SDC EntryCheck 921P Installation Instructions Manual Download Page 3

CAUTION

IF THE UNIT IS AC POWERED, MAKE SURE

THAT THE SECONDARY OF THE SYSTEM IS 

ISOLATED FROM EARTH GROUND

!

!

Fig. 2 Typical Wiring

BEEPER 
LEVEL 
JUMPER
(JP1)

DTRX

JP1

BACK

RED/GREEN
POWER/ACCESS
INDICATOR

YELLOW
“LOCKOUT/
PROGRAM”
INDICATOR

KEYPAD

FRONT

PROX 

Antenna

KEYPAD

DTRX

CONNECTOR

ANTI-

TAMPER

SWITCH

(8) SENSE

(7) GROUND

(6) REQUEST TO EXIT

(5) GROUND

(4) GROUND

(3) OUTPUT 3

(2) OUTPUT 4

KEY PAD POWER

12-24 VOLTS

AC OR DC

AUXILIARY RELAY

2 AMPS @ 28VDC MAX

}

FAIL SAFE

MAIN RELAY

5 AMPS @ 28VDC MAX

12v or 24v 

Power Supply

DTRX

POWER

+

-

6   5   4   3   2   1

2   1

1   2   3 1   2   3 1   2   3   4   5   6   7   8

MAIN

AUX

WIRES

JP2

POWER

LED

DTRX

JP1

KEYPAD

BACK

DTRX

PIGTAIL

USER PROVIDED  

6 CONDUCTOR

JACKETED CABLE

(100ft MAX)

RE
D

BL
K

GR
N

GR
Y

PI

N

K

BL
U

N/C

COM

N/O

N/C

COM

N/O

+

-

(1) GROUND

C

N/O

N/C

C

N/O

N/C

N/C DOOR 

POSITION

SWITCH

N/O 

REQUEST-

TO-EXIT
SWITCH

EARTH 

GROUND 

CONNECTION

AUXILIARY OUTPUTS

100mA MAX TO COMMON

FAIL SECURE

COMMON

}

MASTER CODE
RESET JUMPER
(JP2)

P:\INSTALLATION INST\Access Controls\INST-921\INST-921P.vsd     Rev D    10-14     Page 3

}

KEYPAD
POWER

ACCESSORY

TERMINALS

(E1-E8)

MAIN

RELAY AUXILIARY

RELAY

MASTER CODE
RESET JUMPER
(JP2)

EXTERNAL 

BOARD

DTRX

POWER

+

-

6   5   4   3   2   1

2   1

1   2   3 1   2   3 1   2   3   4   5   6   7   8

MAIN

AUX

WIRES

JP2

POWER

LED

DTRX PIGTAIL

Summary of Contents for EntryCheck 921P

Page 1: ...ushbutton to provide codeless activation of the Main Relay Auxiliary Relay Output 3 or Output 4 programmable The ALARM SHUNT signal is available when access is granted This signal can be programmed to...

Page 2: ...Assign a user Card PIN only Step 1 Enter 9 123456 Enter programming mode default master code Step 2 Enter 06 002 9876 9876 1 Present card Assign card to User 002 with a PIN code of 9876 Activate the...

Page 3: ...upply DTRX POWER 6 5 4 3 2 1 2 1 1 2 3 1 2 3 1 2 3 4 5 6 7 8 MAIN AUX WIRES JP2 POWER LED DTRX JP1 KEYPAD BACK DTRX PIGTAIL USER PROVIDED 6 CONDUCTOR JACKETED CABLE 100ft MAX RED BLK GRN GRY PINK BLU...

Page 4: ...oller Connect the door switch to the keypad s SENSE terminal E8 and ground terminal Either E1 E4 E5 or E7 If an inhibit switch or timer is going to be used for temporarily disabling the keypad route t...

Page 5: ...rmined by the entry code length setting Leading zeros will have to be entered by the user when entering their code to gain access Erasing a Single User Press 02 User User User The user number to delet...

Page 6: ...REX input terminates toggle of Main Relay Main Relay On time Default 02 Seconds Sets the length of time the Main Relay activates when triggered Green LED is on when Main Relay is active Press 21 Secon...

Page 7: ...te Output 3 On time Default 02 Seconds Sets the length of time Output 3 activates when triggered Press 23 Seconds Seconds Output time in seconds 0 60 99 Toggle Mode Beep Sounds Anti Tamper Activation...

Page 8: ...0 14 Page 8 2X Mount at slots MOUNTING TO SINGLE GANG RECESSED OUTLET BOX 4X Mount at holes With supplied screws and hole expansion anchors SURFACE MOUNT STANDARD WALL MOUNT SINGLE GANG BOX MOUNT OPTI...

Page 9: ...4X Mount at holes P INSTALLATION INST Access Controls INST 921 INST 921P vsd Rev D 10 14 Page 9 OPTIONAL SHROUD SURFACE MOUNT WITH OPTIONAL SHROUD POST MOUNT WITH SHROUD 4 4...

Reviews: