Fig. 15
55 mm min.
Fig. 16
Fig. 17
Fig. 18
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
40
20
Fig. 19
Fig. 20
Fig. 21
ENGLISH
16
67411740
4.3.
Be careful not to place the leaf outside the axis (Fig. 16
and 17) and make sure that the shaft corresponds to the
rotation axis of the jack.
5 . H Y D R A U L I C U N I T B O X W A L L
INSTALLATION (Fig.19)
5.1.
Connect the hydraulic tubes with the hydraulic unit and the
jack (Fig.21, Fig.22, Fig.23).
After having installed the box, the gate and the operator, try to
slowly move the gate by hand to make sure that there are no
irregular frictions and that the movement is uniform for the whole
range.
Notice:
To do this last operation, release the operator as
described in the related paragraph.
Hydraulic
tubes
inlet
Cable
inlet
REV 01 - 03/2015