SET
DESCRIPTION
DEFAULT
SET
VALUE
32
ENCODER
Off
ON enables the Encoder;
OFF shows working times learnt
Off
65
OPENING TIME M1
xxx.s
66
CLOSING TIME M1
xxx.s
67
OPENING TIME M2
xxx.s
68
CLOSING TIME M2
xxx.s
10% (Fast intervention)
99% (Slow intervention)
Adjusts the Encoder or Potentiometer intervention
time on Motor 1 in opening
Off (Intervention excluded)
Disabled
10% (Fast intervention)
99% (Slow intervention)
Adjusts the Encoder or Potentiometer intervention
time on Motor 1 in closing
Off (Intervention excluded)
Disabled
10% (Fast intervention)
99% (Slow intervention)
Adjusts the Encoder or Potentiometer intervention
time on Motor 2 in opening
Off (Intervention excluded)
Disabled
10% (Fast intervention)
99% (Slow intervention)
Adjusts the Encoder or Potentiometer intervention
time on Motor 2 in closing
Off (Intervention excluded)
Disabled
10% (Fast intervention)
99% (Slow intervention)
Adjusts the amperometric sensitivity in slowdown.
Active only if the motors are electromechanical
Off
With potentiometer
In case of linear potentiometer, this parameter allows
to set the inversion time in slow-down from 0 to 5
seconds (= 99%)
30%
38
POTENTIOMETER
THRESHOLD OPENING 1
39
POTENTIOMETER
THRESHOLD CLOSING 1
40
POTENTIOMETER
THRESHOLD OPENING 2
41
POTENTIOMETER
THRESHOLD CLOSING 2
42
POTENTIOMETER
SLOWDOWN THRESHOLD
OPENING 1
43
POTENTIOMETER
SLOWDOWN THRESHOLD
CLOSING 1
44
POTENTIOMETER
SLOWDOWN THRESHOLD
OPENING 2
45
POTENTIOMETER
SLOWDOWN THRESHOLD
CLOSING2
Total
In case of obstacle or edge it totally reverses the
movement during the closing. If actived, the automatic
reclosing will be attempted 5 times
Partial
It partially reverses the direction (of about 30 cm) in
case of obstacle or edge or potentiometer, then it
stops
For menu 47 and 50 see menu 32-Encoder = On
For menu from 51 to 56 see menu 32-Encoder = Potentiometer
CLOSING SENSITIVITY
MOTOR 1
Off
35
OPENING SENSITIVITY
MOTOR 2
Off
46
CLOSING INVERSION
Total
1 1000
(only if the
Menu-32 Encoder
is set on "Potentiometer")
Adjusts
the
threshold
of
the
potentiometer
intervention.
The
parameter
self-determines
in
learning but can also be adjusted later. The lower the
value, the slower will be the response of the
potentiometer. The parameter can be set as maximum
threshold at the value read on the DEBUG VPI, VP2
menu
- - - -
15
1 100
(only if the
Menu-32 Encoder
is set on "Potentiometer")
Adjusts the threshold of the potentiometer in
slowdown. By default this value is set on 15 and can be
increased manually up to the maximum value read on
the DEBUG VPI, VP2 Menu
34
Indicates the working times self-learning in opening and closing (Motor
1). With UP or DOWN it is possible to increase or reduce the working
times
Indicates the working times self-learning in opening and closing (Motor
2). With UP or DOWN it is possible to increase or reduce the working
times
33
OPENING SENSITIVITY
MOTOR 1
Off
MENU SP
36
CLOSING SENSITIVITY
MOTOR 2
Off
37
SLOWDOWN SENSITIVITY
MOTOR
26