950-0203-revK - 4 - March 1, 2016
PARTS INCLUDED WITH UNIT
Wall-mounted Indoor unit
Outdoor Unit
Wall Bracket
Drain Fitting
Remote Control
Installation Manual
Batteries for Remote Control (2 AAA)
Terminal Label
Remote Control Holder
Adapter:
1/2"
F to 3/8”M (9510198) with 9K indoor and/or
12K unit.
3/8”F to 1/2"M (9510197) with 18K and/or 12K
indoor unit(s).
Adapter:
1/4
"F to 3/8”M (951-0251) – 2 pcs,
1/2"F to 3/8”M (951-0252) – 2 pcs,
1/2"F to 5
/8”M (951-0253) – 2 pcs
3/8"F to 1/4
”M (951-0254),
5/8
"F to 3/8”M (951-0255),
3/8"F to 1/2
”M (951-0256),
5
/8”F to 1/2"M (951-0257)
Operation Manual
Drain Tubing 6 ft.
Note: The outdoor unit can be connected to different types of indoor unit as followings:
Console:
9K - SMZC9H4ZIGX; 12K - SMZC12H4ZIGX, 18K - SMZC18H4ZIGX.
Cassette:
12K - SMZCA12H4ZIGX, 18K - SMZCA18H4ZIGX, 24K
– SMZCA24H4ZIGX
Floor / Ceiling:
9K - SMZFC9H4ZIGX; 12K - SMZFC12H4ZIGX, 18K - SMZFC18H4ZIGX,
24K
– SMZFC24H4ZIGX.
Ducted:
9K - SMZD9H4ZIGX; 12K - SMZD12H4ZIGX, 18K - SMZD18H4ZIG, 21K
– SMZD21H4ZIG,
24K
– SMZD24H4ZIG.
For the detail information about the included parts and connecting for above indoor units, please refer to the
manual to be included with each indoor unit.
INSTALLER SUPPLIED PARTS
The following additional Items are required for proper installation.
Refrigerant line set: Insulated copper tubing:
o
9K Indoor
– 1/4” (liquid line) and 3/8” (suction line).
o
12K Indoor
–1/4” (liquid line) and 1/2” (suction line) for SHE12H4ZIGX;
1/4” (liquid line) and 3/8” (suction line) for SHE12H4ZIGB
o
18K Indoor
– 1/4” (liquid line) and 1/2” (suction line).
o
24K Indoor
– 1/4” (liquid line) and 5/8” (suction line).
Flare nuts 2 ea. required per line, see above (line set) for size.
Vinyl UV resistant tape.
Supply Power:
o
50 amp circuit breaker
Interconnect wire cable:
o
4C 14 AWG stranded (Recommended)/ 4C 16 AWG stranded (minimum) per indoor unit.
Refrigerant - R410A required for additional line set charge.
Sealing putty.
1/4” to 5/16” access fitting adaptor (PN: QC-S5)
Mounting hardware - Wall anchors, condenser pad etc.
Surge protector (highly recommended)
VERY IMPORTANT:
Condensate pump P/N 4100130
can not
be powered from the indoor unit. Power
connections must be made at outdoor unit supply power.
Main system breaker or disconnect sized per unit requirements should be mounted adjacent to outdoor unit.