background image

VisionGaurd 8000-  Page 19

when the door is open.  This type of door circuit is usually found on Ford vehicles.

Pin 12

GREEN WIRE

: Negative Door Input (-).  Connect to the door switch circuit wire that shows ground

when the door is open.

Pin 13

WHITE/BLACK WIRE

: Hood Pin Input (-). Connect the to the hood pin switch. The switch must

provide a ground output when switch is opened.  

Pin 14

ORANGE WIRE

: Armed Output (-) 500 mA.  The Orange wire provides a ground output while armed

to activate a relay for starter defeat and anti-grind protection. 

Pin 15

VIOLET/WHITE WIRE

: Factory Disarm Output (-) 500 mA. The Violet/white wire provides a ground

output on disarming and before remote starting to disarm a factory security system. Connect to the

wire that requires a ground pulse to disarm the factory security system. 

Pin 16

WHITE/VIOLET WIRE

: Camera Flash or Factory Rearm Output (-) 500 mA. Connect to optional

camera flash module or factory security system. Factory Rearm Mode - the White/violet wire provides

a ground output on remote start shutdown to rearm a factory security system. Connect to the wire that

requires a ground pulse to rearm the factory security system. 

Pin 17

BROWN WIRE

: Siren Output (+) 3A.  The Brown wire must connect to the siren’s red wire.  The Black

siren wire must be grounded.

Pin 18

GRAY WIRE

: Auxiliary 1 Output (-) 500 mA. Connect to a relay for an optional feature such as trunk

release, etc.  This output may be programmed for momentary, timed, or latched operation.

Pin 19

WHITE WIRE

: Parking Light Output (+/-) relay. Connect the White wire to the circuit that shows

+12V or ground only when the parking lights are on and set the internal parking light relay jumper to

the proper polarity. For parking light circuits exceeding 10 amps, a relay is required. For vehicle’s with

independent left and right parking light circuits, diodes must be installed to keep the circuits separate.

NOTE: Do not connect the WHITE wire to the vehicle’s headlight circuit.

Pin 20

BROWN/WHITE WIRE

: Horn Output (-) 500 mA. Connect to a relay to activate the vehicle’s horn

when the alarm is triggered.  This wire may instead be programmed as an ignition 3 relay trigger.

Plug-in Connectors

4-Pin White Connector: 

Dual stage shock sensor port.

2-Pin Blue Connector: 

Valet switch port.  Mount program switch in an area that is easily accessible from

the driver’s position.

2-Pin Red Connector: 

LED port.  Mount LED in an area where it may be easily seen from either side of

the vehicle.

3-Pin White Door Lock Connector: 

Door lock port.

· BLUE WIRE - negative unlock output (-) 500mA.  

· GREEN WIRE - negative lock output (-) 500mA.

3-Pin Blue Connector:

The plug-in network connector port is located on the side of the main module.

This network port may be used with the optional personal computer interface or Pocket PC for diagnostics,
software customization and expanded programming options.  The network also offers connection to several
optional accessories.  

See your dealer for more information.

2-Pin White Connector: 

Located on the side of the main module.

· GREEN WIRE - Parking Brake Input (-) For Manual transmission and/or vehicles equipped with a turbo

charged engine. Must be connected if using the Turbo Timer feature and/or Manual Transmission remote

start feature.

· BLUE WIRE - Optional negative start input 

Summary of Contents for VISIONGUARD 8000

Page 1: ...VISIONGUARD 8000 VEHICLE SECURITY SYSTEM WITH BUILT IN CAMERA AND REMOTE START PRODUCT MANUAL...

Page 2: ...ill be a maximum service charge of 25 00 per calendar year if required for repair and or replacement of any defective parts A copy of the original purchase receipt must accompany any products returned...

Page 3: ...wn Page 13 Quick Stop Page 13 Automatic Start Mode Page 13 Turbo Timer Feature Page 14 Manual Transmission Remote Starting Page 14 5 Extended Features Page 14 Ignition Door Locking Page 15 Ignition Do...

Page 4: ......

Page 5: ...Contents Main Unit with built in ScyNet Network Interface Port Two Way Full Color Picture Ready LCD Remote Transmitter Camera Remote Transmitter Receiver One Way 5 Button Random Code Remote Transmitte...

Page 6: ...1 output This output will remain on for as long as the button is pressed Button 4 Activates the Remote Start feature Button 5 is the Page Shift button Each time the Shift Button is pressed the LED on...

Page 7: ...ransmitter If all four transmitters are to be used with both cars program transmitters A and B into the first vehicle in the manner described above Program transmitters C and D by pressing the Shift b...

Page 8: ...en pressed together for 2 seconds Activates the Auxiliary 1 output normally used for trunk release Button 4 is the Confirmation button Pressing button 4 for 2 seconds activates the system s confirmati...

Page 9: ...replacement in time Depending on the amount of use the battery may last up to two months before it needs replacement When the battery needs replacing the system s operating range will decrease the LC...

Page 10: ...utton 4 The transmitter will beep once The transmitter will display CHIRP ON for on or CHIRP OFF for off NOTE SHOCK TURBO SENSOR 1 AND SENSOR 2 ARE NOT USED VALET To set the VALET mode ON or OFF 1 Pre...

Page 11: ...VisionGaurd 8000 Page 7 Camera Features...

Page 12: ...VisionGuard 8000 Page 8...

Page 13: ...s an impact to the vehicle An optional sensor is disturbed When the alarm triggers the siren will sound the horn will honk and the parking lights will flash If the system is triggered by the doors hoo...

Page 14: ...ne time silent operation Note The open zone warning chirps will not be bypassed when the system is Armed or Disarmed silently Passive Arming When programmed for the optional Passive Arming feature the...

Page 15: ...dure be sure to have the ignition key ready and know the location of the override switch To Emergency Override the system 1 Unlock the door using the key 2 Enter the vehicle The system will trigger an...

Page 16: ...icle in the event the system is accidentally disarmed With the Automatic Rearming feature enabled the alarm will automatically rearm an lock 30 seconds after disarming The Automatic Rearming feature f...

Page 17: ...Quick Stop The Quick Stop Feature allows you to exit the vehicle while keeping the engine running for quick stops To leave the vehicle running 2 While the engine is running push the Remote Start butt...

Page 18: ...remote start button on your transmitter parking lights will flash twice and stay on indicating Manual Start Mode is enabled turn off the Ignition switch the engine will remain running Open and close t...

Page 19: ...activation power sunroof control auxiliary lighting audio video system control and more The Pulsed operation setting allows an output to activate as long as the button is held one way transmitter onl...

Page 20: ...g 6 Verify with the owner the mounting locations for all visible components including the LED and Override switch 7 Verify with the owner the optional features of the VisionGuard 8000 and the features...

Page 21: ...e Siren Choose a siren mounting location that is away from heat sources such as exhaust manifolds and where it cannot be easily accessed from underneath the vehicle Be sure to face the siren downward...

Page 22: ...chless mode does not provide satisfactory operation Pin 3 WHITE RED WIRE Auxiliary 2 Output 500 mA Connect to a relay or module for an optional feature such as power window activation etc the output m...

Page 23: ...wire to the circuit that shows 12V or ground only when the parking lights are on and set the internal parking light relay jumper to the proper polarity For parking light circuits exceeding 10 amps a...

Page 24: ...olarity jumper will be visible next to the parking light relay Set the jumper for the correct polarity output as described below then reassemble the main unit case Parking Light Output Selects the pol...

Page 25: ...ystem Programming 2 Press Transmitter Button 3 The siren will chirp 6 times indicating that the reset signal was received All System Programming parameters are now set to factory default settings The...

Page 26: ...to Rearming Mode Disabled Enabled 3 Arming Chirps Siren Chirps On Silent Siren Horn Chirps On 4 Ignition Door Locking On Off Set Override Code 5 Ignition Door Unlocking Unlock All Unlock Driver Only O...

Page 27: ...for Auxiliary 2 14 Disarm with Auxiliary 1 When selected activating the Auxiliary 1 output usually used to open the trunk will disarm the alarm 15 Start in Valet Mode Selects whether or not the vehicl...

Page 28: ...to trigger a relay for Ignition 3 24 Turbo Timer When enabled if the emergency brake has been applied Ignition power will be kept On for a predetermined time 2min Factory Default from the application...

Page 29: ...POSITIVE HORN WIRE 12V Brown White HORN OUTPUT TO NEGATIVE HORN WIRE 12V Brown White HORN OUTPUT Positive Horn Honk Negative Horn Honk Blue Yellow Wire GLOW PLUG INPUT Yellow Wire IGNITION GLOW PLUG...

Page 30: ...igger using inverter or relays Reverse Polarity Vacuum Adding Actuators Follow the diagrams below for connecting basic door lock systems For Two Stage door lock systems separately unlocks driver and p...

Page 31: ...sionGuard 8000 is equipped with a dedicated Passenger Unlock output allowing Two Stage Door Lock operation When connected as shown below disarming the system will unlock only the driver s door Pressin...

Page 32: ...Page 28 VisionGaurd 8000 Two Stage Door Lock Diagrams cont d Two Stage Reverse Polarity Two Stage Adding Actuators...

Page 33: ...es with Part 15 of FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interfe...

Page 34: ...8000 Starter Diagnostics Starter doesn t start and parking lights flash 3 Times Engine RPM not detected Hood Trigger is active 4 Times Brake Trigger is active 5 Times Unit is in Valet service mode an...

Page 35: ...VisionGaurd 8000 Page 31...

Page 36: ...Unlock Output 500mA Blue Orange Remote Start Output 500mA Black Ground Red 12V Battery Input 3 Violet Door Trigger Input Green Door Trigger Input White Black Hood Trunk Input Orange Armed Output 500mA...

Reviews: