Field Service Procedure – Replacement PCU Kit, ST88, ST94 & ST144
Page
21
of
22
Document No
137738 Rev A
Copyright © Sea Tel, Inc 2012 - The information contained in this document is proprietary to Sea
Tel, Inc. This document may not be reproduced or distributed in any form without prior written
consent of Sea Tel, Inc.
22.
Secure
the
RG
‐
179
coax
cable
from
the
coax
switch
to
the
modem
using
a
cable
tie.
23.
Connect
the
AC
input
connection
and
secure
the
connection
to
the
assembly
using
a
cable
tie.
24.
Secure
the
red
and
green
RG
‐
60
coax
cables
to
the
red
and
green
RG
‐
179
coax
cables
using
a
7/16”
wrench.
25.
Reconnect
the
four
RG
‐
60
coax
cables
to
the
coax
switches
matching
the
colors
to
the
labels
on
the
mounting
plate.
26.
Reconnect
the
IDC
connector
to
the
termination
block
on
the
PCB.
27.
Secure
the
grounding
point
to
the
screw
securing
the
termination
PCB
using
a
#1
Phillips
screwdriver.
Apply
Loctite
242
to
the
thread.
Summary of Contents for ST144