SET
DESCRIPTION
MODEL
DEFAULT
NOTE
32-
ORION BOX FAST
24Vdc electromechanic operator
35-
SURF
24Vdc electromechanic operator
39-
HT 270/390 24VDC
24Vdc hydraulic operator
43-
SURF FAST
24Vdc electromechanic operator
65
KITE LS
24Vdc electromechanic operator
50-
HALF TANK BR
Hydraulic operator - Series BR
(BRUSHLESS)
51-
SURF BR
Electromechanic swing operator -
Series BR
(BRUSHLESS)
52-
SATURN BR
Electromechanic operator - Series BR
(BRUSHLESS)
54-
SPRINT BR
Hydraulic barrier - Series BR
(BRUSHLESS)
55
KITE LS BR
Operatore elettromeccanico
- Serie BR
(BRUSHLESS)
56-
COMPACT BR
Hydraulic operator - Series BR
(BRUSHLESS)
57-
JOINT BR
Operatore idraulico - Serie BR
(BRUSHLESS)
58-
LEPUS BR (ABC)
Scorrevole con Encoder ABC - Serie BR
(BRUSHLESS)
4
GATES NUMBER
From 1 to 2
To set the number of motors to be managed
INVERTER
24V - BR
1
On
To reverse the opening with the closing or vice-versa
(both motors and limit-switches are reversed)
Off
Off
Automatic
Automatic
Open-stop-close-stop-open
Step by step type 1
Open-stop-close-open
Step by step type 2
2 button
Two buttons
Safety
Safety
Dead man
Dead man
Off
Semi-automatic logic -
(a START command opens and
another START closes - automatic closing disabled)
1 240
Setting from 1 second to 4 minutes
Off
The Start command is not accepted during pause
On
The Start command is accepted during pause
Off On
To start the working times self-learning
ALL
Choose direction
This menu is shown only if an Encoder RS 485 is
connected
- it allows to program one or two operators
with RS 485 Encoder, in automatic or manual mode
INVERTER
24V
BR
10
TEST START
Off On
To give a Start command for testing the automation
ALL
Off
11
BEAM LENGTH
3m - 4m - 5m - 6m
7m - 7,5m - 8m
This menu will be shown only if
the option
7-Barrier is set in the menu 3-MOTORS
. It allows to
choose the beam length
(values in meters)
INVERTER
BR
- - - -
12
SLOWDOWN
LIMIT SWITCH
Off On
This menu will be shown only if the option
5-Threephase/Bollards
is
set
in
the
menu
3-MOTORS.
It allows to activate the slowdown limit
switch on bollards
INVERTER
Off
13
LATCH PAUSE
Off On
If "ON" the operator complies with the pause time set
when the function "LATCH OPENING" is disabled. When
"OFF" the pause time set is not respected
INVERTER
24V
BR
Off
8
START IN PAUSE
Off
ALL
ALL
9
PROGRAMMING
Off
5
REVERSE MOTOR
Off
ALL
MENU
* Only for LEPUS FAST 220V. In case of LEPUS FAST 110V, choose the option 2-Sliding
BR
HALF
TANK
BR
3
MOTOR
6
LOGIC
Auto-
matic
24V
SURF
ALL
7
PAUSE TIME
Off
45