START - STOP - PEDESTRIAN START - ANTENNA -

PHOTOCELL

START (N.O.) The

An impulse given to this contact opens and closes the automation depending onthe selected logic it can be given by a key switch, a keypad, 
etc.   To connect the other devices refer to the related instructions leaflets. (ie. loop detectors and proximity switches).

Note1

: In DEAD MAN logic it is necessary to keep pressed the Start for the opening   of the automation.

Note2

 START is connected between the clamps 2 and 3 of the CN 1 terminal.

In 2 BUTTONS logic this button performs the opening.

STOP (N.C.) The STOP is connected between the clamps   2 and 5 of the CN1 terminal .

The pressure on this button immediately stops the motor in any condition/position.   A   start command is needed to re-start the movement.
After a stop the motor always re-starts in closing. 

Photocell 1 and Photocell 2 Connections 

  

+ = 24V       (Accessories) max 750mA        COM = 0V     PH1 = Photocell contact 1     
PH2 = Photocell contact 2

Note

: For the autotest connect the TX to the AUX clamp and activate the Autotest function.

The standard setting of the photocell 1 is FOTO CLOSE and the one of the photocell 2 is   FOTO 
OPEN.           The photocell 2 can be set also as TIMER   (see TIMER function).

Note3: 

On the 

fototest

 menu you can also activate the self-test even on the single photocell.

Can be activated through on-board display or through the Jolly programmer. In both cases it’s a N.O. contact which provoques 
the opening of the automation keeping it open until it is activated.   When it’s released, the gate attends the set pausing time 
and executes the reclosing. The TIMER command can be activated on the inputs FOTO2, START PEDESTRIAN.

Note1

: When activated on the pedestrian entry, the pedestrian will be disabled also on the radio transmitter.

Note2

: In case of intervention of a security device during the timer (Stop, Ammeter, Edge), to restore the movement it will be 

necessary to give a start impulse.

Note3

: In case of no power supply with open gate and active Timer the control unit   will restore its use, otherwise if during   

restore of the power supply   the   TIMER is not activated it will be necessary to give a start impulse for the reclosing. 

TIMER

A

nte

nn

a

C

om

m

on

S

ta

rt

S

ta

rt 

pe

d.

S

to

p

C

om

m

on

P

ho

to

ce

ll 1

CN1

1

2 3 4 5

6 7 8

P

ho

to

ce

ll 2

RX1

RX2

TX1

TX2

CN1

9 10 11 12 13

C

om

m

on

24V

 (A

cce

sso

ries

)

PEDESTRIAN START (N.O.) The pedestrian start can be connected 
between the clamps 2 and 4 of the CN1 terminal .

This input allows a partial opening the opening space can be set through 
the on-board display   or through the JOLLY device. 

Note1

: The contact for partial opening is a N.O. Contact (Normally   open).

Note2

:In 2 BUTTONS logic it is necessary to keep pressed the Start Ped. 

to re-close the automation.

Note3

: In dead man logic this button executes the re-closing if you keep it 

pressed.

Note4

: When closed during pause, the gate will reclose only after this 

input has been reopened.

TIMER activation

: This input can be transformed into TIMER (See 

TIMER).

Options AUX 24V       max 200mA can be set with on-board 
Display or with Jolly device.        

Through the Jolly programmer it is possible to chose when having 
tension on the AUX output. The options are: always, only during 
opening, only during cycle, only before opening or only during 
pause, 

fototest 

and

 in (y(le and fototest.

When using control units with batteries and / or solar panels, we 
recommend connecting the accessories which are not used when 
operator stands still (e.g. photocells) to a AUX output, setting the 
option “

in (y(le

”. With this setting you can save energy by 

lowering power consumption in stand-by, increasing the autonomy 
of the system.

               OPTIONS ON FOTO1 and  FOTO2 adjustable on on- board display or with 
JOLLY terminal.
FOTO CLOSE activation (

(losing

)

: if occupied, reverses the movement in closing, during 

pause it prevent the closing.

Activation repeat pause (

pavse RELOAD

)

: If occupied, during pause it recharges the timer 

of pause. In closing it reverses the movement.

FOTO OPEN activation (

oPEning

): 

If activated the photocell blocks the movement as long 

as it’s busy,

 

when released   the opening continues.

FOTO PARK activation (

stop and (lose

: in opening it is not active; in pause are activated 

it commands the closing when released, otherwise it’s not active; in closing it stops the 
movement as long as it is busy, when released the closing continues.   

FOTO STOP activation (

STOP

)

: When activated before the opening the photocell blocks the 

automation as long as it is busy, during the opening it will be ignored. In closing the 
intervention of the photocell causes the reopening. 

Activation PHOTO CLOSE IMMEDIATELY (

(lose

)

: The photocell stops the gate as long 

as it is occupied in both opening and closing, when released it gives a closing command 
(Closing one second after release of the photocell ).

delay pause ti   e 

activation

If the photocell is occupied during opening, pause or 

closing, the gate reopens completely and closes without observing the pause time.

u

67411535

REV 07 - 06/2014

15

Summary of Contents for USER 1 24V DG R1

Page 1: ...ES AND BARRIERS 67411535 REV 07 06 2014 International registered trademark n 2 777 971 SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 USA Tel Toll free 1 305 594 1151 1 305 594 7325 800 689 4716 web site www sea usa com e mail sales sea usa com ...

Page 2: ...xternal controls and devices serving as required protection against entrapment shall be provided with the operator when such controls are shipped with the operator Instructions regarding intended installation of the gate operator shall be supplied as part of the installation instructions or as a separate document The following instructions or the equivalent shall be supplied where applicable a Ins...

Page 3: ...al landscaping or similar obstruction A wireless contact sensor shall function under the intended end use conditions 6 One or more contact sensors shall be located on the inside and outside leading edge of a swing gate Additionally if the bottom edge of a swing gate is greater than 6 inches 152 mm above the ground at any point in its arc of travel one or more contact sensors shall be located on th...

Page 4: ...fet R1 Motors command relay R2 Motors command relay PR1 Rectifier jumper F1 Fuse 10 AT CN8 F1 CN1 CNA CN3 CN5 CNP CN6 RL2 RL1 CN2 CN4 CN7 UP DOWN OK RD3 RD1 PR1 DISPLAY 1 2 3 4 5 6 7 8 9 10 11 12 13 1 EXP POWER FUSE BATTERY S MOTOR LIGHT MASTER SLAVE PROG RADIO MODULE JOLLY LIMIT SWITCH 156 mm 6 inches 100 mm 4 inches RECEIVER RX JOLLY JOLLY2 TECHNICALSPECIFICATIONS Control unit power supply Absor...

Page 5: ...sion 34 Flash Photocell 2 1 2 3 4 5 6 7 8 9 10 11 12 13 CN1 ANT COM START PEDST STOP COM PH1 PH2 EDGE AUX COM 24V FL Start Stop Common Antenna START Ped Common Photocell 1 Common AUX 24V 200 mA max 24V 750 mA max Accessori Safety edge Flash Photocell 2 Optional WARNING The control unit is designed with the automatic detection of not used N C inputs photocells Stop and Limit switch except the SAFET...

Page 6: ...to main menu With UP or DOWN choose a delay for automatic closing To confirm and return to main menu Skip this step if you wna tto work in half automatic logic With UP or DOWN Choose ON To confirm and return to main menu With UP or DOWN choose ON to start times learning At the end of the selflearning the control unit returns automatically to the main menu With UP or DOWN Choose ON to start test To...

Page 7: ... nt 4 eters U Spr nt 5 eters U Stor 5 eters U U Stor 6 eters U U Stor 7 5 eters U U satvrn Er vry 800 U Uergl 5 eters U Uergl 4 eters U Uergl 3 eters U Sl d ng Sl d ng U 4 reuerse otor 5 log Avto at U open stop lose stop open 2 bvttons safety Dead an U open stop lose open 6 paVse t e U Pedestrian Start Delete single transmitter Sliding Synchronized right motor Synchronized left motor Automatic Ste...

Page 8: ...osing reverses the movement STEPBYSTEPTYPE 1 LOGIC The start impulse follows the OPEN STOP CLOSE STOP OPEN logic STEPBYSTEPTYPE 2 LOGIC The start impulse follows the OPEN STOP CLOSE OPEN logic DEAD MAN LOGIC The gate opens as long as the START button of opening is pressed releasing it the gate stops The gate closes as long as the button connected to the PEDESTRIAN START is pressed releasing it the...

Page 9: ...al menu move on one of the menu and press the buttons at the same time for 5 s For exiting the special menu move on one of the menu and press the buttons at the same time for 5 s Description Set Value Setting from 30 to 100 Setting from 30 to 100 Setting from 10 to 100 Setting from 10 to 100 Disabled Disabled Setting from 5 to 100 Setting from 5 to 100 Pre flashing active only before closing Contr...

Page 10: ... pausing time Photocell active before opening The photocell stops in closing and closes when released Photocell active in closing Photocell active in opening and closing The photocell gives a command to close during opening pause and closing The photocell charging the pausing time Photocell active before opening The photocell stops in closing and closes when released Normal N C contact If the phot...

Page 11: ... Adjusts the amperometric tolerance in relation to the detected stop in closing Adjust the amperometric tolerance in relation to the detected stop in opening Disabled PXOTO1 2 The flashing light remains ON with active timer and open gate The flashing light remains OFF with the active timer and open gate Adjustable from 10 to 99 Increasing the value the reversing on obstacles will be delayed 21 24u...

Page 12: ...rease or decrease the number press OK to confirm it and you will pass automatically to the entering of the next number Pressing OK after the last entered number the word SvRE appears confirm the activation of the PASSWORD and the message Ok appears pressing UP or DOWN instead you can cancel the operation and NO OPERATION will appear on the display Once entered the PASSWORD it will be definitively ...

Page 13: ... must be N O If activating the related command on the display the item SET lights up the input will be working If SET is always on check the wirings Safety edge test Photocell 1 test Photocell 2 test The contact must be N C If activating the related command on the display the item SET lights up the input will be working If SET is always on make sure that the contact is a N C one The contact must b...

Page 14: ...rmine the type of the remaining radio transmitters If the receiver is a Rolling Code press twice the button of the radio transmitter that you want to program to memorize the first TX Notes Enter radio transmitters learning only when the working cycle stops and the gate is closed You can store max 2 of the available 4 functions If the control unit receives a code which was already associated to ano...

Page 15: ...an start can be connected between the clamps 2 and 4 of the CN1 terminal This input allows a partial opening the opening space can be set through the on board display or through the JOLLYdevice Note1 The contact for partial opening is a N O Contact Normally open Note2 In 2 BUTTONS logic it is necessary to keep pressed the Start Ped to re close the automation Note3 In dead man logic this button exe...

Page 16: ...switch can be connected through the special LIMIT SWITCH connector on the control unit The control unit can administrate mechanical inductive and magnetic limit switches Only on some special applications il will not be necessary to connect the limit switches The control unit will automatically realize if limit switches are present or not 1 Through the on board display or through the JOLLY programm...

Page 17: ...alarm will show on the on board dispaly or on the JOLLYprogrammer SECURITY EDGE AND WARNING LAMP OR BUZZER EXTERNAL RECEIVER Example Connection of a radio receiver For the connection of the receiver refer to the relative instructions manual Common Common Start ped Flashing Lamp 24V 15W Warning lamp or Buzzer The flashing lamp or buzzer can be connected between the clamps 24V Accessories and FL of ...

Page 18: ...t Note 1 The master and slave settings on the control unit are present in the special menu selecting ASter slaue Note 2 All these operations can also be managed through the JOLLY programmer Note 3 On the SLAVE it is possible to set the following functions only torque speed motor type slowdown speed acceleration deceleration position recovery AUX and motor inversion All other parameters will be set...

Page 19: ...charge 200mA BAT GND PSOL BAT 28V GND CN1 S GND GND Solar Panel Batteries 12V 12V charge 360mA charge 800mA Cod 23101105 800 360 200 12 or 16 7 2 19 International registered trademark n 2 777 971 USER 1 24V DG R1 CONNECTION OF BATTERIES TO BATTERY CHARGER CARD Specifications of optional batteries 24V Pb 1 2Ah min 67411535 REV 07 06 2014 ...

Page 20: ...TROUBLE SHOOTING Advises Make sure all Safeties are turned ON Problem Found Possibile Cause Solutions Motor doesn t respond to any START impulse Gate doesn t move while the motor is running Gate doesn t reach the complete Open Closed position The gate opens but doesn t close The gate doesn t close automatically a Check the connected N C contacts b Burnt fuse a The motor is in the released position...

Page 21: ... the original buyer only Hydraulic and oil bath motors 36 months warranty from the date of invoice on manufacturing assembling and workmanship defects Electro mechanic motors and electronic control systems 24 months warranty from the date of invoice on manufacturing assembling and workmanship defects Lepus and Full Tank Standard model 60 months warranty from the date of invoice on manufacturing as...

Page 22: ......

Page 23: ......

Page 24: ...c 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 USA Tel Toll free 1 305 594 1151 1 305 594 7325 800 689 4716 web site www sea usa com e mail sales sea usa com International registered trademark n 2 777 971 ...

Reviews: