Safety Information

Please read, understand, and follow all safety 

information contained in these instructions prior to the 

use of this device. Retain these instructions for future 

reference.

Intended Use

The SCS WS Aware Monitor is a dual workstation 

continuous monitor for operators, ESD worksurfaces 

and metal tools.  It continuously monitors the 

path-to-ground integrity and body voltage of two 

operators, as well as the path-to-ground integrity for two 

conductive or dissipative worksurfaces and two metal 

tools.  It also continuously monitors for electromagnetic 

interference (EMI) on two metal tools which may cause 

electrical overstress (EOS) damage.  The WS Aware 

Monitor eliminates the need for periodic testing and 

record keeping of wrist straps.
The systems must be installed as specified in this user 

guide in an indoor commercial/industrial environment, 

and have not been evaluated for other uses or locations. 

If the equipment is used in a manner not specified 

by the manufacturer, the protection provided by the 

equipment may be impaired.

Warning

To reduce the risks associated with hazardous voltage 

and fire:

•  Do not use the power supply if damaged

•  Replace power supply if damaged using only SCS 

supplied parts.

•  Do not modify or attempt to service the power 

supply. Return to SCS for service.

•  Do not use the WS Aware Monitor or its power 

supply outdoors or in wet/humid environments.

•  Do not use the WS Aware Monitor or its power 

supply outside of the operating conditions listed in 

this User Guide.

•  Use only a dry cloth when cleaning.
To reduce the risks associated with hazardous voltage:

•  Use only the power supply provided by SCS and 

specified for the country of use.

•  Do not simultaneously power the WS Aware Monitor 

with the power supply and the RJ45 data cable.

•  Do not position the monitor accessories or other 

equipment where unplugging the power supply is 

difficult.

•  Always locate the power source (socket or outlet) 

near the equipment. The power supply plug serves 

as the disconnect device.

Caution

To reduce the risks associated with environmental 

contamination:

•  Dispose of monitor and power supply in accordance 

with all applicable local and government regulations.

Notice

To reduce the risk of damage to components or 

assemblies being handled:

•  Monitor must be checked periodically to verify each 

test mode is functioning correctly.

•  Ensure proper operation of the monitor by 

performing operational verification test as required.

•  Always properly ground your tools and dissipative 

surfaces to before connecting them to the WS 

Aware Monitor.

FCC

This equipment has been tested and found to comply 

with the limits for a Class A digital device, pursuant to 

Part 15 of the FCC Rules.  These limits are designed 

to provide reasonable protection against harmful 

interference when the equipment is operated in a 

commercial environment.  This equipment generates, 

uses, and can radiate radio frequency energy and, if not 

installed and used in accordance with the instruction 

manual, may cause harmful interference to radio 

communications.  Operation of this equipment in a 

residential area is likely to cause harmful interference 

in which case the user will be required to correct the 

interference at his own expense.

Industry Canada ICES-003 Compliance:

CAN ICES-3 (A)/NMB-3(A)

Environmental Conditions

This equipment has been tested and found to be safe to 

operate within these environmental conditions.
This is not a warranty of equipment performance within 

these conditions.

•  Indoor use only

•  Ingress Protection: IPX0

•  Altitude: Up to 2,000 m

•  Mains supply voltage fluctuations up to ± 10% of the 

nominal voltage.

•  Transient over-voltages up to the levels of 

overvoltage category II.

•  Temporary over-voltages occurring on mains supply.

•  Pollution degree 2.

•  Temperature: Maximum 110°F / 43°C, Minimum 

50°F / 10°C

•  Humidity: Maximum relative humidity 80% for 

temperatures up to 31°C decreasing linearly to 50% 

relative humidity at 40°C.

Summary of Contents for TB-9079

Page 1: ...erator generates or comes in contact with voltage that would be dangerous to an ESD susceptible item The WS Aware Monitor continuously monitors two metal tools for electromagnetic interference EMI EMI...

Page 2: ...into a database for on going quality control purposes SMP allows you to pinpoint areas of concern and prevent ESD events Quantifiable data allows you to see trends become more proactive and prove the...

Page 3: ...a metal tool for proper conductive resistance and electromagnetic interference EMI Use 25 28 AWG wire to connect the metal tool to this terminal I Monitored Tool 2 Terminal Monitors a metal tool for p...

Page 4: ...or remote connectors located on the left side of the WS Aware Monitor 5 Route the mini DIN operator remote cables from the left side of the WS Aware Monitor to their respective operator remotes Connec...

Page 5: ...re not included Operator Remote Operator Remote Cable WS Aware Monitor Left Side Grounded Metal Tool NOTE Worksurface must have a conductive layer such as Dual Layer Rubber or Dissipative 3 Layer Viny...

Page 6: ...N SMP must be installed to a PC prior to using this procedure DYNAMIC IP PROCEDURE 1 Verify that the Ethernet cable is securely connected to your network and WS Aware Monitor The LEDs on the Ethernet...

Page 7: ...est 909 627 9634 Website StaticControl com 5 A message will appear and display Starting SMP Server Click the SMP Server icon located in the Windows taskbar 6 SMP Server will now indicate Active server...

Page 8: ...rial Drive Sanford NC 27332 East 919 718 0000 West 909 627 9634 Website StaticControl com 8 Open SCS SMP Admin 9 The window for SMP Server Admin will appear 1 unassigned is representative of the WS Aw...

Page 9: ...d NC 27332 East 919 718 0000 West 909 627 9634 Website StaticControl com 10 Enter a building name and then click the OK button 11 The building name will appear on the navigation pane in SMP Server Adm...

Page 10: ...Sanford NC 27332 East 919 718 0000 West 909 627 9634 Website StaticControl com 13 Enter a floor name and then click the OK button 14 The floor name will appear on the navigation pane in SMP Server Adm...

Page 11: ...st 919 718 0000 West 909 627 9634 Website StaticControl com 16 Enter a line name and then click the OK button 17 The line name will appear on the navigation pane in SMP Server Admin 18 Click on the li...

Page 12: ...mployee Owned SCS 926 JR Industrial Drive Sanford NC 27332 East 919 718 0000 West 909 627 9634 Website StaticControl com 19 The serial number for the WS Aware Monitor will appear Click attach 20 The W...

Page 13: ...ES INC Employee Owned SCS 926 JR Industrial Drive Sanford NC 27332 East 919 718 0000 West 909 627 9634 Website StaticControl com 21 Open SCS SMP Client 22 Verify that the WS Aware Monitor was added to...

Page 14: ...adapter until cleaning is finished Replacing the Operator Remote s Wrist Strap Jacks Should the operator remote s wrist strap jacks begin to show wear and tear damage they can be replaced using the S...

Page 15: ...tions Power Power Adapter 100 240VAC 50 60 Hz Output 7 5VDC 1 5A Output Plug Polarization Center Positive Output Plug 5 5 mm O D x 2 1 mm I D x 9 5 mm L Operator Wrist Strap Dual Wire Amount Monitored...

Page 16: ...le Do not position the monitor accessories or other equipment where unplugging the power supply is difficult Always locate the power source socket or outlet near the equipment The power supply plug se...

Page 17: ...ead mercury hexavalent chromium polybrominated biphenyls or polybrominated diphenyl ethers or b 0 01 by weight for cadmium Unless otherwise stated by SCS in writing this information represents our bes...

Page 18: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information SPI Westek 770061...

Reviews: