Fit remaining spindle to inside - non code side.
Step 3
Take the adaptor kit, item 13 on the contents page. Cut the two M5 countersunk head bolts to length to suit
the door thickness; i.e. door thickness plus a maximum of 10mm ( ⁄ ”) (no more than 5mm ( ⁄ ”) should enter
the front plate). Hold the front plate, with the three hole neoprene seal, against the door over the protruding
spindle. From the other side of the door, fix the adaptor plate to the front plate using the two M5
countersunk bolts. Before tightening up the fixings, make sure that the spindle hole is centrally positioned
over the follower. Do not use excessive force.
Step4
Cut two of the long socket head bolts to the required length for your door. Approximate overall length
should be door thickness plus 25mm (1”), to allow about 10mm ( ⁄ ”) of threaded bolt to enter the front
plate. Place the neoprene gasket over the adaptor plate. Use the screw with the ‘T’ shaped Allen key, to fix
the back plate to the front plate through the TOP holes. Using the 20mm ( ⁄ ”) socket head bolt fix the back
plate through the BOTTOM hole to the adaptor plate. Do not use excessive force.
Step 5
Check that the lever handles are correctly fitted for the hand of door. To change the hand of a lever handle,
loosen the grub screw with the small Allen key, reverse the lever handle and fully tighten the grub screw.
Step 6
Before closing the door, enter the code and check that the latchbolt retracts when the lever handle is
depressed. Now check the operation of the inside lever handle. If there is any binding of the handles or latch
then loosen the top and bottom bolts and reposition the plates slightly until the correct position is found,
and then re-tighten the bolts.
Model CL610/615 Installation Instructions
The model CL610/615 has a tubular, deadlocking, mort ice lat ch a nd m ay be used as a new installation on
a door, or where an existing latch is to be replaced.
When installing on a fire door, fire kit is required. Please refer to instructions on page 12 and 13.
Note: Ensure enough room for the latch support post Please align the template to suit the locks
backset: 60mm (2 ⁄ ”) standard or 70mm (2 ⁄ ”).
Step 1
Lightly mark a height line on the edge and both faces of the door, and on the door jamb, to indicate the top
of the lock when fitted. Crease the template (standard) along the dotted line, and tape it to the door with the
top in line with the height line. Mark the 3 x 10mm ( ⁄ ”) and the 1 x 30mm (1 ⁄ ”) holes.
Note: When fitting to a door with existing 54mm (2 ⁄ ”) through hole, only top two 10mm ( ⁄ ”)
holes need to be marked and drilled.
Mark the centre of the door edge on the Centre Line of Latch. Remove the template and apply it to the other
side of the door, aligning it accurately with the first Centre Line of Latch mark. Mark the 4 holes again.