❻ Take a moment to check for leaks again and verify additional flow through the system.
❼ Let the system run for 5 minutes and then increase the pressure by turning the Pressure Adjustment
Needle Valve clockwise until it reaches 700 psi.
❽ Do another quick check for leaks.
Setting The Pressure Relief Valve
❶ Slowly increase pressure to 950 psi by turning the Pressure Adjustment Needle Valve on the Control
Panel clockwise.
❷ Using an Allen wrench, adjust the pressure relief valve until it opens. You should see water flow into
the clear bypass hose and a slight drop in pressure on the Membrane Pressure Gauge.
❸ Reduce pressure by turning the Pressure Adjustment Needle Valve counterclockwise to operating
pressure of 850 psi.
❹ Verify output flow to 5 gallon bucket.
❺ Let system operate, discarding water for 15 minutes before testing, checking one last time for leaks.
❻ At the end of 15 minutes, fill 5 gallon bucket with product water.
Sea Clear Watermakers™ Manual - Version 3-B
Page 32