SET
DESCRIPTION
DEFAULT
SET
VALUE
57
WORKING CURRENT 1
…... Ampere
Shows the absorbed current during Motor 1 working
58
WORKING CURRENT 2
…... Ampere
Shows the absorbed current during Motor 2 working
59
OPENING SLOWDOWN 1
0 50
From 0% to 50% of the stroke
(0% = slowdown excluded)
30
60
CLOSING SLOWDOWN 1
0 50
From 0% to 50% of the stroke
(0% = slowdown excluded)
30
61
OPENING SLOWDOWN 2
0 50
From 0% to 50% of the stroke
(0% = slowdown excluded)
30
62
CLOSING SLOWDOWN 2
0 50
From 0% to 50% of the stroke
(0% = slowdown excluded)
30
63
DECELERATION
0 %
100%
Adjust the passage between normal speed and
slowdown speed
It depends
on motor
64
ACCELERATION
0,1 s
5 s
Acceleration ramp
Adjusts the motor start
It depends
on motor
Off
Desactivates the leaves anti-overlapping control,
allowing separate control of the two leaves
On
Activates the leaves anti-overlapping control
70
OPENING POSITION
RECOVERY
0 20 seconds
(only if 32-Encoder is OFF)
Retrieves the inertia of the motor in opening after Stop
or reversing
1s
71
CLOSING POSITION
RECOVERY
0 20 seconds
(only if 32-Encoder is OFF)
Retrieves the inertia of the motor in closing after Stop
or reversing
1s
72
OPENING TOLERANCE
MOTOR 1
0% 100%
Adjusts the tolerance between stop and obstacle on
Motor 1 in opening
20%
73
CLOSING TOLERANCE
MOTOR 1
0% 100%
Adjust the tolerance between stop and obstacle on
Motor 1 in closing
20%
74
OPENING TOLERANCE
MOTOR 2
0% 100%
Adjusts the tolerance between stop and obstacle on
Motor 2 in opening
20%
75
CLOSING TOLERANCE
MOTOR 2
0% 100%
Adjust the tolerance between stop and obstacle on
Motor 2 in closing
20%
Time
Pushing Off - 3 sec
Stroke
Before opening, the motor starts in closing for the set
time, in order to simplify the lock release
Repeat
Lock Off – On
Release
If On, the lock will release both before and after the
pushing stroke
End
77
LOCK TIME
Off 5
Sets the lock release time from 0 to 5 seconds
3
Only opening
Active only before opening
Only closing
Active only before cloning
Opening and closing
Active before opening and closing
Only opening
Only closing
Opening and closing
Off
79
ANTI INTRUSION
If you force the gate manually, the control unit starts
the motor to restore the status of the gate before
forcing (only with limit switch)
Off
76
PUSHING STROKE
Off
78
LOCK
Only
opening
For menu from 65 to 68 see menu 32-Encoder = Off (They are visible even with 32-Encoder set ON)
69
ANTI OVERLAP
Off
MENU SP