SET
DESCRIPTION
MODEL
DEFAULT
NOTE
Off
Disabled
Emergency
In case of power failure and with batteries connected
and charged, the gate opens completely and remains
open until the power is restored
Last opening
In case of power failure, as soon as the battery charge
drops below 22V, the gate opens one last time and
remains open until the power is restored
Last closing
In case of power failure, as soon as the battery charge
drops below 22V, the gate closes one last time and
remains closed until the power is restored
115
DECELERATION
RAMP
0,1 s 5s
Deceleration management in case of inversion or Stop
command
INVERTER
24V
BR
0,5 s
116
REPEAT LEAF DELAY
On Off
In case of a STOP command when the gate is on its
halfway, the leaves will repeat the "leaf delay" set on
menus 26-27
ALL
On
117
ALWAYS CLOSE
Off 240 seconds
In case of power failure, if the gate has been manually
open, it closes only after the set time has elapsed
(from
0 to 240 seconds)
as soon as the power is restored
ALL
Off
Off
Disabled
Opening
The gate opens and stay open till a new Start input.
The latch function uses the "Safety Edge 1" N.O. input
(Safety Edge 1 function is so disabled)
Closing
The gate closes and stay closed till a new Start input.
The latch function uses the "Safety Edge 2" N.O. input
(Safety Edge 2 function is so disabled)
Opening and closing
To enables both the opening and closing functions
above described.
The latch function uses the "Safety
Edge
1"
and
"Safety
Edge
2"
N.O.
inputs
(both safety edges are so disabled)
119
DISPLAY WRITING
SPEED
From 30% to 100%
See Note 2 at the end of the table
ALL
80%
120
BASIC MENU
Normal
Standard photocell without 10K control
Photo 1 10K
Photocell with 10K control
Normal
Standard photocell without 10K control
Photo 2 10K
Photocell with 10K control
123
DATE AND TIME
Mon - Sun
dd/mm/yyyy
Time
To set the day, the date and the time for the
management
of
the
programmed
openings.
(Only with full charge buffer battery)
ALL
- - - -
Opening time
Closing time
Days
Modify
To modify the pre-set time and day
Exit
Exit from menu
EMERGENCY
Off
PHOTO 1 TYPE
Normal
122
PHOTO 2 TYPE
Normal
SPECIAL MENU
ALL
ALL
113
118
LATCH
Off
124
CLOCK 1
To set a first time band in which keeping the gate open.
It is possible to set, in order: opening time, closing time
and the days on which you want to open and keep the
gate open
Off
ALL
ALL
ALL
Press OK to exit the special menu.
The special menu switches off automatically after 20 minutes
121
55