20
Cheetah 73LP FC Product Manual, Rev. D
4.
Parameters, other than spindle start, are measured after a 10-minute warm up.
5.
No terminator power.
6.2.1
Conducted noise immunity
Noise is specified as a periodic and random distribution of frequencies covering a band from DC to 10 MHz.
Maximum allowed noise values given below are peak-to-peak measurements and apply at the drive power
connector.
6.2.2
Power sequencing
The drive does not require power sequencing. The drive protects against inadvertent writing during power-up
and down.
6.2.3
Current profiles
Figure 3 identifies the drive +12V current profile. The current during the various times is as shown:
T0
Power is applied to the drive.
T1
Controller self-tests are performed.
T2
Spindle begins to accelerate under current limiting after performing internal diagnostics.
T3
Spindle is up to speed and the Head-Arm restraint is unlocked.
Note:
All times and currents are typical. See Table 1 for maximum current requirements.
Figure 3.
Typical ST373405FC drive +12V current profile
+5V
+12V
0 to 100 kHz
150mV
150mV
100 kHz to 10 MHz
100mV
100mV
0
2
4
6
8
10
12
14
16
0.0
1.0
2.0
A
3.0
Seconds
Envelope of waveform
+12 Volt Current during spindle start – Typical Amperes
Average value of waveform
T0
T1 T2
T3 T4
Summary of Contents for Cheetah 73LP FC ST336605FC
Page 1: ... Cheetah 73LP FC Disc Drive ST373405FC FCV ST336605FC FCV Product Manual Volume 1 ...
Page 2: ......
Page 3: ... Cheetah 73LP FC Disc Drive ST373405FC FCV ST336605FC FCV Product Manual Volume 1 ...
Page 6: ......
Page 10: ......
Page 12: ...2 Cheetah 73LP FC Product Manual Rev D ...
Page 18: ...8 Cheetah 73LP FC Product Manual Rev D ...
Page 70: ...60 Cheetah 73LP FC Product Manual Rev D ...
Page 74: ...64 Cheetah 73LP FC Product Manual Rev D ...
Page 81: ......