Scytek electronic ASTRA 300RS Product Manual Download Page 7

System Programming

The system programming is compatible with both the LCD transmitter or the standard AM transmitter.

Enter System Programming:

1. Turn on ignition.

2. Within 5 seconds, press the valet switch 5 times.

· The horn will provide three chirps, indicating that you have entered Programming.

3. Press the valet switch the number times equal to the System Parameter you want to change.

· The horn will chirp each time the valet switch is pressed.

4. Within 5 seconds, press the transmitter button corresponding to the desired operating mode for

that System Parameter.

· The horn will chirp to indicate the setting.

 1 chirp = Button 1

 2 chirps = Button 2

 3 chirps = Button 3

5. When you are finished, turn off the ignition to save the changes.

Default Reset

Following this procedure will set all System Programming Parameters to factory default settings.

1. Enter System Programming.

2. Press Transmitter Button 3.

· The horn will chirp 6 times indicating that the reset signal was received.

· All System Programming parameters are now set to factory default settings.

· The Valet Mode is off.

3. Turn off ignition.

Programmable System Options

The following is a description of the programming options of the system. Some of the program branches control more

than one option, and may require accessing a particular branch number twice in order to program all desired fea-

tures.

3. Lock/Unlock Chirps. Selects between normal and silent operation. 

5. Extended Parking Lights. When Enabled, upon Disarming Parking lights will turn On for 30 seconds or until the

Dome light turns Off

Reset Mobilink (Galaxy Mobile) module.

6. Ignition Door Locking / Valet Code Set. This dual program branch selects Ignition Door Locking, and programs the

optional Emergency Valet Code. Ignition Door Locking. Selects whether or not the system will automatically lock the

doors 5 seconds after the ignition key is turned on. Valet Code Set. Changes the Emergency Valet Code for a higher

level of security.

7. Ignition Door Unlocking. Selects whether or not the system automatically unlocks the doors when the ignition is

turned off.

8. Door Unlock Pulse. Selects between one pulse or two pulse operation for the door unlock output. Many new import

vehicles’ factory door locking systems require two pulses on the proper wire to unlock the doors. These systems can

be interfaced directly without the use of relays or any additional circuitry by programming the system for double un-

lock pulse. also programs to pulse the ignition before unlock

9. Door Lock Pulse Length. Selects between a 1-second, 3-second or 0.1 second output for door locking and unlocking.

Program to 3 seconds for vehicles equipped with vacuum door locking systems. 0.1 seconds for vehicles that roll

windows up or down when lock/unlock output is at 1 second.

System Programming

Summary of Contents for ASTRA 300RS

Page 1: ...ASTRA 300RS REMOTE START WITH KEYLESS ENTRY AUTOMATIC TRANSMISSION ONLY PRODUCT MANUAL...

Page 2: ...iary 1 output This output will remain on for as long as the button is pressed Button 4 Activates and deactivates the remote start Jumper Selection Carefully separate the top and bottom halves of the m...

Page 3: ...may last up to six months or more before it needs replacement When the battery needs replacing the system s operating range will decrease or the transmitter LED may not be as bright In order to chang...

Page 4: ...ration and used to add a number of optional features such as power trunk release power window activation power sunroof control auxiliary lighting audio video system control and more The Pulsed operati...

Page 5: ...testing vehicle circuits Never use a test light 10 Always look before drilling any holes or mounting self tapping screws Be sure fuel lines and exterior wiring looms are clear as they are often close...

Page 6: ...ng light circuits diodes must be installed to keep the circuits separate NOTE Do not connect the WHITE wire to the vehicle s headlight circuit Pin 3 BLACK Ground Input The Black wire must connect to a...

Page 7: ...anch number twice in order to program all desired fea tures 3 Lock Unlock Chirps Selects between normal and silent operation 5 Extended Parking Lights When Enabled upon Disarming Parking lights will t...

Page 8: ...the tach wire must be connected 21 Remote Start Program This dual program branch sets the engine mode for Gas or Diesel and learns the vehicle s RPM threshold Learning the RPM threshold automatically...

Page 9: ...Engine Run Time 15 Min 25 Min 18 Automatic Start Interval 2 Hour 1 Hour 19 Tachless Sense Crank Time Normal Extended Super Extended 20 Engine Sense Mode Smart Start Smart Start Monitor Disabled Data B...

Page 10: ...Negative Trigger Positive Trigger additional 2 relays reqiured Reverse Polarity Adding Actuators Door Lock Diagrams...

Page 11: ...een Lock Astra 300RS White Violet Factroy Disarm Out Blue Orange Ground When Running Out Brown White Horn Out Gray Trunk Release Out White Black Hood Trigger In Green White Brake Light In Black Gray R...