SCS WSMONITOR1 User Manual Download Page 3

TB-9036

 Page 3 of 4

© 2015 DESCO INDUSTRIES, INC.

Employee Owned

Calibration

The Constant Monitors are calibrated to standards 

traceable to NIST.  Frequency of recalibratrion should 

be based on the critical nature of those ESD sensitive 

items handled and the risk of failure for the ESD 

protective equipment and materials.  In general, we 

recommend that calibration be performed annually.

Use the SCS 

TMTOOL

 Verification Tester to perform 

periodic testing (once every 6-12 months) of the 

Constant Monitors.  The Verification Tester can be 

used on the shop floor within a few minutes virtually 

eliminating downtime, verifying that the monitor is 

operating within tolerances.

Safety Information

Read, understand, and follow all safety information 

contained in these instructions prior to the use of 

Constant Monitors WSMONITOR1, WSMONITOR 2, 

and WSMONITOR3.  Retain these instructions for future 

reference.

Warning

To reduce the risks associated with fire and explosion:

•  Do not use in an explosive environment - monitor is 

not designed to be intrinsically safe.

To reduce the risks associated with medical device 

malfunction:

• 

Persons with heart pacemaker devices should never 

use this monitor.

To reduce the risks associated with hazardous voltage 

and fire:

•  Use only the power supply provided by SCS and 

specified for the country of use.

• 

Do not position the monitor accessories or other 

equipment where unplugging the power supply is 

difficult.

•  Always locate the power source (socket or outlet) 

near the equipment. The power supply plug serves 

as the disconnect device.

• 

Do not modify or attempt to service the power 

supply or monitor; there are no user serviceable 

parts.

• 

Do not use the power supply if damaged;

• 

Replace power supply if damaged using only SCS 

supplied parts.

•  Do not use the Constant Monitors WSMONITOR1, 

WSMONITOR 2, WSMONITOR3 or their power 

supplies outdoors in wet/humid environments.

•  Do not use the  Constant Monitors WSMONITOR1, 

WSMONITOR 2, WSMONITOR3 or their power 

supplies outside of the operating conditions listed in 

this user guide.

• 

Always follow instructions for installation as stated in 

this user guide.

Caution

To reduce the risks associated with environmental 

contamination:

• 

Dispose of this monitor in accordance with all 

applicable local and government regulations.

Notice

To reduce the risk of ESD damage to components or 

assemblies being handled:

•  Monitor must be checked periodically to verify each 

test mode is functioning correctly.

•  Ensure proper operation of monitor by performing 

operational verification test as required.

• 

Ensure tester is properly grounded.

Figure 7.  SCS 

TMTOOL

 Verification Tester

Specifications

Monitor Type

Impedence - single-wire

Circuitry

Solid-state, surface mount

Alarm

Audible and visible (LED)

Alarm Threshold

8 megohms

Power

120VAC, 230VAC

Adjustments

None required

Calibration

See SCS 

TMTOOL

Item

Dimensions

Weight

WSMONITOR1 0.9" H x 1.8" W x 1.3" D

1.2 oz.

WSMONITOR2 1.0" H x 2.4" W x 2.3" D

1.6 oz.

WSMONITOR3 1.0" H x 4.0" W x 2.4" D

2.6 oz.