WSMONITOR1
1.
Check that you have received all parts: monitor,
power ground adapter and two mounting screws.
2. Using the mounting screws, mount the monitor
under the work bench. (Other suggested mounting
locations include the bench top and under bench
shelving.)
3.
Plug the power/ground adapter into the back of the
monitor and into a 3-prong 120VAC outlet.
WSMONITOR3
1.
Check that you have received all parts: monitor,
remotes, four screws, power/ground adapter, mat
cord and industrial hook and loop.
2. Using the hook and loop, mount the monitor under
the workbench shelf.
3.
Mount the remotes to the work bench with screws.
4. Connect the monitor to the STACKJACK.
5. Remove a plastic cap from STACKJACK and snap it
to the mat.
6.
Connect the other mat snap to ground. (Cable not
included.)
7.
Plug the power/ground adapter into the back of the
monitor and into a power outlet.
Note: The mat connection monitoring function can be
connected to a workbench with a hard worksurface.
AC ADAPTER
BENCH MAT
MONITOR
HOOK & LOOP
WORK BENCH
STACKJACK
REMOVE CAP
(cable not
included)
Figure 5. Installing the WSMONITOR2 Constant Monitor
WSMONITOR2
1.
Check that you have received all parts: monitor,
power/ground adapter and two mounting screws.
2. Using the mounting screws, mount the monitor
under the work bench. (Other suggested mounting
locations include the bench top and under bench
shelving.)
3.
Plug the power/ground adapter into the back of the
monitor and into a 3-prong 120VAC outlet.
AC ADAPTER
BENCH MAT
MONITOR
SHELF
REMOTE
REMOTE
HOOK & LOOP
WRIST STRAP
WRIST STRAP
WORK BENCH
(cable not
included)
STACKJACK
REMOVE CAP
Figure 6. Installing the WSMONITOR3 Constant Monitor
AC ADAPTER
MONITOR
SCREWS
WRIST STRAP
WORK BENCH
Figure 4. Installing the WSMONITOR1 Constant Monitor
Operation
• Place a wristband on your wrist and plug the
coiled cord banana plug into the monitor’s banana
jack. The monitor will display a green light when
a functional wrist strap with good skin contact is
connected to the unit.
•
The unit will sound an alarm and display a red light
if the wrist strap becomes defective or if the person
is not in contact with the wristband.
•
Unplug the wrist strap coiled cord from the unit to
stop the alarm.
•
Monitor will alarm if the continuity from the monitor
to the mat to ground is lost.