10
Barracuda ATA III Family Product Manual, Rev. B
1.7.2 Conducted noise
Input noise ripple is measured at the host system power supply across
an equivalent 80-ohm resistive load on the +12 volt line or an equivalent
15-ohm resistive load on the +5 volt line.
•
Using 12-volt power, the drive is expected to operate with a maximum
of 120 mV peak-to-peak square-wave injected noise at up to 10 MHz.
•
Using 5-volt power, the drive is expected to operate with a maximum
of 100 mV peak-to-peak square-wave injected noise at up to 10 MHz.
Note. Equivalent resistance is calculated by dividing the nominal volt-
age by the typical RMS read/write current.
1.7.3 Voltage tolerance
Voltage tolerance (including noise):
1.7.4 Power-management modes
The drive provides programmable power management to provide great-
er energy efficiency. In most systems, you can control power manage-
ment through the system setup program. The drive features the following
power-management modes:
•
Active mode
The drive is in Active mode during the read/write and seek operations.
•
Idle mode
The buffer remains enabled, and the drive accepts all commands and
returns to Active mode any time disc access is necessary.
5V
±
5% 0.7
amps
max
12V
±
10%
2.2 amps max
Power Modes
Heads
Spindle
Buffer
Active
Tracking
Rotating
Enabled
Idle
Tracking
Rotating
Enabled
Standby
Parked Stopped
Enabled
Sleep
Parked
Stopped
Disabled