation at case temperatures above these values may adversely affect
the drives ability to meet specifications.
The MTBF specification for the drive is based on operating in an environment that ensures that the case
temperatures specified in Table 4 are not exceeded. Occasional excursions to drive ambient temperatures
of 131°F (50°C) or 41°F (5°C) may occur without impact to specified MTBF. Air flow may be needed to
achieve these temperatures (see Section 8.3.1). Continual or sustained operation at case temperatures
above these values may degrade MTBF.
To confirm that the required cooling for the electronics and HDA is provided, place the drive in its final
mechanical configuration, perform random write/read operations. After the temperatures stabilize, measure
the case temperature of the components listed in Table 4 (see note [2]).
The maximum allowable HDA case temperature is 65°C. Operation of the drive at the maximum case tem-
perature is intended for short time periods only. Continuous operation at the elevated temperatures will
reduce product reliability.
Table 4:
PCBA and HDA temperatures
Notes.
[1]
Section 8.3.1 describes the air-flow patterns used when generating the 1,200,000 hours MTBF guide-
lines in column 2. Air flow was opposite that shown in Section 8.3.1. Local air velocity was 0.92 m/sec
(180 lfpm). Inlet air temperature to the drive was 77°F (25°C), plus 9°F (5°C) temperature rise in the
test enclosure (86°F/30°C ambient local to the drive).
[2]
Measure HDA temp at point labeled “HDA” on Figure 11.
[3]
PCB mounted integrated circuit case.
Items in
Figure 11
Maximum allowable
case temperature (
°
C)
operating
Maximum allowable
case [3] temperatures (°C)
to meet MTBF spec.
HDA [2]
65
50
U5
103.3
83.3
U14
80.8
60.8
U11
63.9
43.9
U20
79.6
59.6
Summary of Contents for Cheetah X15
Page 1: ... Cheetah X15 Disc Drive ST318451LW LC ST39251LC Product Manual Volume 1 ...
Page 2: ......
Page 3: ... Cheetah X15 Disc Drive ST318451LW LC ST39251LC Product Manual Volume 1 ...
Page 6: ......
Page 10: ......
Page 12: ...2 Cheetah X15 Product Manual Rev C ...
Page 16: ...6 Cheetah X15 Product Manual Rev C Figure 2 Cheetah X15 family drive exploded view ...
Page 30: ...20 Cheetah X15 Product Manual Rev C ...
Page 40: ...30 Cheetah X15 Product Manual Rev C Figure 12 Recommended mounting Z Y X Z Y X ...
Page 44: ...34 Cheetah X15 Product Manual Rev C ...
Page 54: ...44 Cheetah X15 Product Manual Rev C ...
Page 84: ...74 Cheetah X15 Product Manual Rev C ...
Page 90: ......
Page 91: ......