SDC EntryCheck 921P Installation Instructions Manual Download Page 6

Configure Sense Input  

Default:  Door Sense 

The Sense Input (E8) can be programmed for either DOOR 
SENSE or INHIBIT.

Press:  10 # Input #

Input=0 for Door Sense; =1 for Inhibit

When programmed for DOOR SENSE, if an open condition on 
the input occurs before access is granted (with an entry code or 
with the request-to-enter input) a FORCED ENTRY output will 
occur.  If an open condition remains 60 seconds after a relay 
activation for access, a DOOR AJAR output will occur.  NOTE: 
Function 11 and/or 12 must also be enabled to use Door Sense.  

When programmed for INHIBIT, a closed condition on the input 
will prevent Relay #1 from activating when access is requested 
with an entry code.  This mode is typically used with an external 
timer to disable the access device at certain times.

Select Keypad Active Output

Default:  No Output

Sets which output activates when any keys are pressed.  This 
output is timed.  If toggle mode is selected for the output, the timer 
value defaults to 2 seconds.

Press: 14 # 

Output

#  

Output=Output to Activate(0-4)

1=Main Relay;  2=Auxiliary Relay;  3=Output #3;  4=Output #4; 

0=No Output

Select Keypad Lockout Output

Default:  No Output

Sets which output activates when the keypad is “locked out” after 
too many incorrect entry code attempts. The lockout time is 60 
seconds.

Press: 13 # 

Output

#  

Output=Output to Activate (0-4)

1=Main Relay;  2 = Auxiliary Relay;  3=Output #3; 4=Output #4;  

0=No Output / Lockout Disabled

Select Alarm Shunt Output

Default:  No Output

Sets which output activates during the time access is granted.  
(Use this output ot shunt alarm contacts attached to the access 
door.)  This output may be timed or toggled.

Press: 15 # 

Output

#  

Output=Output to Activate(0-4)

1=Main Relay;  2=Auxiliary Relay;  3=Output #3;  4=Output #4; 

0=No Output

Select Request-to-Exit Output

Default:  No Output

Sets which output activates when the Request-to-Exit input is 
grounded.  This output may be timed or toggled.

Press: 16 # 

Output

#  

Output=Output to Activate(0-4)

1=Main Relay;  2=Auxiliary Relay;  3=Output #3;  4=Output #4; 

0=No Output

REX input terminates toggle of Main Relay

Main Relay On-time

Default:  02 Seconds

Sets the length of time the Main Relay activates when triggered.

Green LED is on when Main Relay is active.

Press: 21 # 

Seconds

#  

Seconds=Output time in seconds (0-60)

Auxiliary Relay On-time

Default:  02 Seconds

Sets the length of time the Auxiliary Relay activates when triggered.

Press: 22 # 

Seconds

#  

Seconds=Output time in seconds (0-60)

(Typical Programming cont.)

See the following example that sets entry codes 1234 for normal 
and 5678 for toggle operation.

Press:  01 # User # 1 2 3 4 # 1 2 3 4 # 1 #

01=Programming Step;  1234=Entry Code;  1=Main Relay

Press:  01 # User # 5 6 7 8 # 5 6 7 8 # 20 #

01=Programming Step;  5678=Entry Code;  20=Auxiliary Relay

toggle

Anti-Tamper Output

Default:  No Output

Sets which output activates when the Anti Tamper switch on the 
back of the keypad is activated. 

Press: 17 # 

Output

#  

Output=Output to Activate(0-4)

0=No Output;  2=Auxiliary Relay;  3=Output #3;  4=Output #4;  

Erasing All Entry Codes

WARNING:  PERFORMING THIS COMMAND WILL REMOVE 

ALL ENTRY CODES FROM THE MEMORY

Press: 97 # 0 0 0 0 0 0 #  0 0 0 0 0 0 #  

Note: 

The green indicator will light while the memory is being 

erased.  This may take up to 15 seconds

.

P:\INSTALLATION INST\Access Controls\INST-921\INST-921P.vsd     Rev D    10-14     Page 6

Select Forced Entry Output

Default:  No Output

Sets which output activates if the DOOR SENSE input opens 
before access is granted.  This output is timed and configured 
by the relay “On-time”.

Press:  11 # Output #

Output=Output to Activate(0-4)

1=Main Relay;  2=Auxiliary Relay;  3=Output #3;  4=Output #4;  

0=No Output

Select Door Ajar Output

Default:  No Output

Sets which output activates if the DOOR SENSE input stays 
open 60 seconds after access is granted (door ajar time is 
adjustable using Function 25).  This output is not timed.

Press:  12 # Output #

Output=Output to Activate (0-4)

1=Main Relay;  2=Auxiliary Relay;  3=Output #3;  4=Output #4;  

0=No Output

Erasing Multiple Users (Sequential)

Press: 09 # 1

st

User

# Number of users #  

1

st

User =Starting user number to delete

Number of users = Total number of consecutive users  to delete

The yellow indicator will flash quickly while the 921P erases the 
user from  memory.  The green indicator will light when the code is 
erased.

Summary of Contents for EntryCheck 921P

Page 1: ...ushbutton to provide codeless activation of the Main Relay Auxiliary Relay Output 3 or Output 4 programmable The ALARM SHUNT signal is available when access is granted This signal can be programmed to...

Page 2: ...Assign a user Card PIN only Step 1 Enter 9 123456 Enter programming mode default master code Step 2 Enter 06 002 9876 9876 1 Present card Assign card to User 002 with a PIN code of 9876 Activate the...

Page 3: ...upply DTRX POWER 6 5 4 3 2 1 2 1 1 2 3 1 2 3 1 2 3 4 5 6 7 8 MAIN AUX WIRES JP2 POWER LED DTRX JP1 KEYPAD BACK DTRX PIGTAIL USER PROVIDED 6 CONDUCTOR JACKETED CABLE 100ft MAX RED BLK GRN GRY PINK BLU...

Page 4: ...oller Connect the door switch to the keypad s SENSE terminal E8 and ground terminal Either E1 E4 E5 or E7 If an inhibit switch or timer is going to be used for temporarily disabling the keypad route t...

Page 5: ...rmined by the entry code length setting Leading zeros will have to be entered by the user when entering their code to gain access Erasing a Single User Press 02 User User User The user number to delet...

Page 6: ...REX input terminates toggle of Main Relay Main Relay On time Default 02 Seconds Sets the length of time the Main Relay activates when triggered Green LED is on when Main Relay is active Press 21 Secon...

Page 7: ...te Output 3 On time Default 02 Seconds Sets the length of time Output 3 activates when triggered Press 23 Seconds Seconds Output time in seconds 0 60 99 Toggle Mode Beep Sounds Anti Tamper Activation...

Page 8: ...0 14 Page 8 2X Mount at slots MOUNTING TO SINGLE GANG RECESSED OUTLET BOX 4X Mount at holes With supplied screws and hole expansion anchors SURFACE MOUNT STANDARD WALL MOUNT SINGLE GANG BOX MOUNT OPTI...

Page 9: ...4X Mount at holes P INSTALLATION INST Access Controls INST 921 INST 921P vsd Rev D 10 14 Page 9 OPTIONAL SHROUD SURFACE MOUNT WITH OPTIONAL SHROUD POST MOUNT WITH SHROUD 4 4...

Reviews: